Skip to main content

WG25 Repeater Power Supply | Input 4 … 20 mA | Ex | Transmission of HART signals

Description

WG25 Repeater Power Supply | Input 4 … 20 mA | Ex | Transmission of HART signals

For supply of intrinsically safe 2-wire transmitters and SMART transmitters.

  • Affordable
    Good price due to omission of integrated power supply
  • No mains supply required
    Cost savings due to lower wiring effort, no mains influences
  • Low power losses
    No unnecessary heating in the enclosure
  • Protective separation
    according to EN 61140 Protection of maintenance staff and downstream devices against excessively high voltages
  • HART transmission
    Bidirectional point-to-point transmission of digital data according to the HART specification
  • EMC tested
    RFI suppressed and surge proof, reliable operation even with electromagnetic interference
  • Maximum reliability
    No maintenance work, therefore the related costs are not incurred

The Task
The passive WG25 repeater power supply is loop-powered. It is used for galvanic hazardous-area separation of a 2-wire supply line and transmits both 4 ... 20 mA and HART signals in both directions. With a voltage drop of just 4.2 V, the WG 25 uses the supply optimally so that all common 2-wire transmitters can be connected.

The Advantages
Compared with active repeater power supplies, it has considerable price and reliability advantages. 
Multi-channel systems, for example, require only one central, safe-area power supply that does not even need protective separation.

The Technology
Using Knick TransShield technology, the WG25 has specifications that were previously not available in passive repeater power supplies:

  • Extremely high reliability, MTTF of over 300 years
  • Protective separation, transient protection
  • 10 kV test voltage (optional)
  • High electromagnetic compatibility
  • Extremely low residual ripple and common-mode interference
  • Outstanding pulse formation
  • HART transmission
  • Hazardous/safe area separation

We look forward to hearing from you!
Contact Us

Technical details

Communication (Output, Digital): HART
Explosion protection: Ex
Product Category: Isolated Signal Conditioner

Downloads

Manuals

[4502] User Manual (DE, EN)
WG 25
Loop-Powered Supply
Version 04

Data Sheets

[4397] Data Sheet
WG25
Product Description | Specifications | Product Range

Certificates

[13687] EU Declaration of Conformity (DE, EN, FR)
WG 25 A7, Opt. ... & IsoTrans 37 A7, Opt. ...
No. EU210416A | 2021-04-16
WG25_37A7__PTB 02 ATEX 2063_Ausgabe1_e-4937197

Our service

Used in Process or Applications

High voltage transducers and signal conditioners for the acquisition and conversion of current, voltage, temperature, speed, strain and resistance signals.

Related Products

Relevant Blog Posts

Stack and String Voltage Measurement in Electrolyzers and Fuel Cells

Voltage, current and temperature measurement in electrolyzers with P40000 series high voltage transducers

New 30 mV Shunt Resistors for Knick Transducers

Knick is expanding the accessory range for its high-voltage transducers with immediate effect by adding shunt resistors with a 30 mV voltage drop
Innovations at InnoTrans 2024

Innovations at InnoTrans 2024 for rolling stock and DC traction power supply

At InnoTrans 2024 Knick presents electrical measurement solutions for rolling stock and DC traction power supply applications

Knick Austria - direct customer contact in Austria from 2024

Reorganization of sales in Austria and new contacts in the field of process analytics and interface technology

Energy storage - the handshake between renewable energy and electric vehicles

Energy storage technology such as battery and hydrogen are critical for growth and continuous development of renewable energy and e-mobility.

P52000VPD voltage presence detector reliably detects voltages up to 4200 V DC

The new P52000VPD voltage presence detector reliably monitors areas with high voltages and sends a signal to the downstream plant control system when a specified threshold value is reached.

Knick Interface at Battery and Electric & Hybrid Vehicle Technology Expo

Knick will be showcasing high-voltage electrical measurement and signal conversion products.

Quadruple Standard Signals in Just One Signal Conditioner

The A20340 can output a standard input signal to four calibrated and galvanically isolated outputs in parallel.

Electrical measurement and process analytics for hydrogen production

Knick products optimize hydrogen production in the process and in electrolyser operation.

Condition Monitoring of High-Voltage Motors

Having an active predictive maintenance campaign in place for large rotating equipment can be a key strategy for maximizing process uptime.

Pulse frequency conditioner for speed sensors

The new P16000 from Knick is a pulse frequency conditioner that converts frequency signals from speed sensors into standard signals.

Worldwide smallest transducer up to ±2200 V

The P40000 series from Knick enables reliable voltage measurements from ±50 mV to ±3600 V and current measurements from ±100 mA to ±20 kA.

Importance of broad-range power supplies for DC electrical measurement

Many DC electrical measurement products manufactured by Knick contain universal, also known as broad-range, power supplies.

Measuring Photovoltaic Degradation

Photovoltaic (PV) array degradation is an important aspect to consider for system design and installation.

Electrical Measurement Solutions: Control from 480 to 4800 Volts

Voltage and current transducers from Knick bring true control to electrical measurement applications across a wide-range of industries.

Benefits of High Voltage Transducers versus Instrument Transformers

When a need arises to step voltage in a circuit either up or down for purposes of power transmission or distribution, there is no doubt that transformers are essential.

Shunt Resistor versus Hall Effect Technology

There are many systems where measurement of large DC currents are needed for performance and safety.

MTBF beyond 3000 years: A snap hook for your plant

Failure of equipment on the plant floor can lead to considerable and costly disruption.

Knick Products Comply With UL - What Does That Mean?

There are different assessments and approaches to reach an adequate level of safety. Manufacturers are typically on the “safe” side, if they comply with recognized standards.

High-voltage transducer offers more safety on railway vehicles

The requirements placed on railway vehicles have increased significantly in recent years. Products for rolling stock need to ensure a higher level of functional safety than ever before.

True RMS Measurement with P41000TRMS

Traditional millivolt AC transducers are very susceptible to errors due to their poor insulation and are only designed for pure sinewave measurement.

Functional safety and maximum availability can go together

The requirements on operational and safety-related circuits are continuously growing.