Product added to compare
Product Compare added Product Compare

Stratos Pro A201 PH pH/ORP Transmitter | Analog Sensors | Ex Zone 2 | HART | 4 ... 20 mA Output

Description

Stratos Pro A201 PH pH/ORP Transmitter | Analog Sensors | Ex Zone 2 | HART | 4 ... 20 mA Output

2-wire-transmitter for pH and ORP measurement

  • Operation in hazardous areas
  • Digital communication: HART
  • Intuitive operation with color-coded user guidance
  • IP 66/67, NEMA 4X protection
  • Automatic sensor identification
  • Sensor diagnostic with wear indication, remaining lifetime, CIP/SIP counter and adaptive calibration timer
  • High-contrast widescreen display with colored backlighting
  • Protective pane made of safety glass
  • One analog input (4 ... 20 mA) e.g. for external pressure compensation
  • Two parameter sets
  • Two digital inputs: 
    • External HOLD activation
    • External switching between parameter set
  • Logbook (200 entries)
Outstanding properties
A number of outstanding technological properties make the Stratos Pro series the new benchmark for 2-wire analyzers. Colored screen backlighting has been implemented for the first time in this device class, with the lowest possible power consumption.
 
Wide Range of Functions
2 digital inputs are provided, as well as an analog input plus a second current output for another measured value. 

We look forward to hearing from you!
Contact Us

Technical details

2- or 4-wire: 2 Wire
Channels: 1 channel
Communication (Output, Digital): HART
Current ouput: 1x 4 … 20 mA
Display: LC display with colored backlighting
Measurement Parameter: pH/ORP
Sensor Connection: Analog
permanently installed / portable: permanently installed
Explosion protection: Ex, hazardous area Zone 2
Enclosure: Molded enclosure, PBT/PC, glass-reinforced
Product Line: Stratos, Stratos Pro

Downloads

Manuals

[3940] User Manual
Stratos Pro A201 PH
pH Measurement
Version 05
[9136] Quickstart Guide
Stratos Pro A2... PH
pH Measurement
Version 03
[16503] Transmitter Specific HART Command Specification
Stratos Pro A201 pH / Stratos Evo A402 pH
Device Revision: 08
[14536] Transmitter Specific HART Command Specification
Stratos Pro A201 PH
Device Revision: 7
[13887] Transmitter Specific HART Command Specification
Stratos Pro A201 PH
Device Revision: 6
[13662] Transmitter Specific HART Command Specification
Stratos Evo A402 pH / Stratos Pro A201 pH
Device Revision: 5
[13502] Transmitter Specific HART Command Specification
A211 PH / A411 PH
Device Revision: 3
[13497] Transmitter Specific HART Command Specification
A211 PH / A411 PH
Device Revision: 2

Brochures

[14695] Brochure
Stratos Pro
2-wire analyzers for pH/ORP, conductivity or oxygen

Data Sheets

[16180] Data sheet (EN)
Stratos Pro A201
Product Description | Specifications | Product Range

Certificates

[8040] Certificate of Conformity (FM-Canada)
No. FM21CA0052 (Canada) | 2021-11-01
Stratos Pro Types A201X…, A211X…, A201B…, A221X… and A231X… | Stratos Multi Type E401X
[12942] EU Declaration of Conformity (DE, EN, FR)
No. EU220113A | 2022-01-13
for Stratos Pro Type A201B…
[17021] IECEx Certificate of Conformity
No. IECEX KEM 08.0020
Issue No. 9 | 2024-03-07
Stratos Pro Types A201X…, A201X-*-0-T6, A211X…, A201B…, A221X…, A231X | Stratos Multi Type E401X
[17027] EU Type-Examination Certificate
No. KEMA 08ATEX0100 | 2024-03-07
Issue No. 10
Stratos Pro Types A201X…, A201X-*-0-T6, A211X…, A221X… and A231X… | Stratos Multi Type E401X
[9523] Certitficate of Conformity (China - Ex NEPSI)
Cert No. GYJ20.1053X | 2020-06-10
Stratos Pro A2..B
[12917] Quality Control Certificate
Device Settings for Customer-Specific Buffer Solutions
Version 01

Safety guides

[7598] Safety Guide
Stratos Pro / MS / Evo Series
Installation and Use in Hazardous Locations
Version 05

Software

[16497] DTM (Pactware)
Stratos Pro A201 pH
Device Revision 08
[14526] DTM (Pactware)
Stratos Pro A201 pH
Device Revision 07
[13872] DTM (Pactware)
Stratos Pro A201 pH
Device Revision 06
[13468] DTM (Pactware)
Stratos Pro A201 pH
Device Revision 04
[12212] DTM (Pactware)
Stratos Pro A201 pH
Device Revision 03
[16491] EDD (PDM)
Stratos Pro A201 pH
Device Revision 08
[14531] EDD (PDM)
Stratos Pro A201 pH
Device Revision 07
[13877] EDD (PDM)
Stratos Pro A201 pH
Device Revision 06
[13482] EDD (PDM)
Stratos Pro A201 pH
Device Revision 04
[13477] EDD (PDM)
Stratos Pro A201 pH
Device Revision 03
[12198] EDD (PDM)
Stratos Pro A201 pH
Device Revision 02
[16485] EDD (AMS)
Stratos Pro A201 pH
Device Revision 08
[14521] EDD (AMS)
Stratos Pro A201 pH
Device Revision 07
[13882 EDD (AMS)
Stratos Pro A201 pH
Device Revision 06
[13460] DTM (Pactware)
Stratos Pro A201 pH
Device Revision 02
[13492) EDD (AMS)
Stratos Pro A201 pH
Device Revision 04
[13487) EDD (AMS)
Stratos Pro A201 pH
Device Revision 03
[12200) EDD (AMS)
Stratos Pro A201 pH
Device Revision 02

Our service

Lorem lorem ipsum ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet. Lorem ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet.

Used in Process or Applications

Cooling towers are used in a range of industrial sectors for diverting process heat from cooling circuits. Mineral deposits and corrosion reduce efficiency and lead to the premature wear of system components…

Related Products

Relevant Blog Posts

pH and conductivity measurement in vaccine production

Pharmaceutical contract manufacturer relies on Knick's transmitters for modular production plants for Covid-19 vaccines.

New Stratos Multi E461N transmitter with Profinet

The interface enables continuous communication of process variables and predictive maintenance from the field level to all common process control systems.

Stratos Multi E401X- Multiparameter Transmitter for Hazardous Locations

The new Multiparameter Transmitter Stratos Multi E401X can now also be used in hazardous locations, installed in Ex Zone 2.

The Big Three of the Process Industry: HART, FF, Profibus

Our Knick multi-parameter analyzers are now available with Profibus and FF interfaces. Even for hazardous areas.