Sensor Adapter with Lock Function Enables Safe and Thorough Cleaning
The cleaning of sensors is a central aspect in the monitoring of different process parameters. However, proper cleaning is particularly difficult in wastewater monitoring, where the sensor technology used in the liquid quickly becomes contaminated. Even reach their limits in this case. The new sensor adapter ARD75 with gate function provides a remedy and ensures thorough cleaning without interfering with the process.
Sensor adapter ARD75
In the chemical treatment of, hard means are used. Among other things, companies often use milk of lime to neutralize the very acidic wastewater. The problem is that the sensors, which are supposed to monitor the process in the water itself, can be covered with a layer of lime within a few minutes, This severely impairs the sensor’s function. Until now, users have had several options to counter this problem: They could use the cleaning nozzles of the immersion fittings used, which measure directly in the process. However, cleaning liquid not only splashes against the sensor but also enters the process. Another disadvantage is that this way of cleaning is insufficient. For this reason, users have resorted to removing the sensor from the immersion assembly and cleaning it manually. This is very costly and time-consuming. As an alternative, companies could use a retractable fitting, but the investment is associated with higher costs.
Reliable separation of cleaning and process medium
The industry is therefore looking for a way to carry out the sensor cleaning process without manual interruption inside the surrounding medium. The solution lies in a sensor adapter with lock function that works in combination with established immersion fittings: Through the airlock, the cleaning of the sensors takes place completely separated from the medium in a cleaning chamber. Due to the plastic material used, the fitting is metal-free and can thus also be used in highly corrosive processes. No process media can escape from the fitting during the sensor movement. This increases occupational safety in the process and protects the environment.
Safety even in aggressive processes
Users who already use immersion fittings, but are not satisfied with the cleaning performance, benefit most from the sensor adapter with gate function. In addition, the adapter is suitable for use in highly aggressive processes that require very frequent and thorough cleaning of the sensors. The cleaning chamber acts as protection. Users who only use sensors for short-term measurements can keep the sensor safe and cleaned in this chamber during the non-measurement phases. But even if the process must be monitored permanently, the sensor adapter offers the solution: If two sensor adapters are used redundantly, one fitting measures the measured value to be observed while the sensor is cleaned in the second fitting. After a few minutes, the two devices alternate. In this way, even the most persistent lime deposits on sensors in wastewater neutralization can be removed.
Latest Posts
Interface Technology
Hydrogen
Interface Technology
Interface Technology
Exhibition, InnoTrans
Process Analytics
Uniclean700, Launch
Knick GmbH Company | Interface Technology | Process Analytics
Related Posts
Feb 2024
Process Analytics
Uniclean700, Launch
Uniclean 700 Series - Modular control system for automated sensor cleaning
Apr 2023
Process Analytics
Launch, Fitting, WA111
Robust WA111 Retractable Fitting Made of Plastic for Highly Corrosive Operating Conditions
Apr 2023
Process Analytics
Launch, Fitting, WA155
Successful joint project : Knick developed the special Ceramat WA 155 retractable fitting for optical probes from SOPAT
Apr 2023
Process Analytics
Conductivity, Phamacy, pH
pH and conductivity measurement in vaccine production
Apr 2023
Process Analytics
Conductivity, Sensor, SE625
Sturdy 2-Electrodes Conductivity Sensor SE625 with Coaxial Electrodes made of Titanium
Jan 2023
Process Analytics
ARD75
Sensor Adapter with Lock Function Enables Safe and Thorough Cleaning
Nov 2022
Process Analytics
Protos II 4400, Module
Up to six Sensors on one Transmitter Protos II 4400 via Modul MSU4400-180
Aug 2022
Process Analytics
Exhibition, Achema
ACHEMA 2022 - Knick at the world forum for the process industry
Jun 2022
Process Analytics
pH, Sensor, SE555, ORP
Combined pH- and ORP-Sensor SE555X/*-AMSN
Apr 2022
Process Analytics
MemoTrans
Ultra Compact Transmitter for Memosens Sensors
Feb 2022
Process Analytics
Protos II 4400, Stratos Multi, Software, ProgaLog
Conveniently configure transmitters offline on a PC - ProgaLog 4000
Feb 2022
Process Analytics
Stratos Multi, Transmitter
New Stratos Multi E461N transmitter with Profinet
Jan 2022
Process Analytics
Memosens
Memosens 2.0: Evolution of digital data transfer
Nov 2021
Process Analytics
Conductivity, Sensor, Ex, SE656, SE655
SE655X Digital and SE656X Digital - Digital Conductivity Sensors with Ex Certification
Nov 2021
Process Analytics
Exhibition, Switzerland, Ilmac
ILMAC 2021 in Basel - Trade Show Review by Knick Schweiz AG
Oct 2021
Process Analytics
Stratos Multi, Transmitter, Ex
Stratos Multi E401X- Multiparameter Transmitter for Hazardous Locations
May 2021
Process Analytics
Transmitters, Stratos Multi
Stratos Multi E471 with EtherNet/IP for process optimization
May 2021
Process Analytics
Launch, Conductivity, Sensor, SE656
New SE656N digital conductivity sensor
Mar 2021
Process Analytics
Protos II 4400, Profinet
Transmitter for the process industry with PROFINET module
Jul 2020
Process Analytics
Launch, Fitting, ARD170
High-quality immersion fitting for mobile applications
Jul 2020
Process Analytics
Fitting, ARD50, ARD75
Modular immersion fitting as an electrically conductive variant
Apr 2020
Process Analytics
Launch, Transmitters, Stratos Multi
New multiparameter transmitter Stratos Multi
Feb 2018
Process Analytics
Fitting, Sensor
How to get the sensor into the process
Apr 2017
Process Analytics
MemoRail Modbus
Powerful compact analyzer boosts performance while reducing costs
Feb 2017
Process Analytics
Conductivity
High-Precision Conductivity Measurement at Extreme Temperature Differences
Nov 2016
Process Analytics
Transmitter, FF, Profibus, HART