A20400 Isolated Standard Signal Conditioner | Input 0(4) … 20 mA | Isolation up to 600 V | Load stop function

Description

A20400 Isolated Standard Signal Conditioner | Input 0(4) … 20 mA | Isolation up to 600 V | Load stop function

The first decoupled passive isolator with load stop function to provide protective separation of 0(4) ... 20 mA standard signals.

  • Extremely compact design
    up to 320 channels per meter
  • 1- and 2-channel versions
    cheap and flexible for a wide range of applications
  • Galvanic isolation
    between the input and output protection against incorrect measurements or damage to the equipment due to parasitic voltages
  • Protective separation up to 300 V AC/DC according to EN 61140
    to protect personnel and equipment
  • Load stop function prevents feedback
    e.g. in the case of an open output circuit
  • No power supply required
    Cost saving due to lower wiring effort no mains interference, no unnecessary self-heating and therefore maximum component service life
  • High accuracy
    No distortion of the measurement signal
  • Maximum reliability
    No repair and failure costs
  • International use
    UL / CSA approvals
  • 5-year warranty

Thanks to an extremely high packing density of up to 320 channels per meter of mounting rail and outstanding technical properties such as protective separation, these isolators leave the competition in the dust – even when it comes to the price-performance ratio!

The A20400 draws its power as a voltage drop directly from the measurement signal without falsifying it. There are no costs for a power supply and wiring. The A20400 has virtually no self-heating that would cause the electronic components to age faster. Together with a patented circuit design, this means maximum reliability. The consequence of this extraordinary long service life: 5-year warranty!

我们期待您的来信
联系我们

技术细节

AC/DC 电位隔离: 最高 600 V
工作环境 温度: –20 … 65 °C
功能: 传输/隔离标准信号
输入: 0 ... 20 mA, 4 ... 20 mA
输出: 0 ... 20 mA, 1:1 传输, 4 ... 20 mA
最小测试电压: 2.5 kV AC
电源: 无辅助电源
截止频率: 约 100 Hz
尺寸(宽 x 长 x 高): 6.2 x 93 x 101 mm
特点: 可靠性高:MTBF(平均无故障时 间)为 1,031 年, 性价比出色, 极高的封装密度,每米安装导轨 支持 320 个通道, 首款具有负载停止功能的去耦无 源隔离器(可选)
产品类别: 通用隔离器 / 标准信号隔离器

下载

操作说明书

[861] User Manual (DE, EN)
A204**
Version 05

数据手册

[854] 数据表
A20400
产品描述 | 规格 | 产品范围

证书

[12611] DNV•GL Type Approval Certificate
No. TAA00000AX | 2021-04-06
Revision No: 2
A204**P0
[11555] Certificate of Compliance (UL)
No. 20181015-E220033; 2018-10-15 (ZT181016K)
POWER CIRCUIT AND MOTOR-MOUNTED APPARATUS
A204** and BL541

Software

[12154] Software (.zip)
ePLAN P8 Produktmakros
[11876] Knick Produktmakros (.pdf)
ePLAN Electric P8

我们的服务

在工艺或应用中使用

高压隔离放大器和变送器,用于采集和转换电流、电压、温度、转速、应变和电阻信号。
长期稳定的高压隔离放大器、变送器和信号倍增器,适用于要求苛刻的应用

相关产品

相关的博客文章

Stack and String Voltage Measurement in Electrolyzers and Fuel Cells

Voltage, current and temperature measurement in electrolyzers with P40000 series high voltage transducers

适用于 Knick 变送器的新型 30 mV 分流电阻

Knick 从现在起为其高压变送器的附件产品系列增添具有 30 mV 电压降的分流电阻
Innovations at InnoTrans 2024

Innovations at InnoTrans 2024 for rolling stock and DC traction power supply

At InnoTrans 2024 Knick presents electrical measurement solutions for rolling stock and DC traction power supply applications

Knick Austria - direct customer contact in Austria from 2024

Reorganization of sales in Austria and new contacts in the field of process analytics and interface technology

Energy storage - the handshake between renewable energy and electric vehicles

Energy storage technology such as battery and hydrogen are critical for growth and continuous development of renewable energy and e-mobility.

P52000VPD 电压检测器能够可靠检测高达 4200 V 的直流电压

新型电压检测器 P52000VPD (Voltage Presence Detection) 能够可靠监控高压应用领域,在达到指定阈值时向下游设备控制器发送信号。

Knick Interface at Battery and Electric & Hybrid Vehicle Technology Expo

Knick will be showcasing high-voltage electrical measurement and signal conversion products.

VariTrans A20340 – 仅需一个隔离放大器的标准信号倍增

The A20340 can output a standard input signal to four calibrated and galvanically isolated outputs in parallel.

Electrical measurement and process analytics for hydrogen production

Knick products optimize hydrogen production in the process and in electrolyser operation.

Condition Monitoring of High-Voltage Motors

Having an active predictive maintenance campaign in place for large rotating equipment can be a key strategy for maximizing process uptime.

Pulse frequency conditioner for speed sensors

The new P16000 from Knick is a pulse frequency conditioner that converts frequency signals from speed sensors into standard signals.

全球最小传感器,高达±2200 V

Knick的VariTrans P 40000系列能对从±50 mV到±3600 V的电压,以及从±100 mA到±20 kA的电流进行可靠测量。经过验证的ProLine系列现在已经扩展到包含传感器P42000D2,它安装在Din导轨上,模块设计紧凑,测量高达2200 V的直流电压。

宽范围电源对于直流电气测量的重要性

Knick生产的众多直流电气测量产品都包含通用的,也称为宽范围电源。这意味着它们将工作在一个相对较宽的电压范围窗口内,如20…253V,交流或直流。

Measuring Photovoltaic Degradation

Photovoltaic (PV) array degradation is an important aspect to consider for system design and installation.

Electrical Measurement Solutions: Control from 480 to 4800 Volts

Voltage and current transducers from Knick bring true control to electrical measurement applications across a wide-range of industries.

Benefits of High Voltage Transducers versus Instrument Transformers

When a need arises to step voltage in a circuit either up or down for purposes of power transmission or distribution, there is no doubt that transformers are essential.

分流器和霍尔效应的技术对比

在许多系统中,为了确保性能和安全,需要测量较大的直流电流。两个例子是静态励磁和轨道牵引动力。这些电流的测量通常采用两种主要原理之一:配有mV级变送器的分流器电阻或霍尔效应传感器来反馈。

MTBF beyond 3000 years: A snap hook for your plant

Failure of equipment on the plant floor can lead to considerable and costly disruption.

Knick Products Comply With UL - What Does That Mean?

There are different assessments and approaches to reach an adequate level of safety. Manufacturers are typically on the “safe” side, if they comply with recognized standards.

High-voltage transducer offers more safety on railway vehicles

The requirements placed on railway vehicles have increased significantly in recent years. Products for rolling stock need to ensure a higher level of functional safety than ever before.

True RMS Measurement with P41000TRMS

Traditional millivolt AC transducers are very susceptible to errors due to their poor insulation and are only designed for pure sinewave measurement.

Functional safety and maximum availability can go together

The requirements on operational and safety-related circuits are continuously growing.