WA131 SensoGate Retractable Fitting | Modular | Pneumatic | For simple, commercial controllers

Universal, pneumatically operated retractable fitting with a modular design for simple controllers

  • compact, smooth, and dirt-resistant design
  • minimum maintenance costs and maximum flexibility thanks to completely modular design
  • very simple replacement of gaskets due to divided calibration/cleaning chamber
  • increased service life and reduced seal wear
  • ATEX approval II 1GD c II for the complete fitting
  • cost reduction by simple installation, operation, and maintenance
  • very high availability
  • protective rinsing of the seals for a long service life
  • SensoLock for high safety of operation
  • integrated check valves and limit switches
  • fast and uncomplicated replacement of calibration chamber and immersion tube
  • all maintenance can be performed on site
  • cyclone rinsing for optimum cleaning effect
  • superior sensor immersion depth
  • standard sensor length (225 mm) even for large immersion depths
  • multiple process connections available
  • flange version with scraper ring
  • modular design allows specific replacement of the process-wetted materials: PEEK, PVDF, PP, 1.4571, Hastelloy
  • plastic versions with high pressure and temperature resistance due to carbonfiber- reinforced plastics
  • special version for sensors with pressurizable liquid electrolyte 

Variable and reasonably priced

Based on the proven SensoGate modular design principle, the WA131 retractable fitting is ideal for applications which do not require completely automated control with central media routing but which still want to make use of superior SensoGate technology.

SensoGate WA131 is ideal for automatic or semi-automatic connections to commercially available or customerdeveloped control units.

여러분의 의견을 기다리겠습니다!
문의하기

기술 세부 정보

매질 접촉부의 재질: Hastelloy, PEEK, PEEK HD, PP (polypropylene), PVDF, PVDF HD, Stainless Steel 1.4571
센서 및 어댑터: PG 13.5의 직경 12 mm의 광학식 센서, pH 센서, 가압되는 직경 12 mm의 pH 센서, 용존 산소 센서, 전도도 센서, 전도성 센서
재질 씰링: EPDM, EPDM - FDA, FFKM, FFKM - FDA, FFKM Chemraz 505, FFKM Kalrez 6375, FFKM Perlast 75B, FKM, FKM - FDA
제품 라인: SensoGate
제품 유형: 개폐식 피팅
침적 깊이: Long, ≤ 70 mm, ≤ 100 mm, ≤ 135 mm, 짧은
폭발 방지: Ex, hazardous area Zone 0
Operation: automated

다운로드

사용 설명서 (매뉴얼)

[4145] User Manual
SensoGate WA131 Retractable Fitting
Version 06
[13385] User Manual (DE, EN)
ZU 0987 (PG 13.5 Closure Plug for Sensor Lengths of 120 / 225 mm)
Version 02

데이터 시트

[4063] Overview
SensoGate Sensor Lock-Gates
Product Description | Specifications | Product Range
[4134] Data sheet
SensoGate WA131
Product Description | Specifications | Product Range

인증서

[8623] EU Type-Examination Certificate
Nr. KEMA 04ATEX4035X | 2020-03-18
Type Ceramat WA 15...-X… | WA 16...-X | WA 13…-X

Installation guides

[18025] Installation Guide
ZU1174 Adapter, Tri-Clamp 1/2 Inch
Version 01
[18026] Installation Guide
ZU1173 Adapter, Tube Diameter 6 mm
Version 01
[14205] Installation Guide (DE, EN)
ZU1045 Sensoradapter 360/SensoGate
Version 01

서비스

프로세스 또는 애플리케이션에서 사용

크닉은 혁신적인 공정 분석 기기, 고급 센서, 혁신적인 피팅과 독특한 세정 및 교정 시스템을 제공합니다.

