Description
High Voltage transducer for current measurement with shunt resistor in systems up to 4800 V
- Overload-protected current measurement via shunt resistor from amps to kiloamps with up to 10 switchable calibrated ranges
- Short circuit recognition
- Monitoring and control of traction motors and converters
- Rated isolation voltage up to 4800 V AC/DC
- Housing offers protection against contact and pollution for added safety
- Circuit monitoring with self-diagnostics
- Selectable input ranges and floating standard signal outputs for flexible, easy system integration
- Integrated broad-range power supply
- Resistant in tough conditions: extreme temperatures, shock, vibration and harsh EMC environments
Maximum flexibility is achieved through a new housing concept — specifically designed for rolling stock. With integrated broadrange power supply and a unique combination of safety functions.
Electric as well as diesel-electric locomotives and multiple units (EMU/DEMU) require multifold monitoring and control of electric energy. Voltage and current sensors used for this purpose need to meet the special demands posed by railway operations.
Of particular concern are fire and smoke protection, electrical safety, as well as robustness towards extreme environmental conditions, mechanical stress and EMI influences.
The P50000 transducer series was specifically designed for applications on locomotives and multiple units for short circuit recognition, monitoring and control of traction motors and converters, auxiliary converters, accumulator batteries and others. A brand new feature is the flexibility provided by switchable measuring ranges and an integrated broad-range power supply.
Comprehensive certifications and conformity with railway standards make the devices the ideal choice for railway applications.
여러분의 의견을 기다리겠습니다!
문의하기
전위 차단 AC/DC: | 최대 4,800 V |
---|---|
입력: | 0 ... (±)30 mV 최대 0 ... (±)100 V |
출력: | 0 ... (±)5 V, 0 ... (±)10 V, 0 ... (±)20 mA, 4 ... 20 mA |
최소 시험 전압: | 12/18 kV AC |
전원 공급장치: | 24 ... 230 V AC/DC |
차단 주파수: | 전환 가능한 차단 주파수 14 kHz(P51x00) 및 10 Hz, 요청 시 다른 차단 주파수 제공 |
작동 환경 온도: | –40 ... 85 °C |
치수(W x L x H): | 72.5 x 182 x 116 mm |
특장점: | 기차 차량 내 에너지 측정용 (EN 50463) 고정확도 버전 제공, 입력 회로/출력 회로의 진단 및장치 기능, 철도 차량에서 사용하기 위한 용도(EN 50155) |
표준: | EN 45545-2, EN 50121, EN 50155:2021, EN 50463, EN 61373, UL 347 |
제품 카테고리: | 고전압 절연 증폭기 |