Product added to compare
Product Compare added Product Compare

High voltage transducers featuring long-term stability, transducers, and signal multipliers for advanced applications

The robust, conservatively arranged circuit design of our products guarantees stable operations over the long term with a device-dependent MTBF (mean time between failures) of up to 2,165 years. Meticulous product development, extensive design verification, and 100% routine testing ensure the high quality of our products.

International certifications such as UL, CSA, CE, DNV, SIL, KTA, and ATEX allow the device to be used globally in a variety of applications. Our signal conditioners and transducers offer crucial advantages for applications with high demands placed on insulation, signal transmission speed, and long-term stability.

From high voltage measurement to measured value display

Current, voltage, and temperature measurement with high insulation; high-precision measurement for billing DC energy; detection of applied voltages
Active and passive signal conditioners for current and voltage measurement, standard signal conditioning, and supplying 2-wire sensors and repeater power supplies with average insulation.
Measurement of speed, temperature, strain, force, resistance, shunt voltages, and threshold value monitoring with low isolation.
Doublers, converters, and conditioners of speed sensor signals with high EMC, doublers and quadruplers of standard signals.
Loop-powered digital indicators for panel mounting or in a separate housing.
Transducers for high voltage and current measurement in railway applications.
Product Overview


Download the product brochure: With its comprehensive range of signal conditioners and transducers, Knick offers solutions that meet the highest standards of safety, precision, robustness and durability.

Product Highlights

P45000 High Voltage Transducer | Input up to ±3000 V overrange up to 150% | For use in SIL2 systems, redundantly in SIL3
Product number:

P45000

Input: 0 ... (±)2000 V, 0 ... (±)1000 V, 0 ... (±)2800 V, 0 ... (±)3000 V, Overrange up to 150 %, 0 ... (±)500 V, 0 ... (±)750 V, 0 ... (±)1500 V

Isolation AC/DC: up to 3,600 V AC, 4,800 V DC

P16800 Speed Signal Doubler | Input speed sensor signal 10 … 33.6 V DC (max.35 V) | Safe decoupling acc. SIL4, safe transmission acc. SIL2
Product number:

P16800

Input: Speed sensor signals 10 ... 33.6 V DC (max. 35 V) with Low: < 30 %, High: > 70 %, Speed sensor signals 6/7 ... 14/20 mA (max. 200 mA) with Low: < 8.5 mA, High: > 12.5 mA

Isolation AC/DC: up to 1,000 V

P41000AG High Voltage Transducer | Input up to ±120/1320 mV | Nominal current and overcurrent measurement
Product number:

P41000AG

Input: 0 ... (±)30/330 mV up to 0 ... (±)120/1320 mV

Isolation AC/DC: up to 3,600 V

P52000 VPD High Voltage Transducer | Input max. 4200 V DC or AC peak | Voltage presence detection
Product number:

P52000VPD

Input: 50 V ... 4200 V, 0 ... (±)100 V up to 0 ... (±)4800 V, max. 4800 V DC or AC peak

Isolation AC/DC: up to 4,800 V

P42000 High Voltage Transducer | Calibrated range selection
Product number:

P42000

Input: 0 ... (±)100 V up to 0 ... (±)3600 V

Isolation AC/DC: 2,200 V, up to 3,600 V

P42000 TRMS AC/DC High Voltage Transducer | Input up to ±3600 V | True RMS measurement
Product number:

P42000TRMS

Input: 0 ... 3600 V AC, 0 ... 10 V AC

Isolation AC/DC: 2,200 V, up to 3,600 V

Galvanic Isolation up to 6.6 kV

In industrial applications, measuring and control signals must be isolated when being transmitted – for safety reasons and in order to achieve optimal signal quality. The products used must safely master dangerously high voltage levels, a variety of groundpotentials and high common-mode voltages.

Knick's transducers and signal converters galvanically isolate the 3-ports of the input, output, and power supply from each other as standard for up to 6.6 kV of continuous isolation. The 3-port isolation reliably protects against measurement errors caused by grounding problems and interference voltage transmissions.

We look forward hearing from you!
Contact Us

Accuracy

Intelligent circuit design and integrated safety margins between the normal load and the possible maximum load in the event of an error are basic design principles employed by Knick. They also include the use of high-quality parts and eliminating components with high failure rates. Knick signal conditioners are designed not only to operate reliably under normal conditions, but also to perform their function safely under extreme operating conditions. The advantages can be found in every detail.

