Product added to compare
Product Compare added Product Compare

P52000 VPD High Voltage Transducer | Input max. 4200 V DC or AC peak | Voltage presence detection

Description

P52000 VPD High Voltage Transducer | Input max. 4200 V DC or AC peak | Voltage presence detection

Railway and Industrial Application Solution for Monitoring Voltages from 50 - 4200 V AC/DC

Standard/Directive | Industry Standards

  • EN 50155, RIA12/1984
    Broad-range power supply 24 ... 230 V DC/AC, stable during brownouts – Class S2
  • EN 45545-2a)
    Fire protection (HL 3) 
  • EN 50155
    Use on rolling stock 
  • EN 50155, EN 50125-1, EN EN 50125-2
    Temperature class TX (-40 ... +85 °C) and altitude class AX (2000 m or 4000 m AMSL)
  • EN 50123-1
    Use in traction power substations
  • EN 61709
    Reliability
  • EN 61140
    Protection against electric shock
  • EN 61373
    Resistant to vibration and mechanical shock (railway applications)
  • EN 50121-1, EN 50121-3-2; EN 61326-1
    EMC for railway applications and industrial applications
  • EN 50153
    Protective measures against electrical hazards (contact protection through protective covers; housing IP protection: IP54 high-voltage side, IP33 low-voltage side)
  • EN 50124-1, EN 50123-1, EN 50178
    Isolation coordination for railway and industry

P52000 VPD detects the presence of voltage. The input signal is compared to a threshold value and the resulting binary information is galvanically isolated and transmitted to the output circuit. When the input voltage exceeds the set threshold value, a solid state relay opens, signaling the presence of voltage at the input.

The signal of the solid state relay can control a hardware relay, for example, or be fed into a safety device or controller. The signal levels are based on type 1, EN 61131-2 PLC signal inputs.

The threshold value applies regardless of the sign of the input voltage’s absolute value. In other words, the solid state relay will be triggered as soon as the positive threshold value is exceeded or the input voltage is below the negative threshold.

10 default threshold values can be selected using the rotary switch on the front of the device. Units with user-defined values are also available.

여러분의 의견을 기다리겠습니다!
문의하기

기술 세부 정보

제품 카테고리: 고전압 절연 증폭기
구조: 표면 장착형 외함 / 나사식 플랜지

다운로드

브로셔

[18000] Brochure
Precision Devices for the Rail Industry

서비스

Lorem lorem ipsum ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet. Lorem ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet.

프로세스 또는 애플리케이션에서 사용

전류, 전압, 온도, 회전 속도, 변형 및 저항 신호의 측정과 변환을 위한 고전압 절연 증폭기 및 트랜스미터.

관련 제품

관련 블로그 게시물

전압 검출기 P52000VPD는 최대 4200 V DC까지 전압을 안정적으로 감지합니다.

새로운 전압 감지기 P52000VPD(전압 존재 감지)는 고전압 영역을 안정적으로 모니터링하고 전압이 지정된 임계값에 도달하면 신호를 다운스트림 시스템 제어 장치로 전송합니다.