Skip to main content

Stratos Pro A201 COND Conductivity Transmitter | Analog Sensors | HART | 4 ... 20 mA Output

Description

Stratos Pro A201 COND Conductivity Transmitter | Analog Sensors | HART | 4 ... 20 mA Output

2-wire analyzer for conductivity measurement

  • Digital communication: HART 
  • Intuitive operation with color-coded user guidance
  • IP 66/67, NEMA 4X protection
  • Automatic sensor identification
  • Sensor diagnostic with wear indication, remaining lifetime, CIP/SIP counter and adaptive calibration timer
  • High-contrast widescreen display with colored backlighting
  • Protective pane made of safety glass
  • One analog input (4 ... 20 mA) e.g. for external pressure compensation
  • Two parameter sets
  • Two digital inputs: 
    • External HOLD activation
    • External switching between parameter set
  • Logbook (200 entries)
Outstanding properties
A number of outstanding technological properties make the Stratos Pro series the new benchmark for 2-wire analyzers. Colored screen backlighting has been implemented for the first time in this device class, with the lowest possible power consumption.
 
Wide Range of Functions
2 digital inputs are provided, as well as an analog input plus a second current output for another measured value. 

We look forward to hearing from you!
Contact Us

Technical details

2- or 4-wire: 2 Wire
Channels: 1 channel
Communication (Output, Digital): HART
Display: LC display with colored backlighting
Measurement Parameter: Conductivity
Sensor Connection: Analog
permanently installed / portable: permanently installed
Current outputs: 1x 4 … 20 mA
Explosion protection: non Ex
Enclosure: Molded enclosure, PBT/PC, glass-reinforced
Product Line: Stratos, Stratos Pro

Downloads

Manuals

[13532] Transmitter Specific HART Command Specification
Stratos Evo A402 Cond / Stratos Pro A201 Cond
Device Revision: 5 (A402) & 3 (A201 Cond)
[13527] Transmitter Specific HART Command Specification
Stratos Pro A201 Cond / A401 Cond
Device Revision: 2
[17264] Transmitter Specific HART Command Specification
Stratos Pro A201 Cond
Device Revision: 4
[3945] User Manual
Stratos Pro A201 COND
Conductivity Measurement with 2-/4-Electrode Sensors
Version 05
[18110] Transmitter Specific HART Command Specification
Stratos Pro A201 (MS) Cond | Device Revision: 5
Stratos Evo A402 Cond | Device Revision: 6
[13326] ChangeLog Firmware History
Stratos Pro A201 COND
11/18/2024

Brochures

[14695] Brochure
Stratos Pro
2-wire analyzers for pH/ORP, conductivity or oxygen

Data Sheets

[16180] Data sheet (EN)
Stratos Pro A201
Product Description | Specifications | Product Range

Certificates

[12917] Quality Control Certificate
Device Settings for Customer-Specific Buffer Solutions
Version 01

Safety guides

[7598] Safety Guide
Stratos Pro / MS / Evo Series
Installation and Use in Hazardous Locations
Version 05

Software

[13517] EDD (PDM)
Stratos Pro A201 Cond
Device Revision 03
[17252) EDD (PDM)
Stratos Pro A201 Cond
Device Revision 04
[12216] EDD (PDM)
Stratos Pro A201 Cond
Device Revision 02
[17258] DTM (Pactware)
Stratos Pro A201 Cond
Device Revision 04
[12220] DTM (Pactware)
Stratos Pro A201 Cond
Device Revision 02
[13512] DTM (Pactware)
Stratos Pro A201 Cond
Device Revision 03
[18094] EDD (PDM)
Stratos Pro A201 (MS) Cond
Device Revision 05
[18086] EDD (AMS)
Stratos Pro A201 (MS) Cond
Device Revision 05
[18102] DTM (Pactware)
Stratos Pro A201 (MS) Cond
Device Revision 05
[17246] EDD (AMS)
Stratos Pro A201 (MS) Cond
Device Revision 04
[13522] EDD (AMS)
Stratos Pro A201 (MS) Cond
Device Revision 03
[12228] EDD (AMS)
Stratos Pro A201 Cond
Device Revision 02
[18054] Software
KnUT (Knick Update Tool)

Our service

Used in Process or Applications

In a wide range of industrial sectors, cooling towers are used to dissipate process heat from cooling circuits. Mineral deposits and corrosion reduce their efficiency and lead to premature wear on plant parts.

Related Products

Relevant Blog Posts