Skip to main content

SE604 2-Electrode Conductivity Sensor | Memosens | Ex | Measuring range from ultrapure water to 500 μS/cm

Description

SE604 2-Electrode Conductivity Sensor | Memosens | Ex | Measuring range from ultrapure water to 500 μS/cm

Robust 2-electrode sensor, for precise and reliable measurement of low and very low conductivities, particularly in ultrapure water, digital, with Memosens technology.

  • Perfect galvanic isolation thanks to Memosens technology
  • Digital data transfer
  • Integrated sensor diagnostics
  • Large measuring range from ultrapure water to 500 μS/cm
  • Coaxially arranged electrodes
  • Independent of installation conditions
  • Integrated temperature detector
  • High level of process safety due to durable materials and robust design
  • Easy to clean thanks to detachable outer electrode
  • Particularly suitable for monitoring ultrapure water in power plants

Robust, coaxially arranged electrodes made of stainless steel. Large measuring range from ultrapure water to 500 μS/cm.

Integrated temperature detector for temperature compensation. Easy to clean thanks to replaceable outer electrode.

Applications
Boiler feed water, feed water, boiler water, cooling water, water vapor cycle, pure water, condenser monitoring

We look forward to hearing from you!
Contact Us

Technical details

Measurement Parameter: Conductivity
Connector: Memosens
Explosion protection: Ex
Process Connection: G 1“ thread
Measuring Range: 0.001 … 500 µS/cm
Temperature Detector: NTC 30 kΩ
Measuring Principle: 2 electrodes
Pressure: Max. 10 bar (120 °C), Max. 25 bar (–20 … 70 °C)
Electrode Material: Stainless steel 1.4571
Ambient temperature: –25 … +80 °C
Cell constant: 0.029/cm
Signal Transmission: Memosens

Downloads

Manuals

[17405] User Manual
SE604X-MS
Ex Approval Japan (JPEx DEK19.0047X)
Version 05
[2737] User Manual
SE604(X) MS 2-Electrode Conductivity Sensor
Version 05
[16286] User Manual (DE, EN, KO)
Memosens Cable CA/MS
Version 09

Brochures

[13395] Brochure
Sensors - For measuring pH/ORP, conductivity or oxygen. Digital or analog.

Data Sheets

[2732] Data sheet
SE604(X) Memosens Conductivity Sensor
Product Description | Specifications | Product Range

Certificates

[14685] Certificate of Conformity (FM)
No. FM17US0208X | 2019-05-27 | USA
Memosens Sensors | Types SE 5**, SE 6** and SE 7**
[16292] Korean safety certificate Kosha (KO)
No. 2020-KA4BO-0368X
Measuring Cable CA/MS
[17547] Korean Safety Certificate
Ex ia IIC T3/T4/T6 Ga / 23-KA4BO-359X
SE604X-MS****
2023-07-25
[16646] Type Approval Certificate for Ex-Equipment
No. DEK19.0047X, Issue No. 0 (Japan)
SE604X-MS | SE605*-X*
[14690] Certificate of Conformity (FM)
No. FM17CA0105X | 2019-05-27 | Canada
Memosens Sensors | Types SE 5**, SE 6** and SE 7**
[12826] EU-Type Examination Certificate (DEKRA)
Nr. BVS 16 ATEX E 037 X | 2024-02-20
Memosens-Ex-Sensors

Control Drawings

[14185] Control Drawing
Inductive Sensor-Cable Connection System Memosens
Zeichnungsnummer 214.410-240

Our service

Used in Process or Applications

Measurement of pH values, dissolved oxygen, and conductivity in boiler feed water, steam, and condensate in combined gas turbines in power plants.
Measurement of pH values, dissolved oxygen, and conductivity as key parameters in the boiler feed water circuit.
Since steam generators fulfill application-critical functions and the cost of their downtime or replacement is extremely high, damage caused by wear should be prevented by monitoring water quality.
Reverse osmosis systems are used for water treatment in a wide range of industrial applications. The main application is industrial saltwater desalination.

Related Products