Skip to main content

A20210 Temperature Transmitter | Input Pt100/Pt1000, Thermocouple | Space-saving 6 mm Enclosure

Description

A20210 Temperature Transmitter | Input Pt100/Pt1000, Thermocouple | Space-saving 6 mm Enclosure

Standard transmitters for temperature measurement in a 6 mm housing using resistance thermometers or thermocouples.

  • Flexible use
    with common temperature sensors: Pt100, Pt1000, Ni100, type J and K thermocouples
  • Intuitive configuration
    easy, without tools, using 4 rotary and 8 DIP switches
  • Calibrated range selection
    without complicated adjustment
  • Automatic detection
    of the sensor connection (2-, 3-, or 4-wire)
  • Protective separation
    according to EN 61140 – protection of the maintenance staff and down-stream devices against excessively high voltages up to 300 V AC/DC
  • High accuracy
    with innovative switching concept
  • Minimum space requirement
    in the enclosure – only 6 mm wide modular housing – more transmit-ters per meter of mounting rail
  • Low-cost assembly
    quick mounting, convenient, connection of power supply via DIN rail bus connectors
  • 5-year warranty 

The Task
In virtually all areas of industry, temperatures are continuously measured and often used as a reference input for closed-loop control systems, monitoring systems, safety shutdown systems, or for similar critical jobs. As a rule, high demands are placed on function, accuracy, flexibility and electrical safety. Different sensors are used depending on the measuring task. They provide a raw signal which is prepared, linearized and standardized for further processing using a temperature transmitter

The Problem
The range of standardized and commercial temperature sensors is extremely broad. The large number of sensors, connection variants, individual temperature ranges, different supply voltages, and required output signals call for very flexible transmitters that can be optimally suited to the different conditions. However, the required flexibility should not come at the price of complex operation. Rather, being able to easily make adjustments on site is desirable. High performance should not result in increased susceptibility – high reliability and availability are essential.

The Solution
The flexible A20210 temperature transmitters provide connection possibilities for most of the common thermocouples and resistance thermometers. They can be flexibly adapted to the respective measuring task using DIP and rotary encoder switches. 3-port isolation with protective separation up to 300 V AC/DC according to EN 61140 ensures optimum protection of personnel and equipment as well as unaltered transmission of measuring signals. The A20210 offer maximum performance in the smallest of spaces. Resistance thermometers can be operated in 2-, 3- or 4-wire configuration. The connection configuration is automatically recognized, adjustment is not required. Thermocouples can be detected with internal or external reference junction compensation. Input voltage signals up to ±1000 mV are converted into standard 0/4 to 20 mA or 0 to 10 V signals. This enables low-cost implementation of current measurements using shunt resistors, for example. Special measuring tasks can be solved with ThermoTrans devices which Knick configures according to individual specifications. Fixed-range devices without switch are used, for example, when manipulations or mix-ups must be precluded.  

We look forward to hearing from you!
Contact Us

Technical details

Function: Temperature measurement
Input: Resistance thermometers, Resistors, Shunt voltages up to ±1000 mV, Thermocouples
Output: 0 ... (±)5 V, 0 ... 10 V, 0 ... 20 mA, 4 ... 20 mA
Isolation AC/DC: up to 300 V
Test Voltage: 2.5 kV AC
Power Supply: 24 V DC
Ambient operating temperature: 0 … 55 (65) °C
Dimensions (W x L x H): 6.2 x 93 x 101 mm
Special features: For safety circuits up to SIL 3, Interface for configuration via PC, Rotary and DIP switches for easy, intuitive configuration, Transmitter for platinum temperature sensors and thermocouples or for measuring mV shunt voltages, in a 6 mm housing
Product Category: Sensor Transmitter

Downloads

Manuals

[239] User Manual (DE, EN, FR, BR)
A20210P0/…
Version 03
[13390] User Manual (DE, EN, FR, ES)
ZU 0677 (Power terminal block)
Version 03

