Successful joint project : Knick developed the special Ceramat WA 155 retractable fitting for optical probes from SOPAT
Automatic cleaning of optical probes in adapted Ceramat retractable fitting
Optical probes, such as those supplied by instrumentation firm SOPAT in Berlin, are relatively heavy, particularly when used in ATEX applications, and, on processes that tend to produce fouling, require complex cleaning of the probe window to ensure uninterrupted measurements. To fully automate this cleaning process, Knick worked to adapt its Ceramat retractable fitting in a cooperation arrangement with SOPAT.
We are delighted to announce that we can now offer probes together with a premium fitting.
We were happy to take on the challenge of adapting our fitting to match these specific requirements.
Fitting adapted on cooperation project
Fitting adapted on cooperation projectFitting adapted on cooperation projectThe idea of joining forces arose in the context of a specific project from a customer in the chemical industry who wanted to use a SOPAT probe for their application. “The weight of the SOPAT probes compared to O2 or pH probes was the biggest challenge,” says Rohloff, who supervised the project at Knick: “If the probe is installed horizontally, we have high leverage forces to contend with.” In order to withstand these forces, the developers at Knick modified the bearing of the Ceramat, and within just a few months, the revised fitting was able to prove its worth on the customer’s project. Wegener is pleased: “The Ceramat WA 155 has provided us with a fully-automated solution that allows us to use our probes under even difficult process conditions, without the need to remove them for cleaning. An excellent spirit of cooperation with Knick was the key to the rapid project turnaround.”
Complete system enables automatic cleaning
In combination with the Ceramat retractable fitting and the Uniclean 900 electro-pneumatic controller from Knick, the SOPAT probe can be cleaned entirely automatically without having to interrupt the process. The probe is retracted by the fitting and separated from the process. The probe window is then rinsed with various cleaning solutions and dried with compressed air. All this is done without any user intervention – the probe is immediately ready for use again and can be moved back into the process via the Ceramat.
Latest Posts
Interface Technology
Hydrogen
Interface Technology
Interface Technology
Exhibition, InnoTrans
Process Analytics
Uniclean700, Launch
Knick GmbH Company | Interface Technology | Process Analytics
More information in our Flyer: Optical probes in combination with Knick Ceramat WA155
Assigned Products
WA130
Related Posts
Feb 2024
Process Analytics
Uniclean700, Launch
Uniclean 700 Series - Modular control system for automated sensor cleaning
Apr 2023
Process Analytics
Launch, Fitting, WA111
Robust WA111 Retractable Fitting Made of Plastic for Highly Corrosive Operating Conditions
Apr 2023
Process Analytics
Launch, Fitting, WA155
Successful joint project : Knick developed the special Ceramat WA 155 retractable fitting for optical probes from SOPAT
Apr 2023
Process Analytics
Conductivity, Phamacy, pH
pH and conductivity measurement in vaccine production
Apr 2023
Process Analytics
Conductivity, Sensor, SE625
Sturdy 2-Electrodes Conductivity Sensor SE625 with Coaxial Electrodes made of Titanium
Jan 2023
Process Analytics
ARD75
Sensor Adapter with Lock Function Enables Safe and Thorough Cleaning
Nov 2022
Process Analytics
Protos II 4400, Module
Up to six Sensors on one Transmitter Protos II 4400 via Modul MSU4400-180
Aug 2022
Process Analytics
Exhibition, Achema
ACHEMA 2022 - Knick at the world forum for the process industry
Jun 2022
Process Analytics
pH, Sensor, SE555, ORP
Combined pH- and ORP-Sensor SE555X/*-AMSN
Apr 2022
Process Analytics
MemoTrans
Ultra Compact Transmitter for Memosens Sensors
Feb 2022
Process Analytics
Protos II 4400, Stratos Multi, Software, ProgaLog
Conveniently configure transmitters offline on a PC - ProgaLog 4000
Feb 2022
Process Analytics
Stratos Multi, Transmitter
New Stratos Multi E461N transmitter with Profinet
Jan 2022
Process Analytics
Memosens
Memosens 2.0: Evolution of digital data transfer
Nov 2021
Process Analytics
Conductivity, Sensor, Ex, SE656, SE655
SE655X Digital and SE656X Digital - Digital Conductivity Sensors with Ex Certification
Nov 2021
Process Analytics
Exhibition, Switzerland, Ilmac
ILMAC 2021 in Basel - Trade Show Review by Knick Schweiz AG
Oct 2021
Process Analytics
Stratos Multi, Transmitter, Ex
Stratos Multi E401X- Multiparameter Transmitter for Hazardous Locations
May 2021
Process Analytics
Transmitters, Stratos Multi
Stratos Multi E471 with EtherNet/IP for process optimization
May 2021
Process Analytics
Launch, Conductivity, Sensor, SE656
New SE656N digital conductivity sensor
Mar 2021
Process Analytics
Protos II 4400, Profinet
Transmitter for the process industry with PROFINET module
Jul 2020
Process Analytics
Launch, Fitting, ARD170
High-quality immersion fitting for mobile applications
Jul 2020
Process Analytics
Fitting, ARD50, ARD75
Modular immersion fitting as an electrically conductive variant
Apr 2020
Process Analytics
Launch, Transmitters, Stratos Multi
New multiparameter transmitter Stratos Multi
Feb 2018
Process Analytics
Fitting, Sensor
How to get the sensor into the process
Apr 2017
Process Analytics
MemoRail Modbus
Powerful compact analyzer boosts performance while reducing costs
Feb 2017
Process Analytics
Conductivity
High-Precision Conductivity Measurement at Extreme Temperature Differences
Nov 2016
Process Analytics
Transmitter, FF, Profibus, HART