Product added to compare
Product Compare added Product Compare

Unical 9000 Electro-pneumatic controller | For automatic cleaning and calibration | Corrosion-proof coating

Description

Unical 9000 Electro-pneumatic controller | For automatic cleaning and calibration | Corrosion-proof coating

Maximum availability of the point of measurement: Cleaning without interrupting the process, even when measuring directly in the pressure tank

  • corrosion-proof (powder-coated stainless steel)
  • consistent enclosure concept for all devices.
  • modular design, adaptable to virtually every measuring task
  • easy assembly and retrofitting
  • tidy hose guiding
  • no entrainment and backmixing due to separate routing of the media
  • low maintenance effort due to innovative pump technology and extremely low consumption of media
  • automatic 2-point calibration
  • time-controlled cleaning and checking
  • cleaning with water and additional cleaning solution
  • reduced maintenance effort due to automatic calibration
  • no interruptions in production for calibration
  • longer sensor life due to short-time measurement and regular cleaning
  • immediate readiness for measurement after production interruption since sensor is safely stored in liquid
  • safety ensured by monitoring of the compressed air and water supply, the probe position and the buffer and cleaning solution level

In combination with the Protos process analysis system and a SensoGate or Ceramat sensor lock-gate, Unical provides the ideal functionality of a complete system for automatic process control of a pH measurement. 

It allows highly accurate measurements to be taken even with difficult process conditions such as high pressure, high temperatures, and high levels of impurities. The system can be installed next to the process, within the hazardous area.

Since the electrode is not removed for calibration, the process can continue uninterrupted. This allows problem-free measurements directly in a pressure vessel or in the main pipe. Elaborate and lockable bypasses are eliminated and accuracy increases.

Low maintenance
Fully automatic sensor calibration at user-defined intervals without interrupting the process. Two buffer solutions are automatically pumped into the calibration chamber. Only the buffer bottles need to be refilled.

Cost-effective
Low-wear and low-maintenance pumps with extremely low consumption of buffer.

Safe and easy measurement even in strongly polluted media
Sensor cleaning and rinsing is performed at user-defined intervals. Cleaning solution and water are automatically pumped into the calibration chamber. Removal and manual cleaning of the sensor are not required.

Distinction between calibration and adjustment
This allows you to check the sensor data in the running process. An adjustment is only carried out when there are preset deviations of the calibration values. Constant displacement of the measured values due to small calibration scatters is omitted.

Modern fieldbus integration
The interfaces to PROFIBUS PA or Foundation Fieldbus allow the Unical system to be integrated directly in a fieldbus network. Of course, also in hazardous areas.

Universal adaptation to retractable fittings
The modular structure of the Unical system allows any retractable fittings to be used. Optimum functionality is achieved with the Ceramat and Sensogate sensor lock-gates.

Clean and safe construction
All features for smooth, safe, and low-maintenance operation are included as standard: water pressure gage and service switch with alert message and feedback of the actual lock-gate position, air filter and water trap. Flooding sensor in the housing with alert message.

여러분의 의견을 기다리겠습니다!
문의하기

기술 세부 정보

보호 등급: IP 65/NEMA 4X
외함: Stainless steel A2, coated
측정 파라미터 : pH/ORP
치수(W x H x D): 약 320 x 400 x 120mm
폭발 방지: 전직 없음

다운로드

Manuals

[17320] User Manual
Unical 9000/Protos II 4400
Version 01
[14190] User Manual
ZU 0741 (PFA, PVDF, PTFE)
Chemical Pump for Probe Controllers Uniclean 900(X), Unical 9000(X)
Version 03
[14286] User Manual
ZU 0812/*, ZU 1067/*
ZU 0812/* Multiplug Bottom Section Conversion Kit / ZU 1067/* Multiplug Middle Section Conversion Kit
Version 02
[14145] User Manual
ZU 0741/1 (PTFE, stainless steel (1.4408, 1.4401)
Chemical Pump for Probe Controllers Uniclean 900(X), Unical 9000(X)
Version 04

데이터 시트

[3998] Data sheet
Unical 9000
Product Description | Specifications | Product Range

인증서

[13931] EU Declaration of Conformity (DE, EN, FR)
No. EU230413B | 2023-04-21
Unical 9000-N | Uniclean 900-N

서비스

Lorem lorem ipsum ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet. Lorem ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet.

프로세스 또는 애플리케이션에서 사용

Measuring of pH in pre-Scrubber, in neutralization and in lime scrubber within the flue gas desulfurization process in power plants.

관련 제품

관련 블로그 게시물

Uniclean 700 Series - Modular control system for automated sensor cleaning

With the Uniclean 700 series, Knick is introducing a modular control system, that can be installed very quickly and cost-effectively as a flexible entry-level solution for automated sensor cleaning.

Knick Austria - direct customer contact in Austria from 2024

Reorganization of sales in Austria and new contacts in the field of process analytics and interface technology

Robust WA111 Retractable Fitting Made of Plastic for Highly Corrosive Operating Conditions

The plastic WA111 retractable fitting is a robust and cost-effective solution for corrosive processes and environments. It is equipped with a secure lock function and multiple nozzles for thorough sensor cleaning.

Successful joint project : Knick developed the special Ceramat WA 155 retractable fitting for optical probes from SOPAT

In cooperation with SOPAT, Knick developed a special Ceramat fitting for optical probes for automatic cleaning in fouling processes.

pH and conductivity measurement in vaccine production

Pharmaceutical contract manufacturer relies on Knick's transmitters for modular production plants for Covid-19 vaccines.