Skip to main content

Stratos Pro A201 COND Conductivity Transmitter | Analog Sensors | Ex Zone 2 | HART | 4 ... 20 mA Output

Description

Stratos Pro A201 COND Conductivity Transmitter | Analog Sensors | Ex Zone 2 | HART | 4 ... 20 mA Output

2-wire analyzer for conductivity measurement

  • Operation in hazardous areas
  • Digital communication: HART 
  • Intuitive operation with color-coded user guidance
  • IP 66/67, NEMA 4X protection
  • Automatic sensor identification
  • Sensor diagnostic with wear indication, remaining lifetime, CIP/SIP counter and adaptive calibration timer
  • High-contrast widescreen display with colored backlighting
  • Protective pane made of safety glass
  • One analog input (4 ... 20 mA) e.g. for external pressure compensation
  • Two parameter sets
  • Two digital inputs: 
    • External HOLD activation
    • External switching between parameter set
  • Logbook (200 entries)
Outstanding properties
A number of outstanding technological properties make the Stratos Pro series the new benchmark for 2-wire analyzers. Colored screen backlighting has been implemented for the first time in this device class, with the lowest possible power consumption.
 
Wide Range of Functions
2 digital inputs are provided, as well as an analog input plus a second current output for another measured value. 

我们期待您的来信
联系我们

技术细节

2 或 4 线: 2 线制
permanently installed / portable: permanently installed
产品系列: Stratos, Stratos Pro
传感器连接: 模拟
外壳: Molded enclosure, PBT/PC, glass-reinforced
是否防爆: Ex, Ex Zone 2
显示器: 带彩色背光的显示器
测量参数: 电导率(接触式)
电流输出: 1x 4 … 20 mA
通信(输出,数字): HART
通道: 1 个通道

下载

操作说明书

[3945] 操作说明书
Stratos Pro A201 COND
使用导电式传感器进行电导率测量
Version 04
[13527] Transmitter Specific HART Command Specification
Stratos Pro A201 Cond / A401 Cond
Device Revision: 2
[13532] Transmitter Specific HART Command Specification
Stratos Evo A402 Cond / Stratos Pro A201 Cond
Device Revision: 5 (A402) & 3 (A201 Cond)
[17264] Transmitter Specific HART Command Specification
Stratos Pro A201 Cond
Device Revision: 4

小册子

[14695] Brochure
Stratos Pro
2-wire analyzers for pH/ORP, conductivity or oxygen

数据手册

[16180] Data sheet (EN)
Stratos Pro A201
Product Description | Specifications | Product Range

证书

[9523] Certitficate of Conformity (China - Ex NEPSI)
Cert No. GYJ20.1053X | 2020-06-10
Stratos Pro A2..B
[17027] EU Type-Examination Certificate
No. KEMA 08ATEX0100 | 2024-03-07
Issue No. 10
Stratos Pro Types A201X…, A201X-*-0-T6, A211X…, A221X… and A231X… | Stratos Multi Type E401X
[8040] Certificate of Conformity (FM-Canada)
No. FM21CA0052 (Canada) | 2021-11-01
Stratos Pro Types A201X…, A211X…, A201B…, A221X… and A231X… | Stratos Multi Type E401X
[17021] IECEx Certificate of Conformity
No. IECEX KEM 08.0020
Issue No. 9 | 2024-03-07
Stratos Pro Types A201X…, A201X-*-0-T6, A211X…, A201B…, A221X…, A231X | Stratos Multi Type E401X
[8682] Certificate of Compliance (FM)
No. FM21US0078 | 2023-11-02
Stratos Multi E401X…, Stratos Pro A201X…, A211X…, A201B…, A221X…, A231X
[12917] Quality Control Certificate
Device Settings for Customer-Specific Buffer Solutions
Version 01

Safety guides

[7598] Safety Guide
Stratos Pro / MS / Evo Series
Installation and Use in Hazardous Locations
Version 05

控制图纸

[13023] Control Drawing
Stratos Pro Types A201X..., A211X..., A201B...
Zeichnungsnummer 212.002-100 page 1 rev.8
ATEX, IECEx
[13028] Control Drawing
Stratos Pro Type A20.X... or A21.X... | A20.B... or A21.B...
Zeichnungsnummer 212.110-066 page 2 rev.0
cFMus

Software

[13522] EDD (AMS)
Stratos Pro A201 Cond
Device Revision 03
[17246] EDD (AMS)
Stratos Pro A201 Cond
Device Revision 04
[12228] EDD (AMS)
Stratos Pro A201 Cond
Device Revision 02
[13517] EDD (PDM)
Stratos Pro A201 Cond
Device Revision 03
[17252) EDD (PDM)
Stratos Pro A201 Cond
Device Revision 04
[12216] EDD (PDM)
Stratos Pro A201 Cond
Device Revision 02
[13512] DTM (Pactware)
Stratos Pro A201 Cond
Device Revision 03
[17258] DTM (Pactware)
Stratos Pro A201 Cond
Device Revision 04
[12220] DTM (Pactware)
Stratos Pro A201 Cond
Device Revision 02
[18054] Software
KnUT (Knick Update Tool)

我们的服务

在工艺或应用中使用

冷却塔在各种不同的工业领域用于从冷却循环系统中排出过程热量。矿物沉积和腐蚀会降低效率,并导致设备部件过早磨损。

相关产品

相关的博客文章

Stack and String Voltage Measurement in Electrolyzers and Fuel Cells

Voltage, current and temperature measurement in electrolyzers with P40000 series high voltage transducers

适用于 Knick 变送器的新型 30 mV 分流电阻

Knick 从现在起为其高压变送器的附件产品系列增添具有 30 mV 电压降的分流电阻
Innovations at InnoTrans 2024

Innovations at InnoTrans 2024 for rolling stock and DC traction power supply

At InnoTrans 2024 Knick presents electrical measurement solutions for rolling stock and DC traction power supply applications

Uniclean 700 Series - Modular control system for automated sensor cleaning

With the Uniclean 700 series, Knick is introducing a modular control system, that can be installed very quickly and cost-effectively as a flexible entry-level solution for automated sensor cleaning.

Knick Austria - direct customer contact in Austria from 2024

Reorganization of sales in Austria and new contacts in the field of process analytics and interface technology