관련 제품

관련 블로그 게시물

Stack and String Voltage Measurement in Electrolyzers and Fuel Cells

Voltage, current and temperature measurement in electrolyzers with P40000 series high voltage transducers

크닉 트랜스미터를 위한 새로운 30mV 분로 저항기

크닉은 이제 전압 강하가 30mV인 분로 저항기를 포함하도록 고전압 트랜스미터용 액세서리 제품군을 확장함
Innovations at InnoTrans 2024

Innovations at InnoTrans 2024 for rolling stock and DC traction power supply

At InnoTrans 2024 Knick presents electrical measurement solutions for rolling stock and DC traction power supply applications

Knick Austria - direct customer contact in Austria from 2024

Reorganization of sales in Austria and new contacts in the field of process analytics and interface technology

Energy storage - the handshake between renewable energy and electric vehicles

Energy storage technology such as battery and hydrogen are critical for growth and continuous development of renewable energy and e-mobility.

전압 검출기 P52000VPD는 최대 4200 V DC까지 전압을 안정적으로 감지합니다.

새로운 전압 감지기 P52000VPD(전압 존재 감지)는 고전압 영역을 안정적으로 모니터링하고 전압이 지정된 임계값에 도달하면 신호를 다운스트림 시스템 제어 장치로 전송합니다.

Knick Interface at Battery and Electric & Hybrid Vehicle Technology Expo

Knick will be showcasing high-voltage electrical measurement and signal conversion products.

VariTrans A20340 - 단 하나의 절연 증폭기에서 표준 신호 4배율

The A20340 can output a standard input signal to four calibrated and galvanically isolated outputs in parallel.

Electrical measurement and process analytics for hydrogen production

Knick products optimize hydrogen production in the process and in electrolyser operation.

Condition Monitoring of High-Voltage Motors

Having an active predictive maintenance campaign in place for large rotating equipment can be a key strategy for maximizing process uptime.

Pulse frequency conditioner for speed sensors

The new P16000 from Knick is a pulse frequency conditioner that converts frequency signals from speed sensors into standard signals.

±2200 V까지 사용할 수 있는 세계에서 가장 작은 절연 증폭기

저희 Knick의 VariTrans P 40000 시리즈를 통해 ± 50 mV에서 ± 3600 V까지의 전압과 ± 100 mA에서 ± 20 kA까지의 전류의 안정적인 측정이 가능합니다. 이미 입증된 ProLine 제품군에 DIN 레일 설치를 할 수 있도록 작은 외함을 가진 절연 증폭기 P42000D2가 추가됐습니다.

Importance of broad-range power supplies for DC electrical measurement

Many DC electrical measurement products manufactured by Knick contain universal, also known as broad-range, power supplies.

Measuring Photovoltaic Degradation

Photovoltaic (PV) array degradation is an important aspect to consider for system design and installation.

Electrical Measurement Solutions: Control from 480 to 4800 Volts

Voltage and current transducers from Knick bring true control to electrical measurement applications across a wide-range of industries.

Benefits of High Voltage Transducers versus Instrument Transformers

When a need arises to step voltage in a circuit either up or down for purposes of power transmission or distribution, there is no doubt that transformers are essential.

Shunt Resistor versus Hall Effect Technology

There are many systems where measurement of large DC currents are needed for performance and safety.

MTBF beyond 3000 years: A snap hook for your plant

Failure of equipment on the plant floor can lead to considerable and costly disruption.

Knick Products Comply With UL - What Does That Mean?

There are different assessments and approaches to reach an adequate level of safety. Manufacturers are typically on the “safe” side, if they comply with recognized standards.

High-voltage transducer offers more safety on railway vehicles

The requirements placed on railway vehicles have increased significantly in recent years. Products for rolling stock need to ensure a higher level of functional safety than ever before.

True RMS Measurement with P41000TRMS

Traditional millivolt AC transducers are very susceptible to errors due to their poor insulation and are only designed for pure sinewave measurement.

Functional safety and maximum availability can go together

The requirements on operational and safety-related circuits are continuously growing.