Passer au contenu principal

Stratos Pro A201 OXY Oxygen Transmitter | Analog Sensors | Ex Zone 0/1 | HART | 2x 4 ... 20 mA Outputs

Description

Stratos Pro A201 OXY Oxygen Transmitter | Analog Sensors | Ex Zone 0/1 | HART | 2x 4 ... 20 mA Outputs

2-wire analyzer for oxygen measurement

  • Explosion protection: Zone 1 / Class 1 Division 1 (with sensor in Zone)
  • Two current outputs
  • Digital communication: HART 
  • Intuitive operation with color-coded user guidance
  • IP 66/67, NEMA 4X protection
  • Automatic sensor identification
  • Sensor diagnostic with wear indication, remaining lifetime, CIP/SIP counter and adaptive calibration timer
  • High-contrast widescreen display with colored backlighting
  • Protective pane made of safety glass
  • One analog input (4 ... 20 mA) e.g. for external pressure compensation
  • Two parameter sets
  • Two digital inputs: 
    • External HOLD activation
    • External switching between parameter set
  • Logbook (200 entries)
Outstanding properties
A number of outstanding technological properties make the Stratos Pro series the new benchmark for 2-wire analyzers. Colored screen backlighting has been implemented for the first time in this device class, with the lowest possible power consumption.
Wide Range of Functions
2 digital inputs are provided, as well as an analog input plus a second current output for another measured value.

Zone 1 Explosion Protection
Stratos Pro is designed for operation in Zone 1 / Class 1 Division 1 hazardous areas (with the sensor in Zone 0). Operation in hazardous areas from –20 °C to +65 °C is possible. The devices are designed for gas and dust explosion protection (G/D) and can naturally also be used outdoors (type 4 enclosure, UV resistant).

Nous attendons avec impatience votre réponse!
Nous Contacter

Détails techniques

2 ou 4 fils: 2 fils
Boîtier: Molded enclosure, PBT/PC, glass-reinforced
Canaux: 1 canal
Communication (Sortie numérique): HART
Gamme de produits: Stratos, Stratos Pro
Paramètres de mesure: oxygène
Protection contre les explosions: Ex
Raccordement de la sonde: Analogue
Sorties de courant: 2x 4 … 20 mA
permanently installed / portable: permanently installed
Écran: Écran graphique couleur TFT 4,3", rétro-éclairé blanc

Téléchargements

Manuals

[13591] Transmitter Specific HART Command Specification
Stratos Pro A201 Oxy / A401 Oxy
Device Revision: 2
[13596] Transmitter Specific HART Command Specification
Stratos Evo A402 Oxy / Device Type 0xD4 Device Revision: 5
Stratos Pro A201 Oxy / Device Type 0xE6 Device Revision: 3
[3947] Manuel utilisateur
Stratos Pro A2... OXY
Mesure de l’oxygène
Version 04

Brochures

[14695] Brochure
Stratos Pro
2-wire analyzers for pH/ORP, conductivity or oxygen

Fiches techniques

[16180] Data sheet (EN)
Stratos Pro A201
Product Description | Specifications | Product Range

Certificats

[8040] Certificate of Conformity (FM-Canada)
No. FM21CA0052 (Canada) | 2021-11-01
Stratos Pro Types A201X…, A211X…, A201B…, A221X… and A231X… | Stratos Multi Type E401X
[12932] EU Declaration of Conformity
No. EU210721B | 2021-07-21
for Stratos Pro Type A201X…
[17027] EU Type-Examination Certificate
No. KEMA 08ATEX0100 | 2024-03-07
Issue No. 10
Stratos Pro Types A201X…, A201X-*-0-T6, A211X…, A221X… and A231X… | Stratos Multi Type E401X
[17021] IECEx Certificate of Conformity
No. IECEX KEM 08.0020
Issue No. 9 | 2024-03-07
Stratos Pro Types A201X…, A201X-*-0-T6, A211X…, A201B…, A221X…, A231X | Stratos Multi Type E401X
[16316] Certitficate of Conformity (China - Ex NEPSI)
Cert No. GYJ20.1052X | 2020-06-10
Stratos Pro A20..X / Multi E401X
[12917] Quality Control Certificate
Device Settings for Customer-Specific Buffer Solutions
Version 01

Installation guides

[16777] Instructions d'installation
MK-OXY045/046…
Mesure de l’oxygène pour la gamme d‘appareils Stratos
Version 02

Safety guides

[7598] Safety Guide
Stratos Pro / MS / Evo Series
Installation and Use in Hazardous Locations
Version 05

Schémas de Contrôle

[13038] Control Drawing
Stratos Pro Type A20.X…
Zeichnungsnummer 212.002-100 page 3 rev.7
INMETRO
[13043] Control Drawing
Stratos Pro Type A201X-*-0-T6
Zeichnungsnummer 212.002-100 page 5 rev.4
ATEX, IECEx

Software

[17222] EDD (AMS)
Stratos Pro A201 Oxy
Device Revision 04 (02)
[13586] EDD (AMS)
Stratos Pro A201 Oxy
Device Revision 03
[13580] EDD (PDM)
Stratos Pro A201 Oxy
Device Revision 03
[17228] EDD (PDM)
Stratos Pro A201 Oxy
Device Revision 04 (02)
[12189] EDD (AMS)
Stratos Pro A201 Oxy
Device Revision 02
[12196] EDD (PDM)
Stratos Pro A201 Oxy
Device Revision 02
[17234] DTM (Pactware)
Stratos Pro A201 Oxy
Device Revision 04
[13575] DTM (Pactware)
Stratos Pro A201 Oxy
Device Revision 03
[12186] DTM (Pactware)
Stratos Pro A201 Oxy
Device Revision 02
[16168] GSD
Stratos Pro A221 Multi (PA)
Device Revision 01
[18054] Software
KnUT (Knick Update Tool)

Notre service

Utilisé dans les processus ou les applications

Les tours de refroidissement sont utilisées dans de multiples secteurs industriels pour évacuer la chaleur industrielle des circuits de refroidissement. Les dépôts minéraux et la corrosion diminuent l’efficacité et conduisent à l’usure prématurée des composants des installations.

Produits apparentés

Articles de blog pertinents

Sturdy 2-Electrodes Conductivity Sensor SE625 with Coaxial Electrodes made of Titanium

The SE625 ensures reliable and accurate determination of the conductivity of ultrapure water in the semiconductor industry.

Combined pH- and ORP-Sensor SE555X/*-AMSN

Combined pH and ORP measurement in one sensor SE555 saves place and equipment costs for demanding requirements in the chemical industry, the food sector and for hygienic applications.

SE655X numérique et SE656X numérique – Sondes de conductivité numériques avec certification Ex

SE655X numérique et SE656X numérique avec rapport Memosens sont disponibles avec une certification Ex. Elles sont particulièrement adaptées à l’industrie chimique, du papier et de la cellulose ainsi qu'à la surveillance des eaux usées industrielles.

Nouvelle sonde de conductivité numérique SE656N

New toroidal Digital Conductivity Sensor with a large measuring range and consisting of PFA for using in aggressive media

How to get the sensor into the process

Sensors as the direct interface to the process must be exactly matched to the chemistry of the measured medium and to the prevailing pressure and temperature conditions.