The universal P32300 resistance transmitters provide connection possibilities for all standard potentiometers for angle, path or position detection up to 50 kohms. They can be flexibly adapted to the respective measuring task using DIP and rotary encoder switches or via an IrDA port.

  • Universal usability
    with potentiometers, resistive sensors, remote resistance transducers, and similar sensors
  • Convenient setting
    of all parameters via IrDA port. Uncomplicated, menu-guided adjustment also “on site” including archiving of the configuration data
  • Intuitive configuration
    of basic parameters. Easy, without tools, using 4 rotary and 8 DIP switches
  • Calibrated range selection
    No complicated trimming
  • Convenient adjustment
    Zero point and sensitivity adjustable via IrDA port. Simulation of any desired output values for correct installation/commissioning
  • Protective separation
    according to EN 61140 – protection of the maintenance staff and subsequent devices against excessively high voltages up to 300 V AC/DC
  • Functional safety
    up to SIL 2 (up to SIL 3 in case of redundant configuration) with TÜV certificate Systematically developed according to EN 61508
  • High accuracy
    due to innovative circuit design
  • Minimum space consumption
    in the enclosure. Only 6 mm wide modular housing. More transmitters per meter of mounting rail
  • Low-cost assembly
    Quick mounting, convenient connection of the power supply through DIN rail bus connectors (in case of 24 V DC power supply)
  • 5-year warranty

3-port isolation with protective separation up to 300 V AC/DC according to EN 61140 ensures optimal protection of personnel and equipment as well as unaltered transmission of the measurement signals.

The P32300 offer maximum performance in the smallest of spaces. Adjusting the start and end value to the individual position sensor is particularly convenient via the infrared interface, for example using a PDA. Sensors with known characteristics can be very easily calibrated using 4 rotary encoder switches and 8 DIP switches.

Special measuring tasks can be solved with SensoTrans devices that Knick configures according to individual specifications. Fixed-range devices without switches are used, for example, when manipulations or mix-ups must be precluded.

Knick offers the P32300 transmitter with SIL approval for applications with high demands on functional safety. The requirements of EN 61508 were implemented through specially developed hardware and software. The implemented fail-safe concept makes use of structural measures at the device level (redundancy of system components) and diagnostic methods for selective fault detection. The product is SIL 2 approved (EN 61508) by an authorized body (TÜV Rheinland). SIL 3 in redundant implementations.

Nous attendons avec impatience votre réponse!
Nous Contacter

Détails techniques

Alimentation électrique: 24 V CC
Catégorie de produits: Convertisseur de mesure
Homologations: CSA, SIL, UL
Type d'appareil: Convertisseur de résistance
Entrée: Résistances / Potentiomètres
Sortie: 0 … 10 V, 0 … 20 mA, 4 … 20 mA
Tension de service min.: 50 V, 300 V
Classe d'erreur: 0,1 %, < 0,5 %
Boîtier: Boîtier série 6 mm

Téléchargements

Manuals

[1500] User Manual (DE, EN, FR)
P32300 P0/ ...
Version 03
[13390] User Manual (DE, EN, FR, ES)
ZU 0677 (Power terminal block)
Version 03
[1492] User Manual (DE, EN, FR)
P32300P0/11-KTA
Version 04

Fiches techniques

[1484] Fiche technique
P32300
Description du produit | Caractéristiques techniques | Gamme de produits

Certificats

[11418] Certificate of Compliance (UL)
No. 20181015-E220033 | 2018-OCTOBER-15
POWER CIRCUIT AND MOTOR-MOUNTED APPARATUS
P32*00P0/**, A202*0P0..., BL520
[13789] EU Declaration of Conformity (DE, EN, FR)
No. EU220125H | 2022-01-25
[11665] TÜV Rheinland Certificate
No. 968/EZ 272.00/07 | 2007-10-12
Transmitter Series P32*** P0/1
EN 61508 |SlL2, SIL3
[11256] CB Test Certificate
No. DE 2-036775 | 2022-10-11
P32000, P32100, P32200, P32300, A20210, A20220, A20230

Safety guides

[1383] Guide de sécurité SIL
P32*00P0/1
Version 02

Notre service

Lorem lorem ipsum ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet. Lorem ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet.

Utilisé dans les processus ou les applications

Amplificateurs séparateurs haute tension et convertisseurs de mesure pour l’acquisition et la conversion de signaux de courant, de tension, de température, de régime, de dilatation et de résistance.
Amplificateurs séparateurs haute tension stables à long terme, convertisseurs de mesure et multiplicateurs de signaux pour les applications exigeantes

Produits apparentés

Articles de blog pertinents

Knick Products Comply With UL - What Does That Mean?

There are different assessments and approaches to reach an adequate level of safety. Manufacturers are typically on the “safe” side, if they comply with recognized standards.