Product added to compare
Product Compare added Product Compare

SE680 Digital Toroidal Conductivity Sensor | For ARF 210/215 | FDA-approved PEEK | Measuring range 0 … 2000 mS/cm

Description

SE680 Digital Toroidal Conductivity Sensor | For ARF 210/215 | FDA-approved PEEK | Measuring range 0 … 2000 mS/cm

High-precision sensor made of FDA-approved PEEK with an extremely large measuring range. Steam-sterilizable.

High-precision sensor made of FDA-approved PEEK with an extremely large measuring range. Steam-sterilizable.

  • Compact design
  • Competitively priced
  • Large measuring range
  • Quick-reacting temperature detector
  • Digital data transfer
  • Completely closed surface
  • Virgin PEEK, FDA type
  • Varivent with EHEDG

The joint- and gap-free, sealless design and stain-resistant surface made of Virgin PEEK make the SE680 a heavy-duty sensor. The inductive technology is not influenced by polarization and does not have any sensor surfaces subject to corrosion.

Applications
Fresh water technology, dairy products, breweries, soft drink manufacturing, electroplating, air-conditioning, CIP monitoring in the beverage industry, pharmaceutical applications, cooling tower monitoring, on-site wastewater treatment plants, monitoring concentrations of salt solutions, alkalis and acids, washers, and rinsing processes

  • Compact design
  • Competitively priced
  • Large measuring range
  • Quick-reacting temperature detector
  • Digital data transfer
  • Completely closed surface
  • Virgin PEEK, FDA type
  • Varivent with EHEDG

Nous attendons avec impatience votre réponse!
Nous Contacter

Détails techniques

Error: ± 1 % d. m. + 0,002 mS/cm, ± 0,02 %/K
Facteur de cellule: c ≈ 5,0/cm
Matériaux en contact avec le milieu: Virgin PEEK, type FDA
Matériaux sans contact avec le milieu: PP-ESD
Paramètres de mesure: conductivité (induktive)
Plage de mesure: 0 … 2000 µS/cm
Principe de mesure: Inductif
Protection contre les explosions: pas d'Ex
Raccordement process: für ARF 210/215
Raccordement électrique: Connecteur M12 – 4 pôles Longueur de câble max. 100 m
Sonde de température: Pt1000
Temps de réponse: t90 < 30s
Transmission du signal: numérique
Relative process pressure: -0,1 ... 10 bar (cf. diagramme pression-température)
Sterilization: ≤ 5 bar / ≤ 150 °C / ≤ 60 min

Téléchargements

Manuals

[12413] Manuel utilisateur
SE680 (N/X)
Version 08

Brochures

[13395] Brochure
Sondes - Pour la mesure du pH/redox, de la conductivité et de l’oxygène. Numérique et analogique.

Fiches techniques

[2993 Fiche technique
Sonde de conductivité inductive SE680
Description du produit | Caractéristiques techniques | Gamme de produits

Notre service

Lorem lorem ipsum ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet. Lorem ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet.

Utilisé dans les processus ou les applications

In pharmaceutical, biological or process systems for food production, all process-wetted system components must be cleaned and sterilized at regular intervals…
The taste and quality of beer greatly depend on the quality of the water used to brew it. pH and conductivity measurements determine its quality. Globalization is putting massive competitive pressure…

Produits apparentés

Articles de blog pertinents

pH and conductivity measurement in vaccine production

Pharmaceutical contract manufacturer relies on Knick's transmitters for modular production plants for Covid-19 vaccines.

Sturdy 2-Electrodes Conductivity Sensor SE625 with Coaxial Electrodes made of Titanium

The SE625 ensures reliable and accurate determination of the conductivity of ultrapure water in the semiconductor industry.

SE655X numérique et SE656X numérique – Sondes de conductivité numériques avec certification Ex

SE655X numérique et SE656X numérique avec rapport Memosens sont disponibles avec une certification Ex. Elles sont particulièrement adaptées à l’industrie chimique, du papier et de la cellulose ainsi qu'à la surveillance des eaux usées industrielles.

Nouvelle sonde de conductivité numérique SE656N

New toroidal Digital Conductivity Sensor with a large measuring range and consisting of PFA for using in aggressive media

High-Precision Conductivity Measurement at Extreme Temperature Differences

Pharmaceutical manufacturer, EVER Pharma Jena uses the extremely robust conductivity sensors SE605(H) and SE680 with Memosens technology from Knick.