Universal high voltage transducers. Input voltages up to Vin = ±3600 V.

  • Universal high voltage transducers
    for converting input voltages up to 3600 V AC/DC to impressed ±20 mA, ±10 V, or 4 ... 20 mA output signals
  • TransShield technology
    enables extremely compact modular housings:
    • Working voltages up to 3600 V AC/DC with a housing width of 67.5 mm
    • Working voltages up to 2200 V AC/DC with a housing width of 45 mm
  • Protection against electric shock
    with protective separation up to 1800 V AC/DC according to EN 61140
  • Test voltages up to 15 kV AC
  • Excellent transmission properties:
    • Gain error < 0.3 %
    • Cutoff frequency 5 kHz (low-pass filter / lower cutoff frequency on request)
    • Rise time T90 approx. 110 µs
  • Maximum accuracy
  • Tremendous flexibility provided by
    • Calibrated switching of up to 16 input/output ranges (working voltage up to 2200 V)
    • Up to 16 customer-specific measuring ranges
    • 20 V to 253 V AC/DC broad-range power supply
  • Reliable function
    even with unstable power supply
  • No damage
    in the case of erroneous power connection
  • Switchable models
    minimize required device variants and save stockkeeping costs
  • Suitable for DC railway systems 
    up to 3000 V DC
  • Mechanically stable
    for operation on ships, rail vehicles and land crafts
  • 5-year warranty

The P42000 isolation amplifiers have been specially conceived for measuring high voltages up to 3600 V (DC). They reliably isolate high potentials at the input circuit.

The isolating distances are designed to withstand permanent voltages up to 3600 V AC/DC and fast transients up to 20 kV. Protection against electric shock is achieved through protective separation according to EN 61140 between input and output and power supply.

 

We look forward to hearing from you!
Contact Us

Technical details

Product Category: High Voltage Transducer
Device Type: High Voltage Transducers, Universal Isolated Signal Conditioners
Input: (±)500 mV ... (±)200 V, > (±)200 V
Output: 0 … 10 V, 0 … 20 mA, 4 … 20 mA, Others, ±10 V, ±20 mA
Working Voltage, Min.: 50 V, 300 V, 1000 V, 2000 V, 3600 V
Fault Class: < 0.5 %
Housing: 17.5 … 67.5 mm Modular housing
Power Supply: 24 V AC, 24 V DC, 110 / 115 V AC, 220 / 230 V AC, Broad-range power supply, Others
Approvals: CSA, UL

Downloads

Brochures

FLY_EN_ProLine_P42000D2_201102-9203723
[18000] Brochure
Precision Devices for the Rail Industry

Data Sheets

[1513] Data Sheet
VariTrans P 41000, P 42000 (inkl. D2), P 43000
Product Description | Specifications | Product Range

Certificates

[12071] Certificate of Compliance (UL)
No. 20170822-E356768 | 2017-08-22
MOTOR CONTROLLER ACCESSORIES OVER 1500 VOLTS
Series P4x000 / P442xx / P5xxxx
[11463] EU Declaration of Conformity (DE, EN, FR)
Series VariTrans P4x000 (D*-nnnn/D*AG-nnnn/D*TRMS-nnnn)
No. EU221209A | 2023-11-29
[14140] Quality Report (MTBF)
Document No. TX180416A
Failure Rate of Series P40000

Our service

Lorem lorem ipsum ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet. Lorem ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet.

Used in Process or Applications

During battery tests, the charging and discharging operations (battery cycles) are continuously simulated in a HIL (hardware in the loop) configuration that corresponds to the typical use profiles when the electric vehicle is in operation. In the process, a series of parameters are measured, including capacity, battery efficiency, and self-discharging.

Related Products

Relevant Blog Posts

Knick Austria - direct customer contact in Austria from 2024

Reorganization of sales in Austria and new contacts in the field of process analytics and interface technology

InnoTrans 2022 - three products as world firsts for rolling stock and DC traction power supply applications

At InnoTrans 2022 Knick presented 3 products as world firsts for rolling stock and DC traction power supply applications.

Energy storage - the handshake between renewable energy and electric vehicles

Energy storage technology such as battery and hydrogen are critical for growth and continuous development of renewable energy and e-mobility.

P52000VPD voltage presence detector reliably detects voltages up to 4200 V DC

The new P52000VPD voltage presence detector reliably monitors areas with high voltages and sends a signal to the downstream plant control system when a specified threshold value is reached.

Knick Interface at Battery and Electric & Hybrid Vehicle Technology Expo

Knick will be showcasing high-voltage electrical measurement and signal conversion products.

Quadruple Standard Signals in Just One Signal Conditioner

The A20340 can output a standard input signal to four calibrated and galvanically isolated outputs in parallel.

Electrical measurement and process analytics for hydrogen production

Knick products optimize hydrogen production in the process and in electrolyser operation.

Condition Monitoring of High-Voltage Motors

Having an active predictive maintenance campaign in place for large rotating equipment can be a key strategy for maximizing process uptime.

Pulse frequency conditioner for speed sensors

The new P16000 from Knick is a pulse frequency conditioner that converts frequency signals from speed sensors into standard signals.

Worldwide smallest transducer up to ±2200 V

The P40000 series from Knick enables reliable voltage measurements from ±50 mV to ±3600 V and current measurements from ±100 mA to ±20 kA.

Importance of broad-range power supplies for DC electrical measurement

Many DC electrical measurement products manufactured by Knick contain universal, also known as broad-range, power supplies.

Measuring Photovoltaic Degradation

Photovoltaic (PV) array degradation is an important aspect to consider for system design and installation.

Electrical Measurement Solutions: Control from 480 to 4800 Volts

Voltage and current transducers from Knick bring true control to electrical measurement applications across a wide-range of industries.

Benefits of High Voltage Transducers versus Instrument Transformers

When a need arises to step voltage in a circuit either up or down for purposes of power transmission or distribution, there is no doubt that transformers are essential.

Shunt Resistor versus Hall Effect Technology

There are many systems where measurement of large DC currents are needed for performance and safety.

MTBF beyond 3000 years: A snap hook for your plant

Failure of equipment on the plant floor can lead to considerable and costly disruption.

Knick Products Comply With UL - What Does That Mean?

There are different assessments and approaches to reach an adequate level of safety. Manufacturers are typically on the “safe” side, if they comply with recognized standards.

High-voltage transducer offers more safety on railway vehicles

The requirements placed on railway vehicles have increased significantly in recent years. Products for rolling stock need to ensure a higher level of functional safety than ever before.

True RMS Measurement with P41000TRMS

Traditional millivolt AC transducers are very susceptible to errors due to their poor insulation and are only designed for pure sinewave measurement.

Functional safety and maximum availability can go together

The requirements on operational and safety-related circuits are continuously growing.