Product added to compare
Product Compare added Product Compare

P16000 Pulse Frequency Conditioner | Input speed sensor signal up to 20kHz | Safe decoupling acc. SIL3

Description

P16000 Pulse Frequency Conditioner | Input speed sensor signal up to 20kHz | Safe decoupling acc. SIL3

The ProLine P 16000 receives signals from speed sensors and transmits and converts them into electrically isolated analog standard signals.

  • Pulse frequency measurement, e.g., of speed sensors / rotary encoders for safe detection of the train’s speed or standstill; galvanic isolation and
  • conversion into standard signals; measuring ranges: 0 ... 500 Hz to 0 ... 20 kHz.
  • Converting the pulse frequency into a standard signal eliminates the need for pulse counting inputs at the control unit.
  • Safety-related signals from existing circuits can be duplicated without interaction and can be transmitted to another subsystem.
  • The absence of interaction is designed to be functionally safe and achieves SIL 3.
  • 5-year warranty

The input is designed in a way that it can “tap” signals from existing circuits without disturbing the original signal. This absence of interaction complies with the SIL 3 integrity level according to EN 61508. 

Even a safety-oriented signal from a sensor can be duplicated and transmitted to a second controller without any interaction.

The product is resistant against the harsh environmental conditions typical of rolling stock applications. The device functionality is not affected by electromagnetic interferences, extreme ambient temperatures or vibration and shock. The latest fire safety regulations for rail vehicles are met.

Standards

  • Use on rolling stock – EN 50155
  • Power supply – EN 50155 (S2), RIA12/1984)
  • Fire protection (HL3) – EN 45545-2
  • Functional safety – EN 61508
  • Reliability (MTBF) – EN 61709
  • Protection against electric shock – EN 61140
  • Vibration / Shock (Category 1, Class B) – EN 61373 (IEC 61373)
  • EMC—railway applications – EN 50121-1, EN 50121-3-2
  • EMC—industrial applications – EN 61326-1
  • Temperature class TX (-40…+85 °C) – EN 50155 / EN 50125-1 and EN 50125-2
  • Altitude class AX (2000 m or 4000 m AMSL) – EN 50155 / EN 50125-1 and EN 50125-2
  • Insulation coordination for railway and industry -EN 50124-1, EN 61010-1
  • Electrical safety and fire protection USA – UL 61010-1

Nous attendons avec impatience votre réponse!
Nous Contacter

Détails techniques

Alimentation électrique: 24 V CC, Autres, Sans
Catégorie de produits: Convertisseur de mesure, Multiplicateur de signal
Type d'appareil: Convertisseur de fréquence
Entrée: Entrée de fréquence
Sortie: 0 … 20 mA, 4 … 20 mA, ±10 V
Tension de service min.: 50 V, 300 V
Classe d'erreur: < 0,5 %
Boîtier: Boîtier série 12,5 mm

Téléchargements

Brochures

[18000] Brochure
Precision Devices for the Rail Industry

Notre service

Lorem lorem ipsum ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet. Lorem ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet.

Utilisé dans les processus ou les applications

Amplificateurs séparateurs haute tension et convertisseurs de mesure pour l’acquisition et la conversion de signaux de courant, de tension, de température, de régime, de dilatation et de résistance.
Amplificateurs séparateurs haute tension stables à long terme, convertisseurs de mesure et multiplicateurs de signaux pour les applications exigeantes

Produits apparentés

Articles de blog pertinents

Knick Austria - direct customer contact in Austria from 2024

Reorganization of sales in Austria and new contacts in the field of process analytics and interface technology

InnoTrans 2022 - three products as world firsts for rolling stock and DC traction power supply applications

At InnoTrans 2022 Knick presented 3 products as world firsts for rolling stock and DC traction power supply applications.

Energy storage - the handshake between renewable energy and electric vehicles

Energy storage technology such as battery and hydrogen are critical for growth and continuous development of renewable energy and e-mobility.

Le détecteur de tension P52000VPD assure une détection fiable des tensions jusqu'à 4200 V DC

Le nouveau détecteur de tension P52000VPD (Voltage Presence Detection) assure une surveillance fiable des zones à haute tension et envoie un signal à la commande de l'installation en aval lorsqu'une valeur seuil définie est atteinte.

Knick Interface at Battery and Electric & Hybrid Vehicle Technology Expo

Knick will be showcasing high-voltage electrical measurement and signal conversion products.

VariTrans A20340 - Multiplication des signaux normalisés dans un seul amplificateur séparateur

The A20340 can output a standard input signal to four calibrated and galvanically isolated outputs in parallel.

Electrical measurement and process analytics for hydrogen production

Knick products optimize hydrogen production in the process and in electrolyser operation.

Condition Monitoring of High-Voltage Motors

Having an active predictive maintenance campaign in place for large rotating equipment can be a key strategy for maximizing process uptime.

Convertisseur de fréquence pour capteurs de vitesse

The new P16000 from Knick is a pulse frequency conditioner that converts frequency signals from speed sensors into standard signals.

Le convertisseur le plus compact du monde jusqu’à ±2200 V

La série VariTrans P 40000 de Knick permet de réaliser des mesures de tension fiables de ±50 mV jusqu’à ±3600 V et des mesures de courant de ±100 mA jusqu’à ±20 kA. Cette série ProLine éprouvée accueille à présent le convertisseur P42000D2.

L’importance des systèmes d’alimentation à large spectre pour les mesures électriques DC

De nombreux instruments de mesure électrique DC fabriqués par Knick comprennent une alimentation universelle, ou à large spectre. Cela signifie qu’ils fonctionnent avec un spectre relativement large de tension, par exemple 20…253 V, AC ou DC.

Mesure de la dégradation photovoltaïque

L’ampleur de la dégradation photovoltaïque (PV) est un élément important à prendre en compte pour la conception et l’installation de systèmes. Des facteurs tels que la météo et l’exposition aux UV contribuent au déclin de la performance.

Solutions de mesures électriques : Contrôles de 480 à 4800 Volts

Les transducteurs de tension de Knick permettent un contrôle réel aux applications de mesures électriques dans un vaste éventail de secteurs.

Les avantages des transducteurs haute tension par rapport aux transformateurs de mesure

Les transformateurs ont longtemps été considérés comme des composants importants des systèmes électriques. Il ne fait aucun doute que ces appareils sont essentiels.

Shunt Resistor versus Hall Effect Technology

There are many systems where measurement of large DC currents are needed for performance and safety.

MTBF beyond 3000 years: A snap hook for your plant

Failure of equipment on the plant floor can lead to considerable and costly disruption.

Knick Products Comply With UL - What Does That Mean?

There are different assessments and approaches to reach an adequate level of safety. Manufacturers are typically on the “safe” side, if they comply with recognized standards.

High-voltage transducer offers more safety on railway vehicles

The requirements placed on railway vehicles have increased significantly in recent years. Products for rolling stock need to ensure a higher level of functional safety than ever before.

True RMS Measurement with P41000TRMS

Traditional millivolt AC transducers are very susceptible to errors due to their poor insulation and are only designed for pure sinewave measurement.

Functional safety and maximum availability can go together

The requirements on operational and safety-related circuits are continuously growing.