Brochures

[14160] Brochure
Product Overview Interface Technology

Data Sheets

[229] Data sheet
A20210
Product Description | Specifications | Product Range

Certificates

[11256] CB Test Certificate
No. DE 2-036775 | 2022-10-11
P32000, P32100, P32200, P32300, A20210, A20220, A20230
[11418] Certificate of Compliance (UL)
No. 20181015-E220033 | 2018-OCTOBER-15
POWER CIRCUIT AND MOTOR-MOUNTED APPARATUS
P32*00P0/**, A202*0P0..., BL520
[13789] EU Declaration of Conformity (DE, EN, FR)
A20210P0, P32100P0, A20220P0, P32200P0, A20230P0, P32300P0, P32000P0
No. EU231123A | 2023-11-23

Software

[12154] Software (.zip)
ePLAN P8 Produktmakros
[11876] Knick Produktmakros (.pdf)
ePLAN Electric P8

Our service

Used in Process or Applications

High voltage transducers and signal conditioners for the acquisition and conversion of current, voltage, temperature, speed, strain and resistance signals.

Related Products

Relevant Blog Posts

Stack and String Voltage Measurement in Electrolyzers and Fuel Cells

Voltage, current and temperature measurement in electrolyzers with P40000 series high voltage transducers

New 30 mV Shunt Resistors for Knick Transducers

Knick is expanding the accessory range for its high-voltage transducers with immediate effect by adding shunt resistors with a 30 mV voltage drop
Innovations at InnoTrans 2024

Innovations at InnoTrans 2024 for rolling stock and DC traction power supply

At InnoTrans 2024 Knick presents electrical measurement solutions for rolling stock and DC traction power supply applications

Knick Austria - direct customer contact in Austria from 2024

Reorganization of sales in Austria and new contacts in the field of process analytics and interface technology

Energy storage - the handshake between renewable energy and electric vehicles

Energy storage technology such as battery and hydrogen are critical for growth and continuous development of renewable energy and e-mobility.

P52000VPD voltage presence detector reliably detects voltages up to 4200 V DC

The new P52000VPD voltage presence detector reliably monitors areas with high voltages and sends a signal to the downstream plant control system when a specified threshold value is reached.

Knick Interface at Battery and Electric & Hybrid Vehicle Technology Expo

Knick will be showcasing high-voltage electrical measurement and signal conversion products.

Quadruple Standard Signals in Just One Signal Conditioner

The A20340 can output a standard input signal to four calibrated and galvanically isolated outputs in parallel.

Electrical measurement and process analytics for hydrogen production

Knick products optimize hydrogen production in the process and in electrolyser operation.

Condition Monitoring of High-Voltage Motors

Having an active predictive maintenance campaign in place for large rotating equipment can be a key strategy for maximizing process uptime.

Pulse frequency conditioner for speed sensors

The new P16000 from Knick is a pulse frequency conditioner that converts frequency signals from speed sensors into standard signals.

Worldwide smallest transducer up to ±2200 V

The P40000 series from Knick enables reliable voltage measurements from ±50 mV to ±3600 V and current measurements from ±100 mA to ±20 kA.

Importance of broad-range power supplies for DC electrical measurement

Many DC electrical measurement products manufactured by Knick contain universal, also known as broad-range, power supplies.

Measuring Photovoltaic Degradation

Photovoltaic (PV) array degradation is an important aspect to consider for system design and installation.

Electrical Measurement Solutions: Control from 480 to 4800 Volts

Voltage and current transducers from Knick bring true control to electrical measurement applications across a wide-range of industries.

Benefits of High Voltage Transducers versus Instrument Transformers

When a need arises to step voltage in a circuit either up or down for purposes of power transmission or distribution, there is no doubt that transformers are essential.

Shunt Resistor versus Hall Effect Technology

There are many systems where measurement of large DC currents are needed for performance and safety.

MTBF beyond 3000 years: A snap hook for your plant

Failure of equipment on the plant floor can lead to considerable and costly disruption.

Knick Products Comply With UL - What Does That Mean?

There are different assessments and approaches to reach an adequate level of safety. Manufacturers are typically on the “safe” side, if they comply with recognized standards.

High-voltage transducer offers more safety on railway vehicles

The requirements placed on railway vehicles have increased significantly in recent years. Products for rolling stock need to ensure a higher level of functional safety than ever before.

True RMS Measurement with P41000TRMS

Traditional millivolt AC transducers are very susceptible to errors due to their poor insulation and are only designed for pure sinewave measurement.

Functional safety and maximum availability can go together

The requirements on operational and safety-related circuits are continuously growing.
>