Skip to main content

SE565 ORP Sensor | Memosens | 225 mm | Ex | For hygienic processes and sterile applications

Description

SE565 ORP Sensor | Memosens | 225 mm | Ex | For hygienic processes and sterile applications

ORP sensor for hygienic processes and sterile applications.

  • perfect galvanic isolation thanks to Memosens technology
  • no influence of humidity in the connector
  • digital data transfer
  • integrated sensor diagnostics
  • state-of-the-art gel electrolyte
  • integrated temperature detector
  • ceramic junction
  • for hygienic and sterile applications
  • for heavily polluted media
  • for media containing sulfides
  • for media containing proteins
  • suitable for solvent-containing processes

The SE565 ORP sensors are of low maintenance. Through a ceramic junction, the pressurized reference system with gel electrolyte is in contact with the process medium. The measuring electrode is made of platinum.

SE565 sensors are designed for simultaneous measurement of ORP and temperature in industrial processes.

They are suitable for sterilization with steam and they provide a reference system which has been developed for the use in food and pharmaceutical products.

Applications
Hygienic and sterile applications, food and pharmaceutical industry, biotechnology 

We look forward to hearing from you!
Contact Us

Technical details

Measurement Parameter: ORP
Connector: Memosens
Explosion protection: Ex
Length: 225 mm
Process Connection: PG 13.5
Measuring Range: ± 1500 mV
Temperature: 0 … 135 °C
Pressure, relative: -1 … 6 bar
Temperature Detector: NTC 30 kΩ
Junction: Ceramic (1x)
Reference System: Ag/AgCl, pressurized gel electrolyte
Material of measuring electrode: Platinum

Downloads

Manuals

[16286] User Manual (DE, EN, KO)
Memosens Cable CA/MS
Version 09
[14165] User Manual (DE, EN)
ZU 1054 Sensor Protection (Sensorschutz)
[17413] User Manual
SE565X/*-NMSN
incl. Ex Approval Japan (JPEx DEK19.0046X)
[2650] User Manual
SE565 Memosens ORP Sensor
Version 03

Brochures

[13395] Brochure
Sensors - For measuring pH/ORP, conductivity or oxygen. Digital or analog.

Data Sheets

[2645] SE565 Memosens ORP Sensor
Product Description | Specifications | Product Range

Certificates

[14690] Certificate of Conformity (FM)
No. FM17CA0105X | 2019-05-27 | Canada
Memosens Sensors | Types SE 5**, SE 6** and SE 7**
[16639] Type Approval Certificate for Ex-Equipment (JA)
No. DEK19.0046X, Issue No. 0 (Japan)
SE5**X/*-*MSN | SE7**X/*-*MSN
[14685] Certificate of Conformity (FM)
No. FM17US0208X | 2019-05-27 | USA
Memosens Sensors | Types SE 5**, SE 6** and SE 7**
[17541] Korean Safety Certificate
Ex ia IIC T3/T4/T6 Ga / 23-KA4BO-0103X
SE565X**-*MS*, SE571X**-MS**
2023-02-21
[11064] EU Declaration of Conformity
No. EU210427A | 2021-04-27
Memosens Sensors | Types SE 5..X..-.MS., SE604X-MS**, SE605….., SE6**X**MS, SE7**…
[12826] EU-Type Examination Certificate (DEKRA)
Nr. BVS 16 ATEX E 037 X | 2024-02-20
Memosens-Ex-Sensors
[14155] Declaration of Compliance 2.1 (DE, EN)
according to EN 10204 | gemäß EN 10204

Control Drawings

[14185] Control Drawing
Inductive Sensor-Cable Connection System Memosens
Zeichnungsnummer 214.410-240

Our service

Used in Process or Applications

In a wide range of industrial sectors, cooling towers are used to dissipate process heat from cooling circuits. Mineral deposits and corrosion reduce their efficiency and lead to premature wear on plant parts.
Reverse osmosis systems are used for water treatment in a wide range of industrial applications. The main application is industrial saltwater desalination.
Accurate measurement of pH values, redox potential, and dissolved oxygen in order to ensure optimal metabolism of the bacteria used in the purification process and in organic wastewater treatment as well, for example.

Related Products

Relevant Blog Posts

Knick Products Comply With UL - What Does That Mean?

There are different assessments and approaches to reach an adequate level of safety. Manufacturers are typically on the “safe” side, if they comply with recognized standards.