Passer au contenu principal

SE555 pH Sensor | Memosens | 120 mm | Ex | Sterilizable | For aggressive media

Description

SE555 pH Sensor | Memosens | 120 mm | Ex | Sterilizable | For aggressive media

Digital, sterilizable pH sensor providing high reliability and precision.

  • Gel electrolyte, pressurized
  • Ceramic junction
  • Silver ion trap
  • Integrated temperature detector
  • pH glass with high impedance for high-temperature applications, low alkali error
  • CIP/SIP-capable, safe sterilization with temperature monitoring
  • Perfect galvanic isolation thanks to Memosens technology
  • No influence of humidity in the connector
  • Precalibration in the lab
  • Digital data transfer
  • Integrated sensor diagnostics

The SE555 digital pH sensor comes with a special pH glass with high impedance for high-temperature applications and a low alkali error. The sensor is CIP- and SIP-capable. The silver ion trap prevents silver sulfide precipitation and junction fouling in media containing sulfides.

This makes the sensor ideal for routine applications in food processing and biotechnology. Additionally the Memosens technology offers all well known advantages concerning operation and sensor diagnostics.

Applications
Fermentation, food and beverages, aggressive media, extreme pH values

Nous attendons avec impatience votre réponse!
Nous Contacter

Détails techniques

Diaphragme: Céramique, 1x
Longueur : 120 mm
Paramètres de mesure: pH
Plage de mesure: 0 … 14 pH
Pression relative: -1 … 6 bar
Protection contre les explosions: Ex
Raccordement process: PG 13,5
Sonde de température: NTC 30 kΩ
Système de référence: Ag/AgCl avec barrière aux ions argent
Température: 0 … 135 °C
Tête enfichable: Memosens
Verre pH: Omega glass, high impedance, low alkali error
Électrolyte : Prepressurized gel electrolyte

Téléchargements

Manuals

[16286] User Manual (DE, EN, KO)
Memosens Cable CA/MS
Version 09
[12389] Manuel utilisateur
SE555X/*-AMSN | -NMSN | -NVPN | -NS8N
Version 04
[14165] User Manual (DE, EN)
ZU 1054 Sensor Protection (Sensorschutz)

Brochures

[13209] Brochure
Memosens - La solution complète pour des applications de mesure intelligentes.
[13395] Brochure
Sondes - Pour la mesure du pH/redox, de la conductivité et de l’oxygène. Numérique et analogique.

Fiches techniques

[2502] Fiche technique
Électrode pH SE555X/*-NMSN(-LABS) Memosens
Description du produit | Caractéristiques techniques | Gamme de produits

Certificats

[14690] Certificate of Conformity (FM)
No. FM17CA0105X | 2019-05-27 | Canada
Memosens Sensors | Types SE 5**, SE 6** and SE 7**
[13263] Declaration of Conformity
Cytotoxicity of the Test Material "Electrolyte gel Rheolid" | 2010-08-02
SE 555X/.-NMSN
[11064] EU Declaration of Conformity
No. EU210427A | 2021-04-27
Memosens Sensors | Types SE 5..X..-.MS., SE604X-MS**, SE605….., SE6**X**MS, SE7**…
[14685] Certificate of Conformity (FM)
No. FM17US0208X | 2019-05-27 | USA
Memosens Sensors | Types SE 5**, SE 6** and SE 7**
[17427] Type Examination Certificate for Ex-Equipment (Japan)
No. CML 20JPN2077X | from 10-07-2020 to 09-07-2023
MEMOSENS CA/MS-***X**-JP
[12113] Confirmation (DE, EN)
Kein tierischer Ursprung / No components of animal origin
Series SE 555X/*-*MS*, SE555X/*-*VP*, SE 555X/*-*S8
[16639] Type Approval Certificate for Ex-Equipment (JA)
No. DEK19.0046X, Issue No. 0 (Japan)
SE5**X/*-*MSN | SE7**X/*-*MSN
[16292] Korean safety certificate Kosha (KO)
No. 2020-KA4BO-0368X
Measuring Cable CA/MS
[16262] Korean safety certificate Kosha (KO)
No. 2020-KA4BO-0355X
SE55*Xl*-NMSN, SE605H-XMS****
[12826] EU-Type Examination Certificate (DEKRA)
Nr. BVS 16 ATEX E 037 X | 2024-02-20
Memosens-Ex-Sensors
[12831] IECEx Certificate of Conformity
Memosens Ex Sensors | Details see Document
Document No. IECEx BVS 16.0030X, issue No. 2 | 2024-02-23
Marking: Ex ia IIC T3/T4/T6 Ga
[14155] Declaration of Compliance 2.1 (DE, EN)
according to EN 10204 | gemäß EN 10204

Safety guides

[11048] Fiche de sécurité
Solution tampon CaliMat pH 4,00
[11049] Fiche de sécurité
Solution tampon CaliMat pH 2,00
[11045] Fiche de sécurité
Solution tampon CaliMat pH 7,00
[11046] Fiche de sécurité
Solution tampon CaliMat pH 9,00
[11044] Fiche de sécurité
Solution tampon CaliMat pH 12,00

Schémas de Contrôle

[14185] Control Drawing
Inductive Sensor-Cable Connection System Memosens
Zeichnungsnummer 214.410-240

Notre service

Utilisé dans les processus ou les applications

Mesure du pH, du potentiel redox et de la conductivité de l’eau de refroidissement, qui doit continuellement être traitée avec des acides et des biocides.
Le goût et la qualité de la bière dépendent en grande partie de la qualité de l’eau. Celle-ci est déterminée par des mesures du pH et de la conductivité.
La production de sucre expose les sondes pH à des contraintes extrêmes. La surveillance du pH est utile dès le lavage des betteraves, puisque le dosage de la chaux dépend de sa mesure.
Les tours de refroidissement sont utilisées dans de multiples secteurs industriels pour évacuer la chaleur industrielle des circuits de refroidissement. Les dépôts minéraux et la corrosion diminuent l’efficacité et conduisent à l’usure prématurée des composants des installations.
High quality requirements are placed on raw milk, and online monitoring of truck unloading procedure at the dairy prevents inferior quality (sour milk) from spoiling the entire stock of the storage tank.

Produits apparentés

Articles de blog pertinents