P45000 High Voltage Transducer | Input up to ±3000 V overrange up to 150% | For use in SIL2 systems, redundantly in SIL3
Product number:

P45000

Input: 0 ... (±)2000 V, 0 ... (±)1000 V, 0 ... (±)2800 V, 0 ... (±)3000 V, Overrange up to 150 %, 0 ... (±)500 V, 0 ... (±)750 V, 0 ... (±)1500 V

Isolation AC/DC: up to 3,600 V AC, 4,800 V DC

P52000 VPD High Voltage Transducer | Input max. 4200 V DC or AC peak | Voltage presence detection
Product number:

P52000VPD

Input: 50 V ... 4200 V, 0 ... (±)100 V up to 0 ... (±)4800 V, max. 4800 V DC or AC peak

Isolation AC/DC: up to 4,800 V

P42000 High Voltage Transducer | Calibrated range selection
Product number:

P42000

Input: 0 ... (±)100 V up to 0 ... (±)3600 V

Isolation AC/DC: 2,200 V, up to 3,600 V

P29000 High Voltage Transducer | Calibrated range selection
Product number:

P29000

Input: 0 ... (±)30 mV up to 0 ... (±)100 V, 0 ... (±)100 V up to 0 ... (±)1000 V

Isolation AC/DC: up to 1,000 V

P43000 TRMS AC/DC High Voltage Transducer | Input up to ±5 A | True RMS measurement
Product number:

P43000TRMS

Input: 0 ... 5 A AC, 0 ... 100 mA AC

P43000 High Voltage Transducer | Input up to ±5 A | Direct measurement
Product number:

P43000

Input: 0 ... (±)0.1 A upt to 0 ... (±)5 A

Isolation AC/DC: up to 3,600 V

BL591 Universal Isolated Signal Conditioners | Input up to ±1000 mV | Passive current output | Isolation up to 500 V
Product number:

BL591

Input: 0 ... (±)30 mV up to 0 ... (±)1000 mV

Isolation AC/DC: up to 500 V

P51000 High Voltage Transducer | Input up to ±125 V | Current measurement | Energy metering
Product number:

P51000

Input: 0 ... (±)30 mV up to 0 ... (±)100 V

Isolation AC/DC: up to 4,800 V

P16800 Speed Signal Doubler | Input speed sensor signal 10 … 33.6 V DC (max.35 V) | Safe decoupling acc. SIL4, safe transmission acc. SIL2
Product number:

P16800

Input: Speed sensor signals 10 ... 33.6 V DC (max. 35 V) with Low: < 30 %, High: > 70 %, Speed sensor signals 6/7 ... 14/20 mA (max. 200 mA) with Low: < 8.5 mA, High: > 12.5 mA

Isolation AC/DC: up to 1,000 V

P41000AG High Voltage Transducer | Input up to ±120/1320 mV | Nominal current and overcurrent measurement
Product number:

P41000AG

Input: 0 ... (±)30/330 mV up to 0 ... (±)120/1320 mV

Isolation AC/DC: up to 3,600 V

Shunt resistors | High overload capacity | Immune to stray fields
Product number:

maconic

Input: 0 ... 1 A up to 0 ... 20 kA

P41000 High Voltage Transducer | Input up to ±100 V | High isolation up to 3600 V
Product number:

P41000

Input: 0 ... (±)50 mV up to 0 ... (±)100 V

Isolation AC/DC: up to 3,600 V

A26000 Universal Isolated Signal Conditioner | Input 0…±20 mA or 0…±10 V | Current and voltage measurement
Product number:

A26000

Input: 0 ... (±)10 V, 0 ... (±)20 mA

Isolation AC/DC: up to 1,000 V

P44000 Temperature Transmitter | Input Pt100 resistance thermometer (RTD) | High isolation up to 6600V
Product number:

P44000

Input: 0 ... 100 °C, 0 ... 300 °C, 0 ... 200 °C

Isolation AC/DC: up to 2,000 V, up to 6,600 V

P27000 Universal Isolated Signal Conditioner | Calibrated switching of 480 input and output ranges | Isolation up to 1000 V
Product number:

P27000

Input: 4 ... 20 mA, 0 ... (±)10 V, 0 ... (±)0.1 mA up to 0 ... (±)100 mA, 0 ... (±)20 mA, 0 ... (±)20 mV up to 0 ... (±)200 V

Isolation AC/DC: up to 1,000 V

BL590 Universal Isolated Signal Conditioners | Input up to ±500 V | Passive current output | Isolation up to 500 V
Product number:

BL590

Input: 0 ... (±)50 V up to 0 ... (±)500 V

Isolation AC/DC: up to 500 V

P52000 High Voltage Transducer | Input up to ±4800 V | Voltage measurement | Energy metering
Product number:

P52000

Input: 0 ... (±)100 V up to 0 ... (±)4800 V

Isolation AC/DC: up to 4,800 V

P41000 TRMS AC/DC High Voltage Transducer | Input up to ±100 V | True RMS measurement
Product number:

P41000TRMS

Input: 0 ... 10 V AC, 0 ... 50 mV AC

P42000 TRMS AC/DC High Voltage Transducer | Input up to ±3600 V | True RMS measurement
Product number:

P42000TRMS

Input: 0 ... 3600 V AC, 0 ... 10 V AC

Isolation AC/DC: 2,200 V, up to 3,600 V