Stratos Pro A201 MSCONDI Inductive Conductivity Transmitter | Memosens Sensors | Ex Zone 0/1 | HART | 2x 4 ... 20 mA Outputs
Réf. produit :
A201X-MSCONDI-1
Description
Stratos Pro A201 MSCONDI Inductive Conductivity Transmitter | Memosens Sensors | Ex Zone 0/1 | HART | 2x 4 ... 20 mA Outputs
2-wire analyzer for conductivity measurement
- Intuitive operation with color-coded user guidance
- IP 66/67, NEMA 4X protection
- Automatic sensor identification
- Sensor diagnostic with wear indication, remaining lifetime, CIP/SIP counter and adaptive calibration timer
- High-contrast widescreen display with colored backlighting
- Protective pane made of safety glass
- One analog input (4 ... 20 mA) e.g. for external pressure compensation
- Two parameter sets
- Two digital inputs:
- External HOLD activation
- External switching between parameter set
- Logbook (200 entries)
Outstanding properties
A number of outstanding technological properties make the Stratos Pro series the new benchmark for 2-wire analyzers. Colored screen backlighting has been implemented for the first time in this device class, with the lowest possible power consumption.
A number of outstanding technological properties make the Stratos Pro series the new benchmark for 2-wire analyzers. Colored screen backlighting has been implemented for the first time in this device class, with the lowest possible power consumption.
Wide Range of Functions
2 digital inputs are provided, as well as an analog input plus a second current output for another measured value.
2 digital inputs are provided, as well as an analog input plus a second current output for another measured value.
Zone 1 Explosion Protection
Stratos Pro is designed for operation in Zone 1 / Class 1 Division 1 hazardous areas (with the sensor in Zone 0). Operation in hazardous areas from –20 °C to +65 °C is possible. The devices are designed for gas and dust explosion protection (G/D) and can naturally also be used outdoors (type 4 enclosure, UV resistant).
Stratos Pro is designed for operation in Zone 1 / Class 1 Division 1 hazardous areas (with the sensor in Zone 0). Operation in hazardous areas from –20 °C to +65 °C is possible. The devices are designed for gas and dust explosion protection (G/D) and can naturally also be used outdoors (type 4 enclosure, UV resistant).
Nous attendons avec impatience votre réponse!
Nous Contacter
2 ou 4 fils: | 2 fils |
---|---|
Boîtier: | Molded enclosure, PBT/PC, glass-reinforced |
Canaux: | 1 canal |
Communication (Sortie numérique): | HART |
Gamme de produits: | Stratos, Stratos Pro |
Paramètres de mesure: | conductivité (induktive) |
Protection contre les explosions: | Ex, hazardous area Zone 1 |
Raccordement de la sonde: | Memosens |
Sorties de courant: | 2x 4 … 20 mA |
permanently installed / portable: | permanently installed |
Écran: | Écran graphique couleur TFT 4,3", rétro-éclairé blanc |