2-wire analyzer for conductivity measurement

  • Extensive diagnostic functions with Memosens sensors
  • Explosion protection: Zone 1 / Class 1 Division 1 (with sensor in Zone)
  • Digital communication: HART 
  • Intuitive operation with color-coded user guidance
  • IP 66/67, NEMA 4X protection
  • Automatic sensor identification
  • Sensor diagnostic with wear indication, remaining lifetime, CIP/SIP counter and adaptive calibration timer
  • High-contrast widescreen display with colored backlighting
  • Protective pane made of safety glass
  • One analog input (4 ... 20 mA) e.g. for external pressure compensation
  • Two parameter sets
  • Two digital inputs: 
    • External HOLD activation
    • External switching between parameter set
  • Logbook (200 entries)
Outstanding properties
A number of outstanding technological properties make the Stratos Pro series the new benchmark for 2-wire analyzers. Colored screen backlighting has been implemented for the first time in this device class, with the lowest possible power consumption.
 
Wide Range of Functions
2 digital inputs are provided, as well as an analog input plus a second current output for another measured value. 
 
Zone 1 Explosion Protection
Stratos Pro is designed for operation in Zone 1 / Class 1 Division 1 hazardous areas (with the sensor in Zone 0). Operation in hazardous areas from –20 °C to +65 °C is possible. The devices are designed for gas and dust explosion protection (G/D) and can naturally also be used outdoors (type 4 enclosure, UV resistant).

Nous attendons avec impatience votre réponse!
Nous Contacter

Détails techniques

2 ou 4 fils: 2 fils
Boîtier: Molded enclosure, PBT/PC, glass-reinforced
Canaux: 1 canal
Communication (Sortie numérique): HART
Gamme de produits: Stratos, Stratos Pro
Paramètres de mesure: conductivité (induktive)
Protection contre les explosions: Ex, hazardous area Zone 1
Raccordement de la sonde: Memosens
Sorties de courant: 1x 4 … 20 mA
permanently installed / portable: permanently installed
Écran: Écran graphique couleur TFT 4,3", rétro-éclairé blanc

Téléchargements

Manuals

[17431] Quickstart (EN, JA)
Stratos Pro A201XMS COND
Version 03
[3939] Manuel utilisateur
Stratos Pro A201MSCONDI
Mesure de la conductivité avec des sondes inductives avec protocole Memosens
Version 04

Brochures

[13209] Brochure
Memosens - La solution complète pour des applications de mesure intelligentes.
[14695] Brochure
Stratos Pro
2-wire analyzers for pH/ORP, conductivity or oxygen

Fiches techniques

[16180] Data sheet (EN)
Stratos Pro A201
Product Description | Specifications | Product Range

Certificats

[8040] Certificate of Conformity (FM-Canada)
No. FM21CA0052 (Canada) | 2021-11-01
Stratos Pro Types A201X…, A211X…, A201B…, A221X… and A231X… | Stratos Multi Type E401X
[12932] EU Declaration of Conformity
No. EU210721B | 2021-07-21
for Stratos Pro Type A201X…
[17027] EU Type-Examination Certificate
No. KEMA 08ATEX0100 | 2024-03-07
Issue No. 10
Stratos Pro Types A201X…, A201X-*-0-T6, A211X…, A221X… and A231X… | Stratos Multi Type E401X
[16316] Certitficate of Conformity (China - Ex NEPSI)
Cert No. GYJ20.1052X | 2020-06-10
Stratos Pro A20..X / Multi E401X
[17021] IECEx Certificate of Conformity
No. IECEX KEM 08.0020
Issue No. 9 | 2024-03-07
Stratos Pro Types A201X…, A201X-*-0-T6, A211X…, A201B…, A221X…, A231X | Stratos Multi Type E401X
[12917] Quality Control Certificate
Device Settings for Customer-Specific Buffer Solutions
Version 01

Safety guides

[7598] Safety Guide
Stratos Pro / MS / Evo Series
Installation and Use in Hazardous Locations
Version 05

Schémas de Contrôle

[13098] Control Drawing
Measuring Module Type MK-CONDI035X
Zeichnungsnummer 212.002-140 page 1 rev.7
ATEX, IECEx, cFMus, INMETRO
[13038] Control Drawing
Stratos Pro Type A20.X…
Zeichnungsnummer 212.002-100 page 3 rev.7
INMETRO
[13043] Control Drawing
Stratos Pro Type A201X-*-0-T6
Zeichnungsnummer 212.002-100 page 5 rev.4
ATEX, IECEx

Software

[18054] Software
KnUT (Knick Update Tool)

Notre service

Utilisé dans les processus ou les applications

Les tours de refroidissement sont utilisées dans de multiples secteurs industriels pour évacuer la chaleur industrielle des circuits de refroidissement. Les dépôts minéraux et la corrosion diminuent l’efficacité et conduisent à l’usure prématurée des composants des installations.

Produits apparentés

Articles de blog pertinents

Mesure de la dégradation photovoltaïque

L’ampleur de la dégradation photovoltaïque (PV) est un élément important à prendre en compte pour la conception et l’installation de systèmes. Des facteurs tels que la météo et l’exposition aux UV contribuent au déclin de la performance.