Skip to main content

Stratos Pro A201 COND Conductivity Transmitter | Analog Sensors | Ex Zone 0/1 | HART | 2x 4 ... 20 mA Outputs

Description

Stratos Pro A201 COND Conductivity Transmitter | Analog Sensors | Ex Zone 0/1 | HART | 2x 4 ... 20 mA Outputs

2-wire analyzer for conductivity measurement

  • Explosion protection: Zone 1 / Class 1 Division 1 (with sensor in Zone)
  • Digital communication: HART 
  • Two current outputs
  • Intuitive operation with color-coded user guidance
  • IP 66/67, NEMA 4X protection
  • Automatic sensor identification
  • Sensor diagnostic with wear indication, remaining lifetime, CIP/SIP counter and adaptive calibration timer
  • High-contrast widescreen display with colored backlighting
  • Protective pane made of safety glass
  • One analog input (4 ... 20 mA) e.g. for external pressure compensation
  • Two parameter sets
  • Two digital inputs: 
    • External HOLD activation
    • External switching between parameter set
  • Logbook (200 entries)
Outstanding properties
A number of outstanding technological properties make the Stratos Pro series the new benchmark for 2-wire analyzers. Colored screen backlighting has been implemented for the first time in this device class, with the lowest possible power consumption.
 
Wide Range of Functions
2 digital inputs are provided, as well as an analog input plus a second current output for another measured value. 
 
Zone 1 Explosion Protection
Stratos Pro is designed for operation in Zone 1 / Class 1 Division 1 hazardous areas (with the sensor in Zone 0). Operation in hazardous areas from –20 °C to +65 °C is possible. The devices are designed for gas and dust explosion protection (G/D) and can naturally also be used outdoors (type 4 enclosure, UV resistant).

We look forward to hearing from you!
Contact Us

Technical details

2- or 4-wire: 2 Wire
Channels: 1 channel
Communication (Output, Digital): HART
Display: LC display with colored backlighting
Measurement Parameter: Conductivity
Sensor Connection: Analog
permanently installed / portable: permanently installed
Current outputs: 2x 4 … 20 mA
Explosion protection: Ex, hazardous area Zone 1
Enclosure: Molded enclosure, PBT/PC, glass-reinforced
Product Line: Stratos, Stratos Pro

Downloads

Manuals

[13527] Transmitter Specific HART Command Specification
Stratos Pro A201 Cond / A401 Cond
Device Revision: 2
[13532] Transmitter Specific HART Command Specification
Stratos Evo A402 Cond / Stratos Pro A201 Cond
Device Revision: 5 (A402) & 3 (A201 Cond)
[17264] Transmitter Specific HART Command Specification
Stratos Pro A201 Cond
Device Revision: 4
[3945] User Manual
Stratos Pro A201 COND
Conductivity Measurement with 2-/4-Electrode Sensors
Version 05
[18110] Transmitter Specific HART Command Specification
Stratos Pro A201 (MS) Cond | Device Revision: 5
Stratos Evo A402 Cond | Device Revision: 6
[13326] ChangeLog Firmware History
Stratos Pro A201 COND
11/18/2024

Brochures

[14695] Brochure
Stratos Pro
2-wire analyzers for pH/ORP, conductivity or oxygen

Data Sheets

[16180] Data sheet (EN)
Stratos Pro A201
Product Description | Specifications | Product Range

Certificates

[16316] Certitficate of Conformity (China - Ex NEPSI)
Cert No. GYJ20.1052X | 2020-06-10
Stratos Pro A20..X / Multi E401X
[17027] EU Type-Examination Certificate
No. KEMA 08ATEX0100 | 2024-03-07
Issue No. 10
Stratos Pro Types A201X…, A201X-*-0-T6, A211X…, A221X… and A231X… | Stratos Multi Type E401X
[17021] IECEx Certificate of Conformity
No. IECEX KEM 08.0020
Issue No. 9 | 2024-03-07
Stratos Pro Types A201X…, A201X-*-0-T6, A211X…, A201B…, A221X…, A231X | Stratos Multi Type E401X
[8040] Certificate of Conformity (FM-Canada)
No. FM21CA0052 (Canada) | 2021-11-01
Stratos Pro Types A201X…, A211X…, A201B…, A221X… and A231X… | Stratos Multi Type E401X
[12932] EU Declaration of Conformity
No. EU210721B | 2021-07-21
for Stratos Pro Type A201X…
[16250] Korean safety certificate
No. 2020-KA4BO-0349
Stratos Pro A201X
[8682] Certificate of Compliance (FM)
No. FM21US0078 | 2023-11-02
Stratos Multi E401X…, Stratos Pro A201X…, A211X…, A201B…, A221X…, A231X
[12917] Quality Control Certificate
Device Settings for Customer-Specific Buffer Solutions
Version 01

Safety guides

[7598] Safety Guide
Stratos Pro / MS / Evo Series
Installation and Use in Hazardous Locations
Version 05

Control Drawings

[13028] Control Drawing
Stratos Pro Type A20.X... or A21.X... | A20.B... or A21.B...
Zeichnungsnummer 212.110-066 page 2 rev.0
cFMus
[13038] Control Drawing
Stratos Pro Type A20.X…
Zeichnungsnummer 212.002-100 page 3 rev.7
INMETRO
[13043] Control Drawing
Stratos Pro Type A201X-*-0-T6
Zeichnungsnummer 212.002-100 page 5 rev.4
ATEX, IECEx

Software

[17252) EDD (PDM)
Stratos Pro A201 Cond
Device Revision 04
[13517] EDD (PDM)
Stratos Pro A201 Cond
Device Revision 03
[12216] EDD (PDM)
Stratos Pro A201 Cond
Device Revision 02
[13512] DTM (Pactware)
Stratos Pro A201 Cond
Device Revision 03
[12220] DTM (Pactware)
Stratos Pro A201 Cond
Device Revision 02
[18094] EDD (PDM)
Stratos Pro A201 (MS) Cond
Device Revision 05
[18086] EDD (AMS)
Stratos Pro A201 (MS) Cond
Device Revision 05
[18102] DTM (Pactware)
Stratos Pro A201 (MS) Cond
Device Revision 05
[17246] EDD (AMS)
Stratos Pro A201 (MS) Cond
Device Revision 04
[13522] EDD (AMS)
Stratos Pro A201 (MS) Cond
Device Revision 03
[12228] EDD (AMS)
Stratos Pro A201 Cond
Device Revision 02
[18054] Software
KnUT (Knick Update Tool)

Our service

Used in Process or Applications

In a wide range of industrial sectors, cooling towers are used to dissipate process heat from cooling circuits. Mineral deposits and corrosion reduce their efficiency and lead to premature wear on plant parts.

Related Products

Relevant Blog Posts