Stratos Pro A201 COND Conductivity Transmitter | Analog Sensors | HART | 2x 4 ... 20 mA Outputs

Description

Stratos Pro A201 COND Conductivity Transmitter | Analog Sensors | HART | 2x 4 ... 20 mA Outputs

2-wire analyzer for conductivity measurement

  • Digital communication: HART 
  • Two current outputs
  • Intuitive operation with color-coded user guidance
  • IP 66/67, NEMA 4X protection
  • Automatic sensor identification
  • Sensor diagnostic with wear indication, remaining lifetime, CIP/SIP counter and adaptive calibration timer
  • High-contrast widescreen display with colored backlighting
  • Protective pane made of safety glass
  • One analog input (4 ... 20 mA) e.g. for external pressure compensation
  • Two parameter sets
  • Two digital inputs: 
    • External HOLD activation
    • External switching between parameter set
  • Logbook (200 entries)
Outstanding properties
A number of outstanding technological properties make the Stratos Pro series the new benchmark for 2-wire analyzers. Colored screen backlighting has been implemented for the first time in this device class, with the lowest possible power consumption.
 
Wide Range of Functions
2 digital inputs are provided, as well as an analog input plus a second current output for another measured value. 

Nous attendons avec impatience votre réponse!
Nous Contacter

Détails techniques

2 ou 4 fils: 2 fils
Boîtier: Molded enclosure, PBT/PC, glass-reinforced
Canaux: 1 canal
Communication (Sortie numérique): HART
Gamme de produits: Stratos, Stratos Pro
Paramètres de mesure: conductivité (conductive)
Protection contre les explosions: pas d'Ex
Raccordement de la sonde: Analogue
Sorties de courant: 2x 4 … 20 mA
permanently installed / portable: permanently installed
Écran: Écran graphique couleur TFT 4,3", rétro-éclairé blanc

Téléchargements

Manuals

[3945] Manuel utilisateur
Stratos Pro A201 COND
Mesure de la conductivité avec des sondes conductives
Version 04
[13532] Transmitter Specific HART Command Specification
Stratos Evo A402 Cond / Stratos Pro A201 Cond
Device Revision: 5 (A402) & 3 (A201 Cond)
[13527] Transmitter Specific HART Command Specification
Stratos Pro A201 Cond / A401 Cond
Device Revision: 2
[17264] Transmitter Specific HART Command Specification
Stratos Pro A201 Cond
Device Revision: 4

Brochures

[14695] Brochure
Stratos Pro
2-wire analyzers for pH/ORP, conductivity or oxygen

Fiches techniques

[16180] Data sheet (EN)
Stratos Pro A201
Product Description | Specifications | Product Range

Certificats

[12917] Quality Control Certificate
Device Settings for Customer-Specific Buffer Solutions
Version 01

Safety guides

[7598] Safety Guide
Stratos Pro / MS / Evo Series
Installation and Use in Hazardous Locations
Version 05

Software

[12228] EDD (AMS)
Stratos Pro A201 Cond
Device Revision 02
[17252) EDD (PDM)
Stratos Pro A201 Cond
Device Revision 04
[13517] EDD (PDM)
Stratos Pro A201 Cond
Device Revision 03
[12216] EDD (PDM)
Stratos Pro A201 Cond
Device Revision 02
[13512] DTM (Pactware)
Stratos Pro A201 Cond
Device Revision 03
[12220] DTM (Pactware)
Stratos Pro A201 Cond
Device Revision 02
[18054] Software
KnUT (Knick Update Tool)

Notre service

Utilisé dans les processus ou les applications

Les tours de refroidissement sont utilisées dans de multiples secteurs industriels pour évacuer la chaleur industrielle des circuits de refroidissement. Les dépôts minéraux et la corrosion diminuent l’efficacité et conduisent à l’usure prématurée des composants des installations.

Produits apparentés

Articles de blog pertinents

Mesure de la dégradation photovoltaïque

L’ampleur de la dégradation photovoltaïque (PV) est un élément important à prendre en compte pour la conception et l’installation de systèmes. Des facteurs tels que la météo et l’exposition aux UV contribuent au déclin de la performance.