P27000 Universal Isolated Signal Conditioner | Calibrated switching of 480 input and output ranges | Isolation up to 1000 V

The “Multimeter” among the signal conditioners. With 480 switchable calibrated ranges and broad-range power supply.

  • Flexible and extremely precise
    Calibrated range selection without complicated readjustments
  • Broad-range power supply
    VariPower 20 … 253 V AC/DC
  • Compact design
    12.5 mm modular housing; up to 80 active isolators per meter of mounting rail
  • Quick and easy configuration
    Housing can be easily opened
  • Pluggable screw terminals
    Simple, time-saving assembly and prewiring of enclosures
  • 3-port separation
    Protection against incorrect measurements or damage
  • Maximum accuracy
  • Specific test report
    Following EN 10204 2.2
  • Protective separation
    According to EN 61140. Protection against unacceptably high voltages (for example, with shunt measurements at high potentials or in 3-phase systems)
  • Maximum reliability 
    No repair and failure costs
  • 5-year warranty

The isolation amplifiers provide safe galvanic isolation for any input signals from ±20 mV to ±200 V and from ±0.1 mA to ±100 mA.

여러분의 의견을 기다리겠습니다!
문의하기

기술 세부 정보

전위 차단 AC/DC: 최대 1,000 V
기능: 전류 및 전압 측정
입력: 0 ... (±)0.1 mA 최대 0 ... (±)100 mA, 0 ... (±)10 V, 0 ... (±)20 mA, 0 ... (±)20 mV 최대 0 ... (±)200 V, 4 ... 20 mA
출력: 0 ... (±)10 V, 0 ... (±)20 mA, 4 ... 20 mA
최소 시험 전압: 5 kV AC
전원 공급장치: 22 ... 230 V AC/DC
차단 주파수: 전환 가능한 차단 주파수10 kHz 또는 10 Hz, 요청 시 다른 차단 주파수 제공
작동 환경 온도: –10 ... 70 °C
치수(W x L x H): 12.5 x 99 x 111 mm
특장점: DIP 스위치를 통한 480개의 입력및 출력 범위의 교정된 전환, 절연 증폭기 아래의 "멀티미터"
제품 카테고리: 범용 아이솔레이터 / 표준 신호 아이솔레이터

다운로드

사용 설명서 (매뉴얼)

[1302] User Manual (DE, EN, FR)
P27000
Version 06
[10953] User Manual (DE, EN)
P27000-S008
Version 04
[10880] User Manual (DE, EN)
P27000-S009
Version 04
[10940] User Manual (DE, EN)
P27000-S0011
Version 01

데이터 시트

[1291] 데이터 시트
P27000
제품 설명 | 명세서 | 제품 범위

인증서

[12124] EU Declaration of Conformity (DE, EN, FR)
P27***H1…, P27***F1…
No. EU240613A | 2024-06-13
[14100] Quality Report (MTBF)
Document No. TX180228A
Failure Rate
[11577] Type Approval Certificate (DNV)
P270X Y1
No: TAA000011Y
Revision No: 3
[11827] Certificate of Compliance (UL)
Series P27000 through P27099...
Process Control Equipment for Use in Hazardous Locations
No. E308146 | 2018-10-29
[11771] Certificate of Compliance (UL)
Series P 27000 through P 27099...
Process Control Equipment for Use in Zone Classified Hazardous Locations
No. E3402288 | 2018-10-15
[11779] Certificate of Compliance (UL)
Series P 270**BL570
Process Control Equipment, Electrical
No. E340287 | 2019-11-22

Software

[12153] Software
VariSoft SW 108 Configuration Software
[11875] Knick Produktmakros
ePLAN P4 (.pdf)
[12144] Software
ePLAN P4 Produktmakros
[11876] Knick Produktmakros (.pdf)
ePLAN Electric P8
[12154] Software (.zip)
ePLAN P8 Produktmakros

서비스

프로세스 또는 애플리케이션에서 사용

전류, 전압, 온도, 회전 속도, 변형 및 저항 신호의 측정과 변환을 위한 고전압 절연 증폭기 및 트랜스미터.
까다로운 분야에서의 사용을 위한 장기적으로 안정적인 고전압 절연 증폭기, 트랜스미터 및 신호 배율기

관련 제품

관련 블로그 게시물

Sturdy 2-Electrodes Conductivity Sensor SE625 with Coaxial Electrodes made of Titanium

The SE625 ensures reliable and accurate determination of the conductivity of ultrapure water in the semiconductor industry.

Combined pH- and ORP-Sensor SE555X/*-AMSN

Combined pH and ORP measurement in one sensor SE555 saves place and equipment costs for demanding requirements in the chemical industry, the food sector and for hygienic applications.

SE655X 디지털 및 SE656X 디지털 - 방폭 인증을 받은 디지털 전도도 센서

Memosens 프로토콜을 채택한 전도도 센서 SE655X 디지털 및 SE656X 디지털은 이제 방폭 인증을 받은 제품으로 사용할 수 있습니다. 이 센서들은 재질과 설계로 인해 특히 화학, 제지 및 펄프 산업과 산업 폐수 모니터링에 적합합니다.

새 디지털 전도도 센서 SE656N

New toroidal Digital Conductivity Sensor with a large measuring range and consisting of PFA for using in aggressive media

How to get the sensor into the process

Sensors as the direct interface to the process must be exactly matched to the chemistry of the measured medium and to the prevailing pressure and temperature conditions.