Passer au contenu principal

SE557 pH Sensor | Memosens | 120 mm | Ex | Alpha glass | For process media requiring high measurement stability

Description

SE557 pH Sensor | Memosens | 120 mm | Ex | Alpha glass | For process media requiring high measurement stability

For special requirements and high-precision measurements with refillable liquid electrolyte, digital, with Memosens technology

  • Alpha glass, medium impedance, universal glass, fluoride resistant
  • High accuracy
  • Extensive measuring range for pH and temperature
  • Refillable liquid electrolyte
  • 2 ceramic junctions
  • Self cleaning due to pressurization
  • Integrated temperature detector
  • Perfect galvanic isolation thanks to Memosens technology
  • No influence of humidity in the connector
  • Precalibration in the lab
  • Digital data transfer
  • Integrated sensor diagnostics

Elimination of typical junction problems resulting in high measurement accuracy in ultrapure water as well as in heavily polluted media and at high temperatures. Integrated, refillable liquid electrolyte reservoir. 2 ceramic junctions, self cleaning due to pressurization (continuous outflow of electrolyte).

Nous attendons avec impatience votre réponse!
Nous Contacter

Détails techniques

Composition de l’électrode: verre Alpha
Diaphragme: Céramique, 2x
Longueur : 120 mm
Paramètres de mesure: pH
Plage de mesure: 0 … 14 pH
Pression relative: -1 … 6 bar
Protection contre les explosions: Ex
Sonde de température: NTC 30 kΩ
Système de référence: Ag/AgCl, électrolyte liquide, remplissable
Température: -20 … 100 °C
Tête enfichable: Memosens

Téléchargements

Manuals

Manuel utilisateur
Electrode pH SE557 (Memosens + VP)
Version 07
[16286] User Manual (DE, EN, KO)
Memosens Cable CA/MS
Version 09

Brochures

[13209] Brochure
Memosens - La solution complète pour des applications de mesure intelligentes.
[13395] Brochure
Sondes - Pour la mesure du pH/redox, de la conductivité et de l’oxygène. Numérique et analogique.

Fiches techniques

Fiche technique
SE557X/*-NMSN / NMSH
Description du produit | Caractéristiques techniques | Gamme de produits

Certificats

[14685] Certificate of Conformity (FM)
No. FM17US0208X | 2019-05-27 | USA
Memosens Sensors | Types SE 5**, SE 6** and SE 7**
[16639] Type Approval Certificate for Ex-Equipment (JA)
No. DEK19.0046X, Issue No. 0 (Japan)
SE5**X/*-*MSN | SE7**X/*-*MSN
[16292] Korean safety certificate Kosha (KO)
No. 2020-KA4BO-0368X
Measuring Cable CA/MS
[11064] EU Declaration of Conformity
No. EU210427A | 2021-04-27
Memosens Sensors | Types SE 5..X..-.MS., SE604X-MS**, SE605….., SE6**X**MS, SE7**…
[14690] Certificate of Conformity (FM)
No. FM17CA0105X | 2019-05-27 | Canada
Memosens Sensors | Types SE 5**, SE 6** and SE 7**
[16262] Korean safety certificate Kosha (KO)
No. 2020-KA4BO-0355X
SE55*Xl*-NMSN, SE605H-XMS****
[12826] EU-Type Examination Certificate (DEKRA)
Nr. BVS 16 ATEX E 037 X | 2024-02-20
Memosens-Ex-Sensors

Safety guides

[11049] Fiche de sécurité
Solution tampon CaliMat pH 2,00
[11048] Fiche de sécurité
Solution tampon CaliMat pH 4,00
[11045] Fiche de sécurité
Solution tampon CaliMat pH 7,00
[11046] Fiche de sécurité
Solution tampon CaliMat pH 9,00
[11044] Fiche de sécurité
Solution tampon CaliMat pH 12,00

Schémas de Contrôle

[14185] Control Drawing
Inductive Sensor-Cable Connection System Memosens
Zeichnungsnummer 214.410-240

Notre service

Utilisé dans les processus ou les applications

Knick propose des transmetteurs industriels innovants, des sondes de haute qualité, des supports innovants, ainsi que des systèmes de nettoyage et de calibrage uniques en leur genre.
Mesure du pH dans le dispositif de prélavage, lors de la neutralisation et du lavage à la chaux dans le cadre du process de désulfuration des fumées dans les centrales électriques.

