메인 콘텐츠로 건너뛰기

Portavo 904X COND Portable Conductivity Transmitter | Memosens/Analog Sensors | Ex Zone 0/1 | Data Logger

Description

Portavo 904X COND Portable Conductivity Transmitter | Memosens/Analog Sensors | Ex Zone 0/1 | Data Logger

Portable, sturdy process analyzer for conductivity measurement in hazardous locations. Ideal for applications in the process industry.

  • Use in hazardous locations
  • Memosens sensors or analog sensors for conductivity measurement can be used with one device
  • Can be used with toroidal conductivity sensors with Memosens protocol
  • Sensor quiver protects the sensor from damage
  • The sturdy housing with IP66/67 protection is also suitable for outdoor use
  • Data logger with 5,000 values
  • Micro USB port and Paraly SW 112 operating software
  • Mineral glass screen can still be read perfectly after many years
  • User management for access control
  • Sensor verification for clear assignment of the sensor to the device via sensor type, TAG, or group
  • Temperature detector adjustment in the Memosens sensor (offset correction)

Portavo 904 X Cond makes it possible to check process measuring points directly on site. Memosens or analog conductivity sensors can be connected to the Portavo.

Up to 5,000 values can be recorded using the integrated data logger. The MemoLog function enables the logging of calibration data from various Memosens measuring points, which can then be easily transferred to a PC via the USB interface. The Paraly SW 112 software enables easy management of all recorded data.

Security Package, Including User Management
Professional user management regulates access to the device and the sensor.

  • Increased security for configuration, calibration, measurement data, and data logger settings.
  • No unauthorized interventions during the operating cycle
  • Up to 4 user profiles can be set
  • Different access rights can be established

Depending on the user’s experience, the role profile can optionally be defined for configuration of the device and sensor or for sensor calibration. This clearly minimizes the risk of inadvertently changing settings.

Greater Reliability During Operation
Memosens sensors can be assigned directly to the Portavo using the data stored in the sensor, such as

  • Sensor type
  • TAG
  • Group

Unambiguous assignment of the sensor to the device reduces the potential for errors. This ensures that only the right sensors are used for the selected measuring point.

여러분의 의견을 기다리겠습니다!
문의하기

기술 세부 정보

permanently installed / portable: portable
데이터 기록 장치: 5,000개의 항목이 있는 데이터 로거
디스플레이: 3줄 및 기호가 있는 LCD STN 7-세그먼트 디스플레이
부가적인 기능: 사용자 관리, 센서 제어, 온도 조절하기
외함: PA12 GF30 (silver gray RAL 7001) + TPE (black)
제품 라인: Portavo
채널: 1 채널
측정 파라미터 : 전도도
폭발 방지: Ex

다운로드

사용 설명서 (매뉴얼)

[1903] User Manual
Portavo 904(X) Cond
Version 03
[16855] ChangeLog Firmware History
Portavo 904
Document version 1.4.0
[12673] User Manual
Software Paraly SW 112
Version 05
[13862] Safety Guide
Portavo 900 Series
Version 04

브로셔

[16192] Brochure
Portavo (Overview)

데이터 시트

[1839] 데이터 시트
Portavo 904X COND
제품 설명 | 명세서 | 제품 범위
[2022] Datasheet
Overview of Portavo

인증서

[9759] EU Declaration of Conformity (DE, EN, FR)
No. EU210706A | 2021-07-06
Serie Portavo 90*X*

Software

[12703] Software
Paraly SW 112 PC Software
[18054] Software
KnUT (Knick Update Tool)

서비스

프로세스 또는 애플리케이션에서 사용

식수 처리에서는 사용한 원수의 품질 점검이 매우 중요한 의미를 갖습니다.

관련 제품

관련 블로그 게시물

Combined pH- and ORP-Sensor SE555X/*-AMSN

Combined pH and ORP measurement in one sensor SE555 saves place and equipment costs for demanding requirements in the chemical industry, the food sector and for hygienic applications.