Skip to main content

Portavo 907 Multichannel MS Portable Multiparameter Transmitter | Memosens Sensors | Multichannel Function | Data Logger | Add-On Functions

Description

Portavo 907 Multichannel MS Portable Multiparameter Transmitter | Memosens Sensors | Multichannel Function | Data Logger | Add-On Functions

Portable multiparameter analyzer with multi-channel function for simultaneous measurement with Memosens sensors

  • Multiparameter:
    • pH
    • ORP
    • Contacting conductivity
    • Toroidal conductivity
    • Amperometric oxygen
    • Optical oxygen
    • Temperature
  • Oxygen measurement in liquids or in the gaseous phase
  • Multichannel function
  • GLP compliant
  • User management
  • New add-on functions, such as a new pH calibration procedure, user management, sensor verification, and calibration of the temperature detector, are available as options.
  • Digital Memosens sensors
  • Concentration measurement with toroidal conductivity sensors
  • Sturdy, practical, convenient
  • Li-ion rechargeable battery - USB chargeable

Portavo 907 Multichannel MS is the first multi-channel device in the Portavo product line. Any 2 Memosens sensors can be connected at the same time. In addition to a Memosens sensor, it is also possible to use the SE 340 digital optical oxygen sensor.

Many new features distinguish the Portavo 907 Multichannel MS for use in the pharmaceutical and biotech field. These include 

  • a new pH calibration procedure with a fixed process cycle
  • multi-level user management with access control
  • direct assignment of Memosens sensors to the device,which increases safety in operation.

Custom pH Calibration
Cal SOP

The new Cal SOP calibration procedure allows pH sensors to be checked with up to 3 calibration points. A further buffer is used as the verification buffer. The buffer set for each calibration point can be separately selected, thus also allowing their order to be determined.

Custom buffer solutions can be used, or choose from a list of commercially available buffer sets, e.g., CaliMat, NIST, and DIN. A maximum permissible deviation (Delta pH) is entered for the verification buffer.

Full Measured Value Recording
Data logger functionality for both sensors in use. Measurement data is saved and displayed directly in the device.

Security Package Included
User management

The Portavo 907 Multichannel MS’s professional user management regulates access to the device and the sensor.

  • Increased security for configuration, calibration, and measurement data
  • No unauthorized interventions during the operating cycle
  • Up to 4 user profiles can be set
  • Different access rights can be established

Depending on the user’s experience, the role profile can optionally be defined for configuration of the device and sensor or for sensor calibration. This clearly minimizes the risk of inadvertently changing settings.

Greater Reliability During Operation
Memosens sensors can be assigned directly to Portavo 907 Multichannel MS using the data stored in the sensor, such as

  • Sensor type
  • TAG
  • Group

Unambiguous assignment of the sensor to the device reduces the potential for errors. This ensures that only the right sensors are used for the selected measuring point.

We look forward to hearing from you!
Contact Us

Technical details

Additional functions: Sensor verification, Temperature Adjustment, User management
Channels: 2 channels
Data Logger: data logger with 10,000 entries
Display: QVGA TFT display with white backlighting
Measurement Parameter: Multiparameter
Sensor Connection: Memosens
permanently installed / portable: portable
Explosion protection: non Ex
Enclosure: PA12 GF30 + TPE

Downloads

Manuals

[14442] Quickstart Guide
Portavo 907 Multi
Version 04
[13862] Safety Guide
Portavo 900 Series
Version 04
[1968] User Manual
Portavo 907 Multi
Version 05
[16861] ChangeLog Firmware History
Portavo-907-908
[12673] User Manual
Software Paraly SW 112
Version 05

Brochures

[16192] Brochure
Portavo (Overview)

Data Sheets

Data sheet
Portavo 907 Multichannel MS
Product Description | Specifications | Product Range
[2022] Datasheet
Overview of Portavo

