Skip to main content

MemoRail A1401 Compact Multiparameter Transmitter | Memosens Sensors | Ex | 1x 4…20 mA Passive Output | 24 V DC Power Supply

Description

MemoRail A1401 Compact Multiparameter Transmitter | Memosens Sensors | Ex | 1x 4…20 mA Passive Output | 24 V DC Power Supply

MemoRail A 1401 is the first genuinely compact, digital analyzer for measuring pH/ORP, conductivity, oxygen and temperature with Memosens and digital sensors.

Plug & Measure 
Pre-calibrated Memosens sensors reduce operating costs and maximize the availability of the measuring point.

Memosens 
Optimum availability of the measuring point is achieved by using pre-calibrated sensors with contactless Memosens technology. Calibration is no longer carried out on site but under reproducible conditions in the lab using the new MemoSuite software tool. Individual sensor data are always directly assigned to each Memosens sensor. Problems at the connector involving humidity, corrosion or even defective galvanic isolation are a thing of the past.

Compact 
The highly space-saving modular housing of the MemoRail devices is only 12.5 mm wide.

Cost-Efficient
The outstanding properties of MemoRail enable the implementation of measuring stations with low overall costs, especially in combination with modern Memosens sensors specially tailored for use with MemoRail.

Universal Use
MemoRail A1401 is an attractively priced solution in process analytics and optimally suited for use in numerous industry segments, such as chemicals, pharmaceuticals, biotechnology, food and beverage, or energy.
With its narrow modular housing, MemoRail A1401 is perfectly suited to installation in restricted spaces – e.g, in control cabinets, fermenters or in process plants.

  • 24 V DC power supply (via plug-in terminals or DIN rail bus connector)
  • 1 current output 4 to 20 mA, (passive)
  • Space-saving modular housing, 12.5 mm wide
  • Multiparameters: measurement of pH/ORP, conductivity, oxygen and temperature
  • Memosens communication
  • Simple configuration via DIP switches

 

MemoSuite – The Software Tool

Fast and User-Friendly 
The MemoSuite software allows calibrating Memosens sensors under reproducible conditions in the lab. MemoLink connects the sensors to the PC. On-site calibration under adverse ambient conditions is no longer necessary. The only thing required there is the quick and uncomplicated replacement of the used sensors with pre-calibrated sensors.

Two Versions 
MemoSuite Basic and MemoSuite Advanced meet different application-specific requirements:

MemoSuite Basic 
calibrates Memosens sensors.

MemoSuite Advanced 
not only performs a calibration, but also provides diagnostics and database documentation of the sensors. The database meets the requirements of GMP and FDA CFR 21 Part 11.

我们期待您的来信
联系我们

技术细节

2 或 4 线: 4 线制
permanently installed / portable: permanently installed
产品系列: MemoRail
传感器连接: Memosens
外壳: PA 66
是否防爆: UL Class I, Div. 2
测量参数: pH/ORP, 多参数, 氧, 电导率(接触式)
电流输出: 1 x 4…20 mA, passive
通信(输出,数字): 模拟 4-20 毫安
通道: 1 个通道

下载

操作说明书

[166] User Manual
MemoRail A 1401
Version 02

小册子

[13209] Brochure
Memosens - The complete solution for smart sensor applications.

数据手册

[14392] Data sheet
MemoRail A1401
Product Description | Specifications | Product Range

证书

[9246] Certificate of Compliance (UL)
Series MemoRail Type A1401x-P1-yz
PROCESS CONTROLL EQUPMENT, ELECTRICAL
No. E340287 | 2022-06-02
[14291] EU Declaration of Conformity (DE, EN, FR)
No. EU181112A | 2018-11-12
MemoRail Type A1401B-...

我们的服务

在工艺或应用中使用

测量锅炉给水中的 pH 值、溶解氧和电导率,发电厂联合循环燃气轮机中的蒸汽和冷凝水。
在 CIP/SIP 过程的极端温差下可靠测量电导率

相关产品