Skip to main content

SE565 ORP Sensor | Memosens | 120 mm | Ex | For hygienic processes and sterile applications

Description

SE565 ORP Sensor | Memosens | 120 mm | Ex | For hygienic processes and sterile applications

ORP sensor for hygienic processes and sterile applications.

  • perfect galvanic isolation thanks to Memosens technology
  • no influence of humidity in the connector
  • digital data transfer
  • integrated sensor diagnostics
  • state-of-the-art gel electrolyte
  • integrated temperature detector
  • ceramic junction
  • for hygienic and sterile applications
  • for heavily polluted media
  • for media containing sulfides
  • for media containing proteins
  • suitable for solvent-containing processes

The SE565 ORP sensors are of low maintenance. Through a ceramic junction, the pressurized reference system with gel electrolyte is in contact with the process medium. The measuring electrode is made of platinum.

SE565 sensors are designed for simultaneous measurement of ORP and temperature in industrial processes.

They are suitable for sterilization with steam and they provide a reference system which has been developed for the use in food and pharmaceutical products.

Applications
Hygienic and sterile applications, food and pharmaceutical industry, biotechnology 

We look forward to hearing from you!
Contact Us

Technical details

Measurement Parameter: ORP
Connector: Memosens
Explosion protection: Ex
Length: 120 mm
Process Connection: PG 13.5
Measuring Range: ± 1500 mV
Temperature: 0 … 135 °C
Pressure, relative: -1 … 6 bar
Temperature Detector: NTC 30 kΩ
Junction: Ceramic (1x)
Reference System: Ag/AgCl, pressurized gel electrolyte
Material of measuring electrode: Platinum

Downloads

Manuals

[16286] User Manual (DE, EN, KO)
Memosens Cable CA/MS
Version 09
[14165] User Manual (DE, EN)
ZU 1054 Sensor Protection (Sensorschutz)
[17413] User Manual
SE565X/*-NMSN
incl. Ex Approval Japan (JPEx DEK19.0046X)
[2650] User Manual
SE565 Memosens ORP Sensor
Version 03

Brochures

[13395] Brochure
Sensors - For measuring pH/ORP, conductivity or oxygen. Digital or analog.

Data Sheets

[2645] SE565 Memosens ORP Sensor
Product Description | Specifications | Product Range

Certificates

[14690] Certificate of Conformity (FM)
No. FM17CA0105X | 2019-05-27 | Canada
Memosens Sensors | Types SE 5**, SE 6** and SE 7**
[16639] Type Approval Certificate for Ex-Equipment (JA)
No. DEK19.0046X, Issue No. 0 (Japan)
SE5**X/*-*MSN | SE7**X/*-*MSN
[14685] Certificate of Conformity (FM)
No. FM17US0208X | 2019-05-27 | USA
Memosens Sensors | Types SE 5**, SE 6** and SE 7**
[11064] EU Declaration of Conformity
No. EU210427A | 2021-04-27
Memosens Sensors | Types SE 5..X..-.MS., SE604X-MS**, SE605….., SE6**X**MS, SE7**…
[17541] Korean Safety Certificate
Ex ia IIC T3/T4/T6 Ga / 23-KA4BO-0103X
SE565X**-*MS*, SE571X**-MS**
2023-02-21
[16292] Korean safety certificate Kosha (KO)
No. 2020-KA4BO-0368X
Measuring Cable CA/MS
[12826] EU-Type Examination Certificate (DEKRA)
Nr. BVS 16 ATEX E 037 X | 2024-02-20
Memosens-Ex-Sensors
[14155] Declaration of Compliance 2.1 (DE, EN)
according to EN 10204 | gemäß EN 10204

Control Drawings

[14185] Control Drawing
Inductive Sensor-Cable Connection System Memosens
Zeichnungsnummer 214.410-240

Our service

Used in Process or Applications

In a wide range of industrial sectors, cooling towers are used to dissipate process heat from cooling circuits. Mineral deposits and corrosion reduce their efficiency and lead to premature wear on plant parts.
Reverse osmosis systems are used for water treatment in a wide range of industrial applications. The main application is industrial saltwater desalination.
Accurate measurement of pH values, redox potential, and dissolved oxygen in order to ensure optimal metabolism of the bacteria used in the purification process and in organic wastewater treatment as well, for example.

