Product added to compare
Product Compare added Product Compare

SE555 pH/ORP Sensor | Memosens | 225 mm | Ex | CIP/SIP capable | Sterilizable | For aggressive media

Description

SE555 pH/ORP Sensor | Memosens | 225 mm | Ex | CIP/SIP capable | Sterilizable | For aggressive media

Steam-sterilizable sensor providing high reliability and precision, digital, with Memosens technology

  • Simultaneous measurement of pH and ORP
  • Gel electrolyte, pressurized and long-term stable
  • Ceramic junction
  • Silver ion trap
  • Integrated temperature detector
  • Omega glass with high impedance for high-temperature applications, very low alkali error
  • CIP/SIP capable, safe sterilization with temperature monitoring
  • Perfect galvanic isolation thanks to Memosens technology
  • No influence of humidity in the connector
  • Precalibration in the lab
  • Digital data transfer
  • Integrated sensor diagnostics

The digital pH/ORP sensor SE555X/1-AMSN has a special pH glass with high impedance for high-temperature applications and low alkali error as well as a platinum disk as ORP measuring element.

The sensor is CIP and SIP capable. The silver ion trap prevents contamination and blocking of the junction by silver sulfide in sulfide-containing media. The reference electrolyte is biocompatible. This makes the sensor predestined for applications in food and biotechnology, but it is also suitable for continuous and simultaneous measurement of pH and ORP in process chemistry or wastewater.

In addition, the Memosens technology offers all known advantages in terms of handling and sensor diagnostics.

Applications
Fermentation, food and beverages, aggressive media, extreme pH values, waste water

We look forward to hearing from you!
Contact Us

Technical details

Measurement Parameter: pH/ORP
Connector: Memosens
Explosion protection: Ex
Length: 225 mm
Measuring Range: 0 … 14 pH, ± 1500 mV
Temperature: 0 … 135 °C
Pressure, relative: -1 … 6 bar
Temperature Detector: NTC 30 kΩ
Approvals: FM, IECEx
Junction: Ceramic (1x)
Reference System: Ag/AgCl with silver ion trap
Sensor Material: Omega glass, high impedance, low alkali error, Platinum
Electrolyte: Prepressurized gel electrolyte

Downloads

Manuals

[16286] User Manual (DE, EN, KO)
Memosens Cable CA/MS
Version 09
[12389] User Manual (DE, EN)
SE555X/*-AMSN | -NMSN | -NVPN | -NS8N
Version 04
[14165] User Manual (DE, EN)
ZU 1054 Sensor Protection (Sensorschutz)

Brochures

[13209] Brochure
Memosens - The complete solution for smart sensor applications.
[13395] Brochure
Sensors - For measuring pH/ORP, conductivity or oxygen. Digital or analog.

Data Sheets

[16951] Data sheet
SE555X/*-AMSN Memosens pH/ORP Sensor
Product Description | Specifications | Product Range

Certificates

[11064] EU Declaration of Conformity
No. EU210427A | 2021-04-27
Memosens Sensors | Types SE 5..X..-.MS., SE604X-MS**, SE605….., SE6**X**MS, SE7**…
[14685] Certificate of Conformity (FM)
No. FM17US0208X | 2019-05-27 | USA
Memosens Sensors | Types SE 5**, SE 6** and SE 7**
[12113] Confirmation (DE, EN)
Kein tierischer Ursprung / No components of animal origin
Series SE 555X/*-*MS*, SE555X/*-*VP*, SE 555X/*-*S8
[17427] Type Examination Certificate for Ex-Equipment (Japan)
No. CML 20JPN2077X | from 10-07-2020 to 09-07-2023
MEMOSENS CA/MS-***X**-JP
[12831] IECEx Certificate of Conformity
Memosens Ex Sensors | Details see Document
Document No. IECEx BVS 16.0030X, issue No. 1 | 2021-03-31
Marking: Ex ia IIC T3/T4/T6 Ga
[14690] Certificate of Conformity (FM)
No. FM17CA0105X | 2019-05-27 | Canada
Memosens Sensors | Types SE 5**, SE 6** and SE 7**
[12826] EU-Baumusterprüfbescheinigung (DEKRA)
Nr. BVS 16 ATEX E 037 X | 2021-03-26
Memosens-Ex-Sensoren | Details siehe Dokument
[16292] Korean safety certificate Kosha (KO)
No. 2020-KA4BO-0368X
Measuring Cable CA/MS
[14155] Declaration of Compliance 2.1 (DE, EN)
according to EN 10204 | gemäß EN 10204

Safety guides

[11045] Material Safety Data Sheet
CaliMat buffer solution pH 7,00
[11048] Material Safety Data Sheet
CaliMat buffer solution pH 4,00
[11046] Material Safety Data Sheet
CaliMat buffer solution pH 9,00
[11049] Material Safety Data Sheet
CaliMat buffer solution pH 2,00
[11044] Material Safety Data Sheet
CaliMat buffer solution pH 12,00

Control Drawings

[14185] Control Drawing
Inductive Sensor-Cable Connection System Memosens
Zeichnungsnummer 214.410-240

Our service

Lorem lorem ipsum ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet. Lorem ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet.

Used in Process or Applications

Cooling towers are used in a range of industrial sectors for diverting process heat from cooling circuits. Mineral deposits and corrosion reduce efficiency and lead to the premature wear of system components.
The taste and quality of beer greatly depend on the quality of the water used to brew it. pH and conductivity measurements determine its quality. Globalization is putting massive competitive pressure…
pH sensors are subject to extreme requirements during sugar production. Lime is dosed based on pH measurement right from the start...
Cooling towers are used in a range of industrial sectors for diverting process heat from cooling circuits. Mineral deposits and corrosion reduce efficiency and lead to the premature wear of system components…
High quality requirements are placed on raw milk, and online monitoring of truck unloading procedure at the dairy prevents inferior quality (sour milk) from spoiling the entire stock of the storage tank.

Related Products