Skip to main content

A21000 Isolated Standard Signal Conditioner | Input and Output 0(4) … 20 mA or 0 … 10 V | Isolation up to 300 V

Description

A21000 Isolated Standard Signal Conditioner | Input and Output 0(4) … 20 mA or 0 … 10 V | Isolation up to 300 V

The first standard-signal isolation amplifier with broad-range power supply in the 6-mm class.

  • Broad-range power supply 
    24 to 110 V DC (+/-25 %) and 110 to 230 V AC (+/-10 %)
  • Standards-compliant personal and plant protection
    Protective separation according to EN 61140"
  • 3-port isolation
    Prevention of incorrect measure-ments caused by potential differences
  • Ideal value for money
    High accuracy and isolation – 2.5 kV AC test voltage
  • Easy installation
    DIN rail bus connectors allow for easy and extremely cost efficient connection of the power supply to several A21000 or other Knick products in 6 mm housings.
  • Cost reduction with smaller enclosure
    More channels per meter DIN rail thanks to space-saving 6 mm housing and closely packed mounting
  • Long service life
    Extremely low failure rate  (MTBF of 280 years) due to reduced self-heating
  • High accuracy and temperature stability
    Gain error 0.2 % and temperature coefficient 0.01 %/K
  • Calibrated range selection 
    without complicated readjustments
  • Easy configuration
    DIP switch accessible from outside
  • Adjustable or fixed-range models
  • 5-year warranty

The A21000 isolates, transmits and converts 0 to 20/4 to 20 mA and 0 to 10 V with a high level of accuracy. In spite of its modular housing being only 6 mm wide, the new isolation amplifier provides maximum protection of personnel and equipment through protective separation up to a working voltage of 300 V conforming to EN 61140. The test voltage is 2.5 kV AC. It can be supplied with either 24 V DC or 230 V AC.

We look forward to hearing from you!
Contact Us

Technical details

Function: Transmission / Insulation / Conversion of standard signals
Input: 0 ... 10 V, 0 ... 20 mA, 4 ... 20 mA
Output: 0 ... 10 V, 0 ... 20 mA, 4 ... 20 mA
Isolation AC/DC: up to 300 V
Test Voltage: 2.5 kV AC
Power Supply: 24 ... 110 V DC, 110 ... 230 V AC
Cutoff Frequency: 100 Hz
Ambient operating temperature: 0 … 55 °C
Dimensions (W x L x H): 6.2 x 93 x 101 mm
Special features: Extraordinary operating time and reliability with specially adapted design. MTBF (mean time between failures): 280 years, The first standard-signal conditioner with protective separation and broad-range power supply in the 6 mm class
Product Category: Isolated Signal Conditioner

Downloads

Manuals

[380] User Manual (DE, EN)
A21000
Version 01
[13390] User Manual (DE, EN, FR, ES)
ZU 0677 (Power terminal block)
Version 03

Brochures

[14160] Brochure
Product Overview Interface Technology

Data Sheets

[371] Data sheet
A21000
Product Description | Specifications | Product Range

Certificates

[11500] EU Declaration of Conformity (DE, EN, FR)
No. EU210121A | 2021-01-21
A210**P0/0

Software

[12154] Software (.zip)
ePLAN P8 Produktmakros
[11876] Knick Produktmakros (.pdf)
ePLAN Electric P8

Our service

Used in Process or Applications

High voltage transducers and signal conditioners for the acquisition and conversion of current, voltage, temperature, speed, strain and resistance signals.

Related Products

Relevant Blog Posts

Knick Products Comply With UL - What Does That Mean?

There are different assessments and approaches to reach an adequate level of safety. Manufacturers are typically on the “safe” side, if they comply with recognized standards.