Skip to main content

CONDI 3400X-051 Inductive Conductivity Measuring Module | For Protos | Analog Toroidal Sensors | Ex

Description

CONDI 3400X-051 Inductive Conductivity Measuring Module | For Protos | Analog Toroidal Sensors | Ex
  • Toroidal sensors
  • Sensocheck sensor monitoring
  • Sensor monitor
  • Can be used universally for many commercial toroidal conductivity sensors, adaptation via sensor ID

We look forward to hearing from you!
Contact Us

Technical details

Measurement Parameter: Conductivity (inductive)
Sensors: Toroidal sensors
Explosion protection: Ex

Downloads

Manuals

[14565] Installation Guide
Measuring Module Protos CONDI 3400(X)-051
Protos II 4400(X) / Protos 3400(X)
Version 02
[1217] User Manual
Measuring Module Protos CONDI 3400(X)-051
for Protos II 4400(X) / Protos 3400 (X)
Version 10
[1217] Betriebsanleitung
Messmodul Protos CONDI 3400(X)-051
für Protos II 4400(X) / Protos 3400 (X)
Version 10

Certificates

[7018] IECEx Certificate of Conformity
No. IECEx DEK 11.0054 | 2022-07-28
3400X, Protos II 4400X & Module
Issue No. 5
[14326] EU Type-Examination Certificate
No. KEMA 03ATEX2530 | 2022-07-28 | Issue No. 11
Protos 3400X, Protos II 4400X & Modules
[16755] Certificate of Conformity (FM)
No. FM19US0234X (USA)
Protos 3400X, Protos II 4400X & Module
26 January 2023
[12581] Certitficate of Conformity (China - Ex NEPSI)
Protos 3400X, Protos II 4400X & Module
Cert No. GYJ20.1054 | 2025-08-19
[18017] Certitficate of Conformity (China - Ex NEPSI)
Protos 3400X, Protos II 4400X, Module und MSU 4400X-180 Module
Cert No. GYJ20.1054 | 2025-08-19
[16762] Certificate of Conformity (FM)
No. FM19CA0127X (Canada)
Protos 3400X, Protos II 4400X & Module
26 January 2023
[14655] EU Declaration of Conformity (DE, EN, FR)
Protos Type 3400X*/***& Protos II Type 4400X*/***
No. EU221019A | 2022-10-19

Control Drawings

[16770] Control Drawing
Protos 3400X, Protos II 4400X & Modules
Zeichnungsnummer 201.003-170 page 1 rev.4
cFMus

Our service

Used in Process or Applications

Knick offers innovative process analyzers, high quality holders and fittings, and unique cleaning and calibration systems

Related Products

Relevant Blog Posts

Stack and String Voltage Measurement in Electrolyzers and Fuel Cells

Voltage, current and temperature measurement in electrolyzers with P40000 series high voltage transducers

New 30 mV Shunt Resistors for Knick Transducers

Knick is expanding the accessory range for its high-voltage transducers with immediate effect by adding shunt resistors with a 30 mV voltage drop
Innovations at InnoTrans 2024

Innovations at InnoTrans 2024 for rolling stock and DC traction power supply

At InnoTrans 2024 Knick presents electrical measurement solutions for rolling stock and DC traction power supply applications

Knick Austria - direct customer contact in Austria from 2024

Reorganization of sales in Austria and new contacts in the field of process analytics and interface technology

Energy storage - the handshake between renewable energy and electric vehicles

Energy storage technology such as battery and hydrogen are critical for growth and continuous development of renewable energy and e-mobility.

P52000VPD voltage presence detector reliably detects voltages up to 4200 V DC

The new P52000VPD voltage presence detector reliably monitors areas with high voltages and sends a signal to the downstream plant control system when a specified threshold value is reached.

Knick Interface at Battery and Electric & Hybrid Vehicle Technology Expo

Knick will be showcasing high-voltage electrical measurement and signal conversion products.

Quadruple Standard Signals in Just One Signal Conditioner

The A20340 can output a standard input signal to four calibrated and galvanically isolated outputs in parallel.

Electrical measurement and process analytics for hydrogen production

Knick products optimize hydrogen production in the process and in electrolyser operation.

Condition Monitoring of High-Voltage Motors

Having an active predictive maintenance campaign in place for large rotating equipment can be a key strategy for maximizing process uptime.

Pulse frequency conditioner for speed sensors

The new P16000 from Knick is a pulse frequency conditioner that converts frequency signals from speed sensors into standard signals.

Worldwide smallest transducer up to ±2200 V

The P40000 series from Knick enables reliable voltage measurements from ±50 mV to ±3600 V and current measurements from ±100 mA to ±20 kA.

Importance of broad-range power supplies for DC electrical measurement

Many DC electrical measurement products manufactured by Knick contain universal, also known as broad-range, power supplies.

Measuring Photovoltaic Degradation

Photovoltaic (PV) array degradation is an important aspect to consider for system design and installation.

Electrical Measurement Solutions: Control from 480 to 4800 Volts

Voltage and current transducers from Knick bring true control to electrical measurement applications across a wide-range of industries.

Benefits of High Voltage Transducers versus Instrument Transformers

When a need arises to step voltage in a circuit either up or down for purposes of power transmission or distribution, there is no doubt that transformers are essential.

Shunt Resistor versus Hall Effect Technology

There are many systems where measurement of large DC currents are needed for performance and safety.

MTBF beyond 3000 years: A snap hook for your plant

Failure of equipment on the plant floor can lead to considerable and costly disruption.

Knick Products Comply With UL - What Does That Mean?

There are different assessments and approaches to reach an adequate level of safety. Manufacturers are typically on the “safe” side, if they comply with recognized standards.

High-voltage transducer offers more safety on railway vehicles

The requirements placed on railway vehicles have increased significantly in recent years. Products for rolling stock need to ensure a higher level of functional safety than ever before.

True RMS Measurement with P41000TRMS

Traditional millivolt AC transducers are very susceptible to errors due to their poor insulation and are only designed for pure sinewave measurement.

Functional safety and maximum availability can go together

The requirements on operational and safety-related circuits are continuously growing.