Skip to main content

SE706 Oxygen Sensor | Memosens | 220 mm | Ex | Measuring range (resolution) 0 ... 50 mg/l (6 μg/l)

Description

SE706 Oxygen Sensor | Memosens | 220 mm | Ex | Measuring range (resolution) 0 ... 50 mg/l (6 μg/l)

Sensor in robust and hygienic stainless steel design, high accuracy and low detection limit, simple and fast maintenance due to special membrane, digital, with Memosens technology.

  • perfect galvanic isolation thanks to Memosens technology
  • no influence of humidity in the connector
  • precalibration in the lab
  • digital data transfer
  • integrated sensor diagnostics
  • high level of process safety
  • durable materials
  • robust design
  • easy to clean thanks to extremely smooth surface
  • cost-efficient service due to easy-to-replace membrane module and interior body
  • hygienic design
  • high resolution of 6 ppb
  • operation also in hazardous locations

Reliable in-line measurement of dissolved oxygen, even under sterile and hygienic conditions. High signal stability. Simple maintenance due to modular design.

Special membrane with steel mesh and PTFE coating. Sterilizable, autoclavable and CIP capable. Also suitable for use in hazardous locations.

Applications
Biotechnology, pharmaceutical industry, fermentation, various fields of analytical chemistry

We look forward to hearing from you!
Contact Us

Technical details

Measurement Parameter: Oxygen
Permissible pressure range (measurement): 0.2 ... 6 bar absolute
Connector: Memosens
Explosion protection: Yes
Length: 220 mm
Measuring Range: pO₂ < 1200 mbar
Temperature Detector: NTC 22 kΩ
Measuring principle: Amperometric
Membrane material: PTFE / silicone / PTFE, FDA compliant (steel-mesh reinforced)
Flow dependence: ≤ 5 %
Signal Transmission: digital
Mechanical pressure resistance: Max. 12 bar absolute
Temperature range (stability): –5 ... +135 °C (steam sterilizable/autoclavable)
Accuracy: 1 % + 4 ppb
Signal in ambient air: 50 ... 110 nA
Response time at 25 °C (air –> N2): 98 % full scale < 90 s
Residual signal in O₂-free medium: ≤ 0.1 % of signal in ambient air
O-ring material (process-wetted): silicone (FDA & USP Class VI tested)
Process-wetted sensor parts: Stainless steel 1.4404 (material certificate 3.1B)
Surface roughness: N 5 (RA < 0.4 μm)
Interior body incl. electrodes: replaceable (ZU 0567)

Downloads

Manuals

[16286] User Manual (DE, EN, KO)
Memosens Cable CA/MS
Version 09
[17421] User Manual
SE706 Memosens
incl. Ex Approval Japan (JPEx DEK19.0046X)
Version 04
[3061] User Manual
SE706 Memosens Oxygen Sensor
Version 04

Brochures

[13395] Brochure
Sensors - For measuring pH/ORP, conductivity or oxygen. Digital or analog.

Data Sheets

[10145] Data sheet
Accessories for Sensors for Oxygen Measurement
Product Description | Specifications | Product Range
[3052] Data sheet
SE706 Memosens Oxygen Sensor
Product Description | Specifications | Product Range

Certificates

[11064] EU Declaration of Conformity
No. EU210427A | 2021-04-27
Memosens Sensors | Types SE 5..X..-.MS., SE604X-MS**, SE605….., SE6**X**MS, SE7**…
[12826] EU-Type Examination Certificate (DEKRA)
Nr. BVS 16 ATEX E 037 X | 2024-02-20
Memosens-Ex-Sensors
[12831] IECEx Certificate of Conformity
Memosens Ex Sensors | Details see Document
Document No. IECEx BVS 16.0030X, issue No. 2 | 2024-02-23
Marking: Ex ia IIC T3/T4/T6 Ga
[12902] Confirmation / Bestätigung
Series SE706X/*-NMSN, SE707X/*-NMSN
No components of animal origin / Kein tierischer Ursprung
[14155] Declaration of Compliance 2.1 (DE, EN)
according to EN 10204 | gemäß EN 10204
[14685] Certificate of Conformity (FM)
No. FM17US0208X | 2019-05-27 | USA
Memosens Sensors | Types SE 5**, SE 6** and SE 7**
[16292] Korean safety certificate Kosha (KO)
No. 2020-KA4BO-0368X
Measuring Cable CA/MS
[16639] Type Approval Certificate for Ex-Equipment (JA)
No. DEK19.0046X, Issue No. 0 (Japan)
SE5**X/*-*MSN | SE7**X/*-*MSN

Control Drawings

[14185] Control Drawing
Inductive Sensor-Cable Connection System Memosens
Zeichnungsnummer 214.410-240

Our service

Used in Process or Applications

The taste and quality of beer are highly dependent on the quality of the water used for brewing it. It is determined by pH and conductivity measurements.

Related Products

Relevant Blog Posts

SE605H conductivity sensor with CondCheck: Integrated sockets for connecting a resistance decade

SE605H Conductivity Sensor with CondCheck

The SE605H conductivity sensor with CondCheck enables USP 645 verification without interrupting the measuring chain.
Knick’s large, international team at its ACHEMA 2024 trade fair booth.

