Passer au contenu principal

Stratos Pro A221N Multiparameter Transmitter | Memosens/Analog Sensors | Profibus

Description

Stratos Pro A221N Multiparameter Transmitter | Memosens/Analog Sensors | Profibus

2-wire analyzer (PROFIBUS DP/PA)

  • Intuitive operation with color-coded user guidance
  • IP 66/67, NEMA 4X protection
  • Automatic sensor identification
  • Sensor diagnostic with wear indication, remaining lifetime, CIP/SIP counter and adaptive calibration timer
  • High-contrast widescreen display with colored backlighting
  • Protective pane made of safety glass
  • One analog input (4 ... 20 mA) e.g. for external pressure compensation
  • Two parameter sets
  • Two digital inputs: 
    • External HOLD activation
    • External switching between parameter set
  • Logbook (200 entries)
Outstanding properties
A number of outstanding technological properties make the Stratos Pro series the new benchmark for 2-wire analyzers. Colored screen backlighting has been implemented for the first time in this device class, with the lowest possible power consumption.
 
Wide Range of Functions
2 digital inputs are provided, as well as an analog input plus a second current output for another measured value. 

Nous attendons avec impatience votre réponse!
Nous Contacter

Détails techniques

2 ou 4 fils: 2 fils
Boîtier: Molded enclosure, PBT/PC, glass-reinforced
Canaux: 1 canal
Communication (Sortie numérique): PROFIBUS
Gamme de produits: Stratos, Stratos Pro
Paramètres de mesure: pH, pH/potentiel redox, multiparamètres, oxygène, potentiel redox, conductivité (conductive)
Protection contre les explosions: pas d'Ex
Raccordement de la sonde: Memosens | Analogue
Sorties de courant: pas de sortie mA
permanently installed / portable: permanently installed
Écran: Écran graphique couleur TFT 4,3", rétro-éclairé blanc

Téléchargements

Manuals

[12606] User Manual
PROFIBUS DP/PA
Stratos Evo A451N | Stratos Pro A221 (N/X)
Version 02

Brochures

[14695] Brochure
Stratos Pro
2-wire analyzers for pH/ORP, conductivity or oxygen

Fiches techniques

[16180] Data sheet (EN)
Stratos Pro A201
Product Description | Specifications | Product Range

Certificats

[12917] Quality Control Certificate
Device Settings for Customer-Specific Buffer Solutions
Version 01

Safety guides

[7598] Safety Guide
Stratos Pro / MS / Evo Series
Installation and Use in Hazardous Locations
Version 05

Software

[13606] EDD (PDM)
Stratos Profibus PA A221 Multi
Device Revision 01
[13601] DTM (Pactware)
Stratos Profibus PA A221 Multi
Device Revision 01
[16168] GSD
Stratos Pro A221 Multi (PA)
Device Revision 01
[17577] SOFTWARE
FDI
Stratos Profibus PA A221 Multi
Device Revision 01
[18054] Software
KnUT (Knick Update Tool)

Notre service

Utilisé dans les processus ou les applications

Les tours de refroidissement sont utilisées dans de multiples secteurs industriels pour évacuer la chaleur industrielle des circuits de refroidissement. Les dépôts minéraux et la corrosion diminuent l’efficacité et conduisent à l’usure prématurée des composants des installations.

Produits apparentés

Articles de blog pertinents

Sturdy 2-Electrodes Conductivity Sensor SE625 with Coaxial Electrodes made of Titanium

The SE625 ensures reliable and accurate determination of the conductivity of ultrapure water in the semiconductor industry.

Combined pH- and ORP-Sensor SE555X/*-AMSN

Combined pH and ORP measurement in one sensor SE555 saves place and equipment costs for demanding requirements in the chemical industry, the food sector and for hygienic applications.

SE655X numérique et SE656X numérique – Sondes de conductivité numériques avec certification Ex

SE655X numérique et SE656X numérique avec rapport Memosens sont disponibles avec une certification Ex. Elles sont particulièrement adaptées à l’industrie chimique, du papier et de la cellulose ainsi qu'à la surveillance des eaux usées industrielles.

Nouvelle sonde de conductivité numérique SE656N

New toroidal Digital Conductivity Sensor with a large measuring range and consisting of PFA for using in aggressive media

How to get the sensor into the process

Sensors as the direct interface to the process must be exactly matched to the chemistry of the measured medium and to the prevailing pressure and temperature conditions.