Certificates

[11539] EU Declaration of Conformity (DE, EN, FR)
Serie / Series / Série Portavo 900
No. EU211124A | 2021-11-24

Software

[12703] Software
Paraly SW 112 PC Software
[18054] Software
KnUT (Knick Update Tool)

Our service

Used in Process or Applications

Knick offers innovative process analyzers, high quality holders and fittings, and unique cleaning and calibration systems

Related Products

Relevant Blog Posts

Stack and String Voltage Measurement in Electrolyzers and Fuel Cells

Voltage, current and temperature measurement in electrolyzers with P40000 series high voltage transducers

New 30 mV Shunt Resistors for Knick Transducers

Knick is expanding the accessory range for its high-voltage transducers with immediate effect by adding shunt resistors with a 30 mV voltage drop
Innovations at InnoTrans 2024

Innovations at InnoTrans 2024 for rolling stock and DC traction power supply

At InnoTrans 2024 Knick presents electrical measurement solutions for rolling stock and DC traction power supply applications

Knick Austria - direct customer contact in Austria from 2024

Reorganization of sales in Austria and new contacts in the field of process analytics and interface technology

Energy storage - the handshake between renewable energy and electric vehicles

Energy storage technology such as battery and hydrogen are critical for growth and continuous development of renewable energy and e-mobility.

P52000VPD voltage presence detector reliably detects voltages up to 4200 V DC

The new P52000VPD voltage presence detector reliably monitors areas with high voltages and sends a signal to the downstream plant control system when a specified threshold value is reached.

Knick Interface at Battery and Electric & Hybrid Vehicle Technology Expo

Knick will be showcasing high-voltage electrical measurement and signal conversion products.

Quadruple Standard Signals in Just One Signal Conditioner

The A20340 can output a standard input signal to four calibrated and galvanically isolated outputs in parallel.

Electrical measurement and process analytics for hydrogen production

Knick products optimize hydrogen production in the process and in electrolyser operation.

Condition Monitoring of High-Voltage Motors

Having an active predictive maintenance campaign in place for large rotating equipment can be a key strategy for maximizing process uptime.

Pulse frequency conditioner for speed sensors

The new P16000 from Knick is a pulse frequency conditioner that converts frequency signals from speed sensors into standard signals.

Worldwide smallest transducer up to ±2200 V

The P40000 series from Knick enables reliable voltage measurements from ±50 mV to ±3600 V and current measurements from ±100 mA to ±20 kA.

Importance of broad-range power supplies for DC electrical measurement

Many DC electrical measurement products manufactured by Knick contain universal, also known as broad-range, power supplies.

Measuring Photovoltaic Degradation

Photovoltaic (PV) array degradation is an important aspect to consider for system design and installation.

Electrical Measurement Solutions: Control from 480 to 4800 Volts

Voltage and current transducers from Knick bring true control to electrical measurement applications across a wide-range of industries.

Benefits of High Voltage Transducers versus Instrument Transformers

When a need arises to step voltage in a circuit either up or down for purposes of power transmission or distribution, there is no doubt that transformers are essential.

Shunt Resistor versus Hall Effect Technology

There are many systems where measurement of large DC currents are needed for performance and safety.

MTBF beyond 3000 years: A snap hook for your plant

Failure of equipment on the plant floor can lead to considerable and costly disruption.

Knick Products Comply With UL - What Does That Mean?

There are different assessments and approaches to reach an adequate level of safety. Manufacturers are typically on the “safe” side, if they comply with recognized standards.

High-voltage transducer offers more safety on railway vehicles

The requirements placed on railway vehicles have increased significantly in recent years. Products for rolling stock need to ensure a higher level of functional safety than ever before.

True RMS Measurement with P41000TRMS

Traditional millivolt AC transducers are very susceptible to errors due to their poor insulation and are only designed for pure sinewave measurement.

Functional safety and maximum availability can go together

The requirements on operational and safety-related circuits are continuously growing.