Skip to main content

Stratos Pro A201 MSCONDI Inductive Conductivity Transmitter | Memosens Sensors | Ex Zone 2 | HART | 4 ... 20 mA Output

Description

Stratos Pro A201 MSCONDI Inductive Conductivity Transmitter | Memosens Sensors | Ex Zone 2 | HART | 4 ... 20 mA Output

2-wire analyzer for conductivity measurement

  • Extensive diagnostic functions with Memosens sensors
  • Operation in hazardous areas
  • Digital communication: HART 
  • Intuitive operation with color-coded user guidance
  • IP 66/67, NEMA 4X protection
  • Automatic sensor identification
  • Sensor diagnostic with wear indication, remaining lifetime, CIP/SIP counter and adaptive calibration timer
  • High-contrast widescreen display with colored backlighting
  • Protective pane made of safety glass
  • One analog input (4 ... 20 mA) e.g. for external pressure compensation
  • Two parameter sets
  • Two digital inputs: 
    • External HOLD activation
    • External switching between parameter set
  • Logbook (200 entries)
Outstanding properties
A number of outstanding technological properties make the Stratos Pro series the new benchmark for 2-wire analyzers. Colored screen backlighting has been implemented for the first time in this device class, with the lowest possible power consumption.
 
Wide Range of Functions
2 digital inputs are provided, as well as an analog input plus a second current output for another measured value. 

We look forward to hearing from you!
Contact Us

Technical details

2- or 4-wire: 2-wire
Channels: 1 channel
Communication (Output, Digital): HART
Display: LC display with colored backlighting
Measurement Parameter: Conductivity (inductive)
Sensor Connection: Memosens
permanently installed / portable: permanently installed
Current outputs: 1x 4…20 mA
Explosion protection: hazardous area Zone 2
Enclosure: Molded enclosure, PBT/PC, glass-reinforced
Product Line: Stratos, Stratos Pro

Downloads

Manuals

[13752] Transmitter Specific HART Command Specification
Stratos Pro A201 CondI
Device Revision 03
[17288] Transmitter Specific HART Command Specification
Stratos Pro A201 CondI
Device Revision 04
[3939] User Manual
Stratos Pro A201MSCONDI
Conductivity Measurement with Toroidal Sensors via Memosens Protocol
Version 04

Brochures

[13209] Brochure
Memosens - The complete solution for smart sensor applications.
[14695] Brochure
Stratos Pro
2-wire analyzers for pH/ORP, conductivity or oxygen

Data Sheets

[16180] Data sheet (EN)
Stratos Pro A201
Product Description | Specifications | Product Range

Certificates

[12917] Quality Control Certificate
Device Settings for Customer-Specific Buffer Solutions
Version 01
[12942] EU Declaration of Conformity (DE, EN, FR)
No. EU220113A | 2022-01-13
for Stratos Pro Type A201B…
[17021] IECEx Certificate of Conformity
No. IECEX KEM 08.0020
Issue No. 9 | 2024-03-07
Stratos Pro Types A201X…, A201X-*-0-T6, A211X…, A201B…, A221X…, A231X | Stratos Multi Type E401X
[17027] EU Type-Examination Certificate
No. KEMA 08ATEX0100 | 2024-03-07
Issue No. 10
Stratos Pro Types A201X…, A201X-*-0-T6, A211X…, A221X… and A231X… | Stratos Multi Type E401X
[8040] Certificate of Conformity (FM-Canada)
No. FM21CA0052 (Canada) | 2021-11-01
Stratos Pro Types A201X…, A211X…, A201B…, A221X… and A231X… | Stratos Multi Type E401X
[8682] Certificate of Compliance (FM)
No. FM21US0078 | 2023-11-02
Stratos Multi E401X…, Stratos Pro A201X…, A211X…, A201B…, A221X…, A231X
[9523] Certitficate of Conformity (China - Ex NEPSI)
Cert No. GYJ20.1053X | 2020-06-10
Stratos Pro A2..B

Safety guides

[7598] Safety Guide
Stratos Pro / MS / Evo Series
Installation and Use in Hazardous Locations
Version 05

Control Drawings

[13023] Control Drawing
Stratos Pro Types A201X..., A211X..., A201B...
Zeichnungsnummer 212.002-100 page 1 rev.8
ATEX, IECEx
[13028] Control Drawing
Stratos Pro Type A20.X... or A21.X... | A20.B... or A21.B...
Zeichnungsnummer 212.110-066 page 2 rev.0
cFMus

Software

[13537] DTM (Pactware)
Stratos Pro A201 CondI
Device Revision 03
[13542] EDD (PDM)
Stratos Pro A201 CondI
Device Revision 03
[13550] EDD (AMS)
Stratos Pro A201 CondI
Device Revision 03
[17276] EDD (PDM)
Stratos Pro A201 CondI
Device Revision 04
[18054] Software
KnUT (Knick Update Tool)

Our service

Used in Process or Applications

slide 1 of 1