ACHEMA 2024 - Review and Impressions

A brief cinematic retrospective of our trade fair booth, Knick’s international team, and a successful booth party.

Uniclean 700 Series - Modular control system for automated sensor cleaning

With the Uniclean 700 series, Knick is introducing a modular control system, that can be installed very quickly and cost-effectively as a flexible entry-level solution for automated sensor cleaning.

Knick Austria - direct customer contact in Austria from 2024

Reorganization of sales in Austria and new contacts in the field of process analytics and interface technology

Robust WA111 Retractable Fitting Made of Plastic for Highly Corrosive Operating Conditions

The plastic WA111 retractable fitting is a robust and cost-effective solution for corrosive processes and environments. It is equipped with a secure lock function and multiple nozzles for thorough sensor cleaning.

Successful joint project : Knick developed the special Ceramat WA 155 retractable fitting for optical probes from SOPAT

In cooperation with SOPAT, Knick developed a special Ceramat fitting for optical probes for automatic cleaning in fouling processes.

pH and conductivity measurement in vaccine production

Pharmaceutical contract manufacturer relies on Knick's transmitters for modular production plants for Covid-19 vaccines.

Sturdy 2-Electrodes Conductivity Sensor SE625 with Coaxial Electrodes made of Titanium

The SE625 ensures reliable and accurate determination of the conductivity of ultrapure water in the semiconductor industry.

Sensor Adapter with Lock Function Enables Safe and Thorough Cleaning

Sensor adapter with locking gate for safety and thorough cleaning of sensors in the immersion fitting ARD75 without the need

Up to six Sensors on one Transmitter Protos II 4400 via Modul MSU4400-180

Users can now connect up to six Memosens sensors simultaneously.

ACHEMA 2022 - Knick at the world forum for the process industry

In August 2022, the international process industry met at the ACHEMA. Knick presented the cCare system and industrial applications in a new concept.

Combined pH- and ORP-Sensor SE555X/*-AMSN

Combined pH and ORP measurement in one sensor SE555 saves place and equipment costs for demanding requirements in the chemical industry, the food sector and for hygienic applications.

Ultra Compact Transmitter for Memosens Sensors

The new ultra compact MemoTrans MT201 transmitter plugs directly onto the Memosens sensor in the fitting and communicates via 4-20 mA HART protocol.

Conveniently configure transmitters offline on a PC - ProgaLog 4000

Conveniently configure all flexibly configurable Stratos Multi and Protos II 4400 transmitters offline, save settings, duplicate for further transmitters, and create documentation for audits.

New Stratos Multi E461N transmitter with Profinet

The interface enables continuous communication of process variables and predictive maintenance from the field level to all common process control systems.

Memosens 2.0: Evolution of digital data transfer

As one of the two initiators of Memosens, Knick is constantly developing the technology.

SE655X Digital and SE656X Digital - Digital Conductivity Sensors with Ex Certification

The SE655X digital and SE656X digital conductivity sensors with Memosens protocol are now also available with Ex certification.

ILMAC 2021 in Basel - Trade Show Review by Knick Schweiz AG

Knick Schweiz AG exhibited at ILMAC in Basel and gives a brief review of what it's like to have finally met customers at the show again.

Stratos Multi E401X- Multiparameter Transmitter for Hazardous Locations

The new Multiparameter Transmitter Stratos Multi E401X can now also be used in hazardous locations, installed in Ex Zone 2.

Stratos Multi E471 with EtherNet/IP for process optimization

EtherNet/IP communication protocol allows the transmitter to be easily integrated into Industrial Ethernet networks as PCS.

New SE656N digital conductivity sensor

New toroidal Digital Conductivity Sensor with a large measuring range and consisting of PFA for using in aggressive media

Transmitter for the process industry with PROFINET module

The PROFINET industrial Ethernet standard is becoming an increasingly important aspect of process engineering in the “Industry 4.0” environment.

High-quality immersion fitting for mobile applications

ARD 170 enables measurements even in deep water

Modular immersion fitting as an electrically conductive variant

Knick is expanding its portfolio of fittings for liquid analysis with additional electrically conductive (EL) variants.

New multiparameter transmitter Stratos Multi

Knick is launching the the next generation in its Stratos analyzer product line.

How to get the sensor into the process

Sensors as the direct interface to the process must be exactly matched to the chemistry of the measured medium and to the prevailing pressure and temperature conditions.

Powerful compact analyzer boosts performance while reducing costs

It has long been common practice when taking pH/ORP, conductivity, and oxygen measurements that a fixed analyzer be mounted near the sensor. The analyzer serves several purposes.

High-Precision Conductivity Measurement at Extreme Temperature Differences

Pharmaceutical manufacturer, EVER Pharma Jena uses the extremely robust conductivity sensors SE605(H) and SE680 with Memosens technology from Knick.

The Big Three of the Process Industry: HART, FF, Profibus

Our Knick multi-parameter analyzers are now available with Profibus and FF interfaces. Even for hazardous areas.