Produits apparentés

Articles de blog pertinents

Stack and String Voltage Measurement in Electrolyzers and Fuel Cells

Voltage, current and temperature measurement in electrolyzers with P40000 series high voltage transducers

Des nouvelles résistances shunt de 30 mV pour les convertisseurs de mesure de Knick

Knick agrandit dès à présent sa gamme d’accessoires prévue pour les convertisseurs haute tension de résistances shunt avec chute de tension de 30 mV
Innovations at InnoTrans 2024

Innovations at InnoTrans 2024 for rolling stock and DC traction power supply

At InnoTrans 2024 Knick presents electrical measurement solutions for rolling stock and DC traction power supply applications

Knick Austria - direct customer contact in Austria from 2024

Reorganization of sales in Austria and new contacts in the field of process analytics and interface technology

Energy storage - the handshake between renewable energy and electric vehicles

Energy storage technology such as battery and hydrogen are critical for growth and continuous development of renewable energy and e-mobility.

Le détecteur de tension P52000VPD assure une détection fiable des tensions jusqu'à 4200 V DC

Le nouveau détecteur de tension P52000VPD (Voltage Presence Detection) assure une surveillance fiable des zones à haute tension et envoie un signal à la commande de l'installation en aval lorsqu'une valeur seuil définie est atteinte.

Knick Interface at Battery and Electric & Hybrid Vehicle Technology Expo

Knick will be showcasing high-voltage electrical measurement and signal conversion products.

VariTrans A20340 - Multiplication des signaux normalisés dans un seul amplificateur séparateur

The A20340 can output a standard input signal to four calibrated and galvanically isolated outputs in parallel.

Electrical measurement and process analytics for hydrogen production

Knick products optimize hydrogen production in the process and in electrolyser operation.

Condition Monitoring of High-Voltage Motors

Having an active predictive maintenance campaign in place for large rotating equipment can be a key strategy for maximizing process uptime.

Convertisseur de fréquence pour capteurs de vitesse

The new P16000 from Knick is a pulse frequency conditioner that converts frequency signals from speed sensors into standard signals.

Le convertisseur le plus compact du monde jusqu’à ±2200 V

La série VariTrans P 40000 de Knick permet de réaliser des mesures de tension fiables de ±50 mV jusqu’à ±3600 V et des mesures de courant de ±100 mA jusqu’à ±20 kA. Cette série ProLine éprouvée accueille à présent le convertisseur P42000D2.

L’importance des systèmes d’alimentation à large spectre pour les mesures électriques DC

De nombreux instruments de mesure électrique DC fabriqués par Knick comprennent une alimentation universelle, ou à large spectre. Cela signifie qu’ils fonctionnent avec un spectre relativement large de tension, par exemple 20…253 V, AC ou DC.

Mesure de la dégradation photovoltaïque

L’ampleur de la dégradation photovoltaïque (PV) est un élément important à prendre en compte pour la conception et l’installation de systèmes. Des facteurs tels que la météo et l’exposition aux UV contribuent au déclin de la performance.

Solutions de mesures électriques : Contrôles de 480 à 4800 Volts

Les transducteurs de tension de Knick permettent un contrôle réel aux applications de mesures électriques dans un vaste éventail de secteurs.

Les avantages des transducteurs haute tension par rapport aux transformateurs de mesure

Les transformateurs ont longtemps été considérés comme des composants importants des systèmes électriques. Il ne fait aucun doute que ces appareils sont essentiels.

Shunt Resistor versus Hall Effect Technology

There are many systems where measurement of large DC currents are needed for performance and safety.

MTBF beyond 3000 years: A snap hook for your plant

Failure of equipment on the plant floor can lead to considerable and costly disruption.

Knick Products Comply With UL - What Does That Mean?

There are different assessments and approaches to reach an adequate level of safety. Manufacturers are typically on the “safe” side, if they comply with recognized standards.

High-voltage transducer offers more safety on railway vehicles

The requirements placed on railway vehicles have increased significantly in recent years. Products for rolling stock need to ensure a higher level of functional safety than ever before.

True RMS Measurement with P41000TRMS

Traditional millivolt AC transducers are very susceptible to errors due to their poor insulation and are only designed for pure sinewave measurement.

Functional safety and maximum availability can go together

The requirements on operational and safety-related circuits are continuously growing.