Passer au contenu principal

SE557 pH Sensor | Memosens | 120 mm | Ex | Alpha glass | For process media requiring high measurement stability

Description

SE557 pH Sensor | Memosens | 120 mm | Ex | Alpha glass | For process media requiring high measurement stability

For special requirements and high-precision measurements with refillable liquid electrolyte, digital, with Memosens technology

  • Alpha glass, medium impedance, universal glass, fluoride resistant
  • High accuracy
  • Extensive measuring range for pH and temperature
  • Refillable liquid electrolyte
  • 2 ceramic junctions
  • Self cleaning due to pressurization
  • Integrated temperature detector
  • Perfect galvanic isolation thanks to Memosens technology
  • No influence of humidity in the connector
  • Precalibration in the lab
  • Digital data transfer
  • Integrated sensor diagnostics

Elimination of typical junction problems resulting in high measurement accuracy in ultrapure water as well as in heavily polluted media and at high temperatures. Integrated, refillable liquid electrolyte reservoir. 2 ceramic junctions, self cleaning due to pressurization (continuous outflow of electrolyte).

Nous attendons avec impatience votre réponse!
Nous Contacter

Détails techniques

Composition de l’électrode: verre Alpha
Diaphragme: Céramique, 2x
Longueur : 120 mm
Paramètres de mesure: pH
Plage de mesure: 0 … 14 pH
Pression relative: -1 … 6 bar
Protection contre les explosions: Ex
Sonde de température: NTC 30 kΩ
Système de référence: Ag/AgCl, électrolyte liquide, remplissable
Température: -20 … 100 °C
Tête enfichable: Memosens

Téléchargements

Manuals

Manuel utilisateur
Electrode pH SE557 (Memosens + VP)
Version 07
[16286] User Manual (DE, EN, KO)
Memosens Cable CA/MS
Version 09

Brochures

[13209] Brochure
Memosens - La solution complète pour des applications de mesure intelligentes.
[13395] Brochure
Sondes - Pour la mesure du pH/redox, de la conductivité et de l’oxygène. Numérique et analogique.

Fiches techniques

Fiche technique
SE557X/*-NMSN / NMSH
Description du produit | Caractéristiques techniques | Gamme de produits

Certificats

[14685] Certificate of Conformity (FM)
No. FM17US0208X | 2019-05-27 | USA
Memosens Sensors | Types SE 5**, SE 6** and SE 7**
[16639] Type Approval Certificate for Ex-Equipment (JA)
No. DEK19.0046X, Issue No. 0 (Japan)
SE5**X/*-*MSN | SE7**X/*-*MSN
[16292] Korean safety certificate Kosha (KO)
No. 2020-KA4BO-0368X
Measuring Cable CA/MS
[11064] EU Declaration of Conformity
No. EU210427A | 2021-04-27
Memosens Sensors | Types SE 5..X..-.MS., SE604X-MS**, SE605….., SE6**X**MS, SE7**…
[14690] Certificate of Conformity (FM)
No. FM17CA0105X | 2019-05-27 | Canada
Memosens Sensors | Types SE 5**, SE 6** and SE 7**
[16262] Korean safety certificate Kosha (KO)
No. 2020-KA4BO-0355X
SE55*Xl*-NMSN, SE605H-XMS****
[12826] EU-Type Examination Certificate (DEKRA)
Nr. BVS 16 ATEX E 037 X | 2024-02-20
Memosens-Ex-Sensors

Safety guides

[11049] Fiche de sécurité
Solution tampon CaliMat pH 2,00
[11048] Fiche de sécurité
Solution tampon CaliMat pH 4,00
[11045] Fiche de sécurité
Solution tampon CaliMat pH 7,00
[11046] Fiche de sécurité
Solution tampon CaliMat pH 9,00
[11044] Fiche de sécurité
Solution tampon CaliMat pH 12,00

Schémas de Contrôle

[14185] Control Drawing
Inductive Sensor-Cable Connection System Memosens
Zeichnungsnummer 214.410-240

Notre service

Utilisé dans les processus ou les applications

Knick propose des transmetteurs industriels innovants, des sondes de haute qualité, des supports innovants, ainsi que des systèmes de nettoyage et de calibrage uniques en leur genre.
Mesure du pH dans le dispositif de prélavage, lors de la neutralisation et du lavage à la chaux dans le cadre du process de désulfuration des fumées dans les centrales électriques.

Produits apparentés

Articles de blog pertinents

Sturdy 2-Electrodes Conductivity Sensor SE625 with Coaxial Electrodes made of Titanium

The SE625 ensures reliable and accurate determination of the conductivity of ultrapure water in the semiconductor industry.

Combined pH- and ORP-Sensor SE555X/*-AMSN

Combined pH and ORP measurement in one sensor SE555 saves place and equipment costs for demanding requirements in the chemical industry, the food sector and for hygienic applications.

SE655X numérique et SE656X numérique – Sondes de conductivité numériques avec certification Ex

SE655X numérique et SE656X numérique avec rapport Memosens sont disponibles avec une certification Ex. Elles sont particulièrement adaptées à l’industrie chimique, du papier et de la cellulose ainsi qu'à la surveillance des eaux usées industrielles.

Nouvelle sonde de conductivité numérique SE656N

New toroidal Digital Conductivity Sensor with a large measuring range and consisting of PFA for using in aggressive media

How to get the sensor into the process