  • Voltage measurement up to 4800 V with calibrated switching of measuring ranges
  • Short circuit recognition
  • Monitoring and control of traction motors and converters
  • Rated isolation voltage up to 4800 V AC/DC
  • Housing offers protection against contact and pollution for added safety
  • Circuit monitoring with self-diagnostics
  • Selectable input ranges and floating standard signal outputs for flexible, easy system integration
  • Integrated broad-range power supply
  • Resistant in tough conditions: extreme temperatures, shock, vibration and harsh EMC environments

Maximum flexibility is achieved through a new housing concept — specifically designed for rolling stock. With integrated broadrange power supply and a unique combination of safety functions.

Electric as well as diesel-electric locomotives and multiple units (EMU/DEMU) require multifold monitoring and control of electric energy. Voltage and current sensors used for this purpose need to meet the special demands posed by railway operations.

Of particular concern are fire and smoke protection, electrical safety, as well as robustness towards extreme environmental conditions, mechanical stress and EMI influences.

The P50000 transducer series was specifically designed for applications on locomotives and multiple units for short circuit recognition, monitoring and control of traction motors and converters, auxiliary converters, accumulator batteries and others. A brand new feature is the flexibility provided by switchable measuring ranges and an integrated broad-range power supply.

Comprehensive certifications and conformity with railway standards make the devices the ideal choice for railway applications.

We look forward to hearing from you!
Contact Us

Technical details

Function: High voltage measurement
Input: 0 ... (±)100 V up to 0 ... (±)4800 V
Output: 0 ... (±)5 V, 0 ... (±)10 V, 0 ... (±)20 mA, 4 ... 20 mA
Isolation AC/DC: up to 4,800 V
Test Voltage: 12/18 kV AC
Power Supply: 24 ... 230 V AC/DC
Cutoff Frequency: Switchable cutoff frequency 9 kHz (P52x00) and 10 Hz, other cutoff frequency on request
Ambient operating temperature: –40 ... 85 °C
Dimensions (W x L x H): 72.5 x 182 x 116 mm
Special features: 10 thresholds adjustable via rotary switch for VPD, Diagnostics of input/output circuits and device function, Energy metering (EN 50463), For use on rolling stock (EN 50155)
Standards: EN 45545-2, EN 50155:2021, EN 50463
Product Category: High Voltage Transducer

Downloads

Manuals

[13370] User Manual (DE, EN, FR)
P50000
Transducers for High Voltage and Current Measurement
Version 02

Brochures

[18000] Brochure
Precision Devices for the Rail Industry

Data Sheets

[13380] Data Sheet
P50000
Product Description | Specifications | Product Range

Certificates

[13622] EU Declaration of Conformity (DE, EN, FR)
No. EU210121B | 2021-01-21
Transducer P51000, P52000
[13994] Certificate TÜV Süd
Tested according to: EN 50155:2021 and EN 45545-2:2020
Types ProLine P51000K, P51100K, P52000K, P52100K
Test report no.: KB102157T | 2024-05-10
[14170] Intermediate Statement of Verification
EC Type Examination
Subsystem: Rolling Stock
Series P51x00K11, Series P52x00K11
[12071] Certificate of Compliance (UL)
P41000, P42000, P43000, P44200, P51000, P52000
MOTOR CONTROLLER ACCESSORIES OVER 1500 VOLTS
No. UL-US-L356768-11-22503102-1 | 202406-28

Our service

Used in Process or Applications

The electrical measuring technology from Knick provides a range of solutions for signal detection and conversion, current and voltage measurement, and more.

Related Products

Relevant Blog Posts

Stack and String Voltage Measurement in Electrolyzers and Fuel Cells

Voltage, current and temperature measurement in electrolyzers with P40000 series high voltage transducers

New 30 mV Shunt Resistors for Knick Transducers

Knick is expanding the accessory range for its high-voltage transducers with immediate effect by adding shunt resistors with a 30 mV voltage drop
Innovations at InnoTrans 2024

Innovations at InnoTrans 2024 for rolling stock and DC traction power supply

At InnoTrans 2024 Knick presents electrical measurement solutions for rolling stock and DC traction power supply applications

Knick Austria - direct customer contact in Austria from 2024

Reorganization of sales in Austria and new contacts in the field of process analytics and interface technology

Energy storage - the handshake between renewable energy and electric vehicles

Energy storage technology such as battery and hydrogen are critical for growth and continuous development of renewable energy and e-mobility.

P52000VPD voltage presence detector reliably detects voltages up to 4200 V DC

The new P52000VPD voltage presence detector reliably monitors areas with high voltages and sends a signal to the downstream plant control system when a specified threshold value is reached.

Knick Interface at Battery and Electric & Hybrid Vehicle Technology Expo

Knick will be showcasing high-voltage electrical measurement and signal conversion products.

Quadruple Standard Signals in Just One Signal Conditioner

The A20340 can output a standard input signal to four calibrated and galvanically isolated outputs in parallel.

Electrical measurement and process analytics for hydrogen production

Knick products optimize hydrogen production in the process and in electrolyser operation.

Condition Monitoring of High-Voltage Motors

Having an active predictive maintenance campaign in place for large rotating equipment can be a key strategy for maximizing process uptime.

Pulse frequency conditioner for speed sensors

The new P16000 from Knick is a pulse frequency conditioner that converts frequency signals from speed sensors into standard signals.

Worldwide smallest transducer up to ±2200 V

The P40000 series from Knick enables reliable voltage measurements from ±50 mV to ±3600 V and current measurements from ±100 mA to ±20 kA.

Importance of broad-range power supplies for DC electrical measurement

Many DC electrical measurement products manufactured by Knick contain universal, also known as broad-range, power supplies.

Measuring Photovoltaic Degradation

Photovoltaic (PV) array degradation is an important aspect to consider for system design and installation.

Electrical Measurement Solutions: Control from 480 to 4800 Volts

Voltage and current transducers from Knick bring true control to electrical measurement applications across a wide-range of industries.

Benefits of High Voltage Transducers versus Instrument Transformers

When a need arises to step voltage in a circuit either up or down for purposes of power transmission or distribution, there is no doubt that transformers are essential.

Shunt Resistor versus Hall Effect Technology

There are many systems where measurement of large DC currents are needed for performance and safety.

MTBF beyond 3000 years: A snap hook for your plant

Failure of equipment on the plant floor can lead to considerable and costly disruption.

Knick Products Comply With UL - What Does That Mean?

There are different assessments and approaches to reach an adequate level of safety. Manufacturers are typically on the “safe” side, if they comply with recognized standards.

High-voltage transducer offers more safety on railway vehicles

The requirements placed on railway vehicles have increased significantly in recent years. Products for rolling stock need to ensure a higher level of functional safety than ever before.

True RMS Measurement with P41000TRMS

Traditional millivolt AC transducers are very susceptible to errors due to their poor insulation and are only designed for pure sinewave measurement.

Functional safety and maximum availability can go together

The requirements on operational and safety-related circuits are continuously growing.