Skip to main content

Protos II 4400 C Modular Multiparameter-Transmitter | Wide Sensor Selection | Corrosion-Proof Coating | 4-Wire | Broad-Range Power Supply

Description

Protos II 4400 C Modular Multiparameter-Transmitter | Wide Sensor Selection | Corrosion-Proof Coating | 4-Wire | Broad-Range Power Supply

The Protos II 4400 (X) premium transmitter is a flexible, 4-wire device for the following process variables: pH, ORP, conductivity and oxygen. 

For monitoring and controlling processes even in the most complex applications.

  • Stainless steel design with corrosion-proof powder coating for harsh industrial areas
  • Universal broad-range power supply 24 ... 230 V AC/DC
  • Rugged; can also be used outdoors with IP 65 protection and UV resistance
  • Panel, wall or post/pipe mounting
  • Multiparameter and multichannel function with up to 6 Memosens sensors
  • High-contrast graphic LC display
  • USB memory card concept for data recording, firmware updates, and Audit Trail
  • Freely combinable measuring, control, and communication modules
  • 4-wire system with active current outputs (standard in BASE module)
  • High-resolution graphic display
  • Parameter set changeover for greater process control flexibility
  • KI recorder for signaling faulty processes
  • Softkeys for flexible, intuitive operation
  • Flexible combination of sensors and process variables

Retrofits Possible, Future-Proof
Protos II 4400 (X) features a unique modular design and freely accessible wiring with a clear layout. The option for easy retrofitting and upgrading ensure planning security today and in the future. Different Ethernet and Fieldbus modules enable digital communication and seamless integration into automation systems.

Wide Sensor Selection
Protos II 4400 (X) is the only process analysis system that can be  flexibly combined with Memosens and other digital or analog sensors —  in multi-channel mode as well. 
With Memosens technology, up to 6 measuring channels can be imple-mented in parallel.

Status Messages acc. to NE 107
All status messages for maintenance requests, failure, out of specification, and function check (HOLD) are output as specified in NE 107.

Reliable and Safe Thanks to  Memosens Technology
Digital sensors with inductive signal transmission — contactless sensor couplings ensure the reliable analysis of liquid in all environments. Sensors that are pre-calibrated in the laboratory deliver maximum availability and reduced maintenance efforts at the point of measurement. Even for non-specialist employees, sensors can be replaced on site in just a matter of seconds.

 

We look forward to hearing from you!
Contact Us

Technical details

2- or 4-wire: 4 Wire
Communication (Output, Digital): Foundation Fieldbus, PROFIBUS, PROFINET
Display: High-contrast graphic LC display
Measurement Parameter: Conductivity (inductive), pH, Multiparameter, Oxygen, ORP , Conductivity
Memory Card: Data Card, FW Update Card, Firmware Repair Card
Explosion protection: non Ex
Enclosure: Stainless steel, coated
Product Line: Protos

Downloads

Manuals

[14635] User Manual
Protos II 4400(X) - TAN Options
Device-specific add-on functions for expanding functionality
[14601] User Manual
Protos II 4400(X) Process Analysis System
FRONT and BASE Modules
Version 02
[16957] User Manual
ProgaLog 4000
PC configuration tool for transmitters
[16352] ChangeLog Firmware History
Protos II 4400 | ChangeLog Firmware History
Document version 1.0
[17320] User Manual
Unical 9000/Protos II 4400
Version 02
[18024] ChangeLog
ProgaLog 4000

Brochures

[14505] Brochure
Protos II 4400 (X) - Ready for the Future

Data Sheets

[14500] Data sheet
Protos II 4400 (X)
Product Description | Specifications | Product Range

Certificates

[14665] EU Declaration of Conformity (DE, EN, FR)
Protos 3400 */*** & Protos II Type 4400*/***
Device and Modules
No. EU220510A | 2022-05-10
[16322] Quality Test Certificate
Protos II 4400C
Test for the certification of the corrosive resistance
No. 20-15685 Rev.01
[14660] EU Declaration of Conformity (DE, EN, FR)
No. EU210301C | 2021-03-01
Protos Front 4400*
[18020] IECEx Certificate of Conformity
Types Unical 9000-X… and Uniclean 900-X…
No.: IECEx DEK 22.0022 | 2022-07-28
Issue No. 0

Installation guides

[16963] Installation Guide / Installationsanleitung
ProgaLog 4000 | PC configuration tool for transmitters / ProgaLog 4000 | PC-Parametriertool für Transmitter
Version 01
[14541] Installation Guide
Protos II 4400(X) FRONT and BASE Modules
Module FRONT und BASE
Version 04
[14618] Installation Guide
Protos II 4400(X) - Replacement of FRONT Module
Version 01

Safety guides

[14624] Safety Guide
Protos II 4400(X)

Software

[16419] GSD
COMPA 3400(X)-081
[18016] Software
Progalog Configuration Tool
[18035] GSD
PN4400-095
[13831] EDD (PDM)
COMPA 3400(X)-081
Firmware Version ≧ COMPA 2.4.00
Device Revision 301.7
[16425] EDD (PDM)
COMPA 3400(X)-081
Firmware Version ≧ ≥ COMPA 2.4.00
Device Revision 301.6
[17196] FDI
COMPA 3400(X)-081
Firmware Version ≧ COMPA 2.4.00
Device Revision 301.1
[13836] DTM (Pactware)
COMPA 3400(X)-081
Firmware Version ≧ COMPA 2.4.00
Device Revision 301.7
[16437] DTM (Pactware)
COMPA 3400(X)-081
Firmware Version ≧ COMPA 2.2.00
Device Revision 301.6
[18054] Software
KnUT (Knick Update Tool)

Our service

Used in Process/Application New

pH value measurement in the pre-scrubber, the neutralization phase, and the lime scrubber as part of the flue gas desulfurization process in power plants.
Toxic sludge that must be treated for phosphorus recovery is produced in biological wastewater treatment plants.

You need also


Protos Module

Relevant Blog Posts