Related Products

Relevant Blog Posts

Stack and String Voltage Measurement in Electrolyzers and Fuel Cells

Voltage, current and temperature measurement in electrolyzers with P40000 series high voltage transducers

New 30 mV Shunt Resistors for Knick Transducers

Knick is expanding the accessory range for its high-voltage transducers with immediate effect by adding shunt resistors with a 30 mV voltage drop
Innovations at InnoTrans 2024

Innovations at InnoTrans 2024 for rolling stock and DC traction power supply

At InnoTrans 2024 Knick presents electrical measurement solutions for rolling stock and DC traction power supply applications

Knick Austria - direct customer contact in Austria from 2024

Reorganization of sales in Austria and new contacts in the field of process analytics and interface technology

Energy storage - the handshake between renewable energy and electric vehicles

Energy storage technology such as battery and hydrogen are critical for growth and continuous development of renewable energy and e-mobility.

P52000VPD voltage presence detector reliably detects voltages up to 4200 V DC

The new P52000VPD voltage presence detector reliably monitors areas with high voltages and sends a signal to the downstream plant control system when a specified threshold value is reached.

Knick Interface at Battery and Electric & Hybrid Vehicle Technology Expo

Knick will be showcasing high-voltage electrical measurement and signal conversion products.

Quadruple Standard Signals in Just One Signal Conditioner

The A20340 can output a standard input signal to four calibrated and galvanically isolated outputs in parallel.

Electrical measurement and process analytics for hydrogen production

Knick products optimize hydrogen production in the process and in electrolyser operation.

Condition Monitoring of High-Voltage Motors

Having an active predictive maintenance campaign in place for large rotating equipment can be a key strategy for maximizing process uptime.

Pulse frequency conditioner for speed sensors

The new P16000 from Knick is a pulse frequency conditioner that converts frequency signals from speed sensors into standard signals.

Worldwide smallest transducer up to ±2200 V

The P40000 series from Knick enables reliable voltage measurements from ±50 mV to ±3600 V and current measurements from ±100 mA to ±20 kA.

Importance of broad-range power supplies for DC electrical measurement

Many DC electrical measurement products manufactured by Knick contain universal, also known as broad-range, power supplies.

Measuring Photovoltaic Degradation

Photovoltaic (PV) array degradation is an important aspect to consider for system design and installation.

Electrical Measurement Solutions: Control from 480 to 4800 Volts

Voltage and current transducers from Knick bring true control to electrical measurement applications across a wide-range of industries.

Benefits of High Voltage Transducers versus Instrument Transformers

When a need arises to step voltage in a circuit either up or down for purposes of power transmission or distribution, there is no doubt that transformers are essential.

Shunt Resistor versus Hall Effect Technology

There are many systems where measurement of large DC currents are needed for performance and safety.

MTBF beyond 3000 years: A snap hook for your plant

Failure of equipment on the plant floor can lead to considerable and costly disruption.

Knick Products Comply With UL - What Does That Mean?

There are different assessments and approaches to reach an adequate level of safety. Manufacturers are typically on the “safe” side, if they comply with recognized standards.

High-voltage transducer offers more safety on railway vehicles

The requirements placed on railway vehicles have increased significantly in recent years. Products for rolling stock need to ensure a higher level of functional safety than ever before.

True RMS Measurement with P41000TRMS

Traditional millivolt AC transducers are very susceptible to errors due to their poor insulation and are only designed for pure sinewave measurement.

Functional safety and maximum availability can go together

The requirements on operational and safety-related circuits are continuously growing.