Passer au contenu principal

Unical 9000 Electro-pneumatic controller | For automatic cleaning and calibration | Hygienic Surface

Description

Unical 9000 Electro-pneumatic controller | For automatic cleaning and calibration | Hygienic Surface

Maximum availability of the point of measurement: Cleaning without interrupting the process, even when measuring directly in the pressure tank

  • hygienic version (polished stainless steel)
  • consistent enclosure concept for all devices.
  • modular design, adaptable to virtually every measuring task
  • easy assembly and retrofitting
  • tidy hose guiding
  • no entrainment and backmixing due to separate routing of the media
  • low maintenance effort due to innovative pump technology and extremely low consumption of media
  • automatic 2-point calibration
  • time-controlled cleaning and checking
  • cleaning with water and additional cleaning solution
  • reduced maintenance effort due to automatic calibration
  • no interruptions in production for calibration
  • longer sensor life due to short-time measurement and regular cleaning
  • immediate readiness for measurement after production interruption since sensor is safely stored in liquid
  • safety ensured by monitoring of the compressed air and water supply, the probe position and the buffer and cleaning solution level

In combination with the Protos process analysis system and a SensoGate or Ceramat sensor lock-gate, Unical provides the ideal functionality of a complete system for automatic process control of a pH measurement. 

It allows highly accurate measurements to be taken even with difficult process conditions such as high pressure, high temperatures, and high levels of impurities. The system can be installed next to the process, within the hazardous area.

Since the electrode is not removed for calibration, the process can continue uninterrupted. This allows problem-free measurements directly in a pressure vessel or in the main pipe. Elaborate and lockable bypasses are eliminated and accuracy increases.

Low maintenance
Fully automatic sensor calibration at user-defined intervals without interrupting the process. Two buffer solutions are automatically pumped into the calibration chamber. Only the buffer bottles need to be refilled.

Cost-effective
Low-wear and low-maintenance pumps with extremely low consumption of buffer.

Safe and easy measurement even in strongly polluted media
Sensor cleaning and rinsing is performed at user-defined intervals. Cleaning solution and water are automatically pumped into the calibration chamber. Removal and manual cleaning of the sensor are not required.

Distinction between calibration and adjustment
This allows you to check the sensor data in the running process. An adjustment is only carried out when there are preset deviations of the calibration values. Constant displacement of the measured values due to small calibration scatters is omitted.

Modern fieldbus integration
The interfaces to PROFIBUS PA or Foundation Fieldbus allow the Unical system to be integrated directly in a fieldbus network. Of course, also in hazardous areas.

Universal adaptation to retractable fittings
The modular structure of the Unical system allows any retractable fittings to be used. Optimum functionality is achieved with the Ceramat and Sensogate sensor lock-gates.

Clean and safe construction
All features for smooth, safe, and low-maintenance operation are included as standard: water pressure gage and service switch with alert message and feedback of the actual lock-gate position, air filter and water trap. Flooding sensor in the housing with alert message.

Nous attendons avec impatience votre réponse!
Nous Contacter

Détails techniques

Boîtier: Acier inox A2, poli
Dimensions (l x H x P): env. 320 x 400 x 120 mm
Paramètres de mesure: pH/potentiel redox
Protection: IP 65/NEMA 4X
Protection contre les explosions: pas d'Ex

Téléchargements

Manuals

[14190] User Manual
ZU 0741 (PFA, PVDF, PTFE)
Chemical Pump for Probe Controllers Uniclean 900(X), Unical 9000(X)
Version 03
[14286] User Manual
ZU 0812/*, ZU 1067/*
ZU 0812/* Multiplug Bottom Section Conversion Kit / ZU 1067/* Multiplug Middle Section Conversion Kit
Version 02
[17320] Manuel utilisateur
Unical 9000/Protos II 4400
Version 02
[14145] User Manual
ZU 0741/1 (PTFE, stainless steel (1.4408, 1.4401)
Chemical Pump for Probe Controllers Uniclean 900(X), Unical 9000(X)
Version 04

Fiches techniques

[3998] Data sheet
Unical 9000
Product Description | Specifications | Product Range

Certificats

[13931] EU Declaration of Conformity (DE, EN, FR)
No. EU230413B | 2023-04-21
Unical 9000-N | Uniclean 900-N

Notre service

Utilisé dans les processus ou les applications

Mesure du pH dans le dispositif de prélavage, lors de la neutralisation et du lavage à la chaux dans le cadre du process de désulfuration des fumées dans les centrales électriques.

Produits apparentés

Articles de blog pertinents

Sturdy 2-Electrodes Conductivity Sensor SE625 with Coaxial Electrodes made of Titanium

The SE625 ensures reliable and accurate determination of the conductivity of ultrapure water in the semiconductor industry.

Combined pH- and ORP-Sensor SE555X/*-AMSN

Combined pH and ORP measurement in one sensor SE555 saves place and equipment costs for demanding requirements in the chemical industry, the food sector and for hygienic applications.

SE655X numérique et SE656X numérique – Sondes de conductivité numériques avec certification Ex

SE655X numérique et SE656X numérique avec rapport Memosens sont disponibles avec une certification Ex. Elles sont particulièrement adaptées à l’industrie chimique, du papier et de la cellulose ainsi qu'à la surveillance des eaux usées industrielles.

Nouvelle sonde de conductivité numérique SE656N

New toroidal Digital Conductivity Sensor with a large measuring range and consisting of PFA for using in aggressive media

How to get the sensor into the process

Sensors as the direct interface to the process must be exactly matched to the chemistry of the measured medium and to the prevailing pressure and